1. Important Safety Information

Please read all instructions carefully before operating the dehumidifier. Keep this manual for future reference.

  • Always connect to a grounded electrical outlet.
  • Do not operate the unit with a damaged cord or plug.
  • Ensure the unit is placed on a level, stable surface.
  • Do not block air inlets or outlets.
  • Unplug the unit before cleaning or performing any maintenance.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

2. Product Overview

The Whirlpool 20-Pint Portable Dehumidifier is designed to efficiently remove excess moisture from indoor spaces up to 1,500 square feet, helping to improve air quality and comfort.

Whirlpool 20-Pint Portable Dehumidifier, front view

Figure 2.1: Front view of the Whirlpool 20-Pint Portable Dehumidifier.

Key Features:

  • Removes up to 20 pints of moisture per day.
  • Electronic controls with LED humidistat display.
  • Two fan speeds for customized air quality.
  • Child lock function.
  • Continuous draining option (hose not included).
  • Loss of Power Protection: remembers settings after a power interruption.

3. Setup and Installation

3.1 Unpacking

Carefully remove the dehumidifier from its packaging. Retain the packaging materials for future storage or transport.

3.2 Caster Wheel Installation

The dehumidifier includes four caster wheels for easy mobility. Insert each wheel into the designated slots on the bottom of the unit until it clicks securely into place.

3.3 Placement

Place the dehumidifier on a firm, level surface in an area where the temperature will not fall below 41°F (5°C) or rise above 90°F (32°C). Ensure there is at least 8 inches (20 cm) of space around the unit for proper air circulation.

Whirlpool dehumidifier placed in a living room

Figure 3.1: Proper placement of the dehumidifier in a room.

3.4 Power Connection

Plug the power cord into a grounded 115V AC, 60Hz electrical outlet. Do not use an extension cord.

4. Operating Instructions

4.1 Control Panel

The control panel features an LED display and various buttons for setting the desired humidity level, fan speed, and timer functions.

Close-up of the Whirlpool dehumidifier control panel with LED display and buttons

Figure 4.1: Detail of the electronic control panel.

4.2 Setting Desired Humidity

  1. Press the Power button to turn on the unit.
  2. Use the Humidity Up/Down buttons to set your desired humidity level (e.g., 45% to 55% for general comfort). The unit will operate until the set humidity is reached, then cycle on and off to maintain it.

4.3 Fan Speed Selection

Press the Fan Speed button to toggle between two available fan speeds: Low and High. Higher fan speed will result in faster moisture removal.

4.4 Timer Function

The timer allows you to program the unit to turn on or off automatically after a set period (up to 24 hours). Press the Timer button and use the Up/Down buttons to set the desired duration.

4.5 Child Lock

To prevent unintended changes to settings, activate the Child Lock function by pressing and holding the Child Lock button (refer to the control panel diagram for exact button). This will disable all other buttons until unlocked.

4.6 Continuous Draining Option

For extended operation without manually emptying the water bucket, connect a standard garden hose (not included) to the continuous drain outlet on the back of the unit. Ensure the hose is sloped downwards to a low-level drain to allow gravity to remove collected water.

4.7 Loss of Power Protection

In the event of a power outage, the unit will automatically resume operation with the last saved settings once power is restored.

5. Maintenance

5.1 Emptying the Water Bucket

When the water bucket is full, the unit will automatically shut off and an indicator light will illuminate. Carefully remove the bucket from the front of the unit and empty the collected water. Reinsert the bucket securely to resume operation.

5.2 Cleaning the Air Filter

The dehumidifier is equipped with a removable, easy-to-clean air filter. A 'Clean Filter' alert will indicate when cleaning is required. Regular cleaning ensures optimal performance and air quality.

  1. Unplug the dehumidifier from the power outlet.
  2. Locate the filter access panel on the side or back of the unit.
  3. Gently pull out the air filter.
  4. Wash the filter with warm, soapy water. Rinse thoroughly and allow it to air dry completely before reinserting.
  5. Once the filter is dry, slide it back into its slot and close the access panel.
Side view of the Whirlpool dehumidifier with the air filter removed for cleaning

Figure 5.1: Accessing the removable air filter for cleaning.

5.3 Cleaning the Unit Exterior

Wipe the exterior of the dehumidifier with a soft, damp cloth. Do not use harsh chemicals or abrasive cleaners.

6. Troubleshooting

Before contacting customer service, please refer to the following troubleshooting guide for common issues.

ProblemPossible CauseSolution
Dehumidifier does not turn on.No power; power cord unplugged; full water bucket.Ensure unit is plugged into a live outlet; check circuit breaker; empty water bucket.
Unit runs but does not dehumidify.Air filter clogged; room temperature too low; humidity setting too high.Clean air filter; ensure room temperature is above 41°F (5°C); lower desired humidity setting.
Water leaks from the unit.Water bucket not properly seated; continuous drain hose improperly connected or blocked.Ensure water bucket is fully inserted; check continuous drain hose for proper connection and clear any blockages.
Unit is noisy.Unit not on a level surface; fan obstruction.Place unit on a firm, level surface; check for any obstructions in the fan area.

7. Specifications

Detailed technical specifications for the Whirlpool 20-Pint Portable Dehumidifier.

Whirlpool dehumidifier with dimensions labeled: 20 inches height, 15 inches width, 11 inches depth

Figure 7.1: Dehumidifier dimensions.

FeatureDetail
Model NameWhirlpool 20-Pint Portable Dehumidifier
Model NumberWHAD201CW
Dehumidification Capacity20 pints per day
Recommended AreaUp to 1500 square feet
Tank Volume14 pints
Product Dimensions (D x W x H)10.63" x 14.57" x 19.88"
Item Weight31.8 pounds
Voltage115V
Wattage260 watts
Air Flow Capacity118 cfm
Number of Speeds2
MaterialPlastic
Included ComponentsDehumidifier, 4 caster wheels, manual, warranty card

8. Warranty and Support

8.1 Warranty Information

This Whirlpool dehumidifier comes with a 1 Year Limited Warranty. Please refer to the included warranty card for full terms and conditions.

8.2 Customer Support

For technical assistance, troubleshooting not covered in this manual, or warranty claims, please contact Whirlpool customer support. Contact information can be found on the Whirlpool official website or your warranty card.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.