1. Introduction
This manual provides essential information for the installation, operation, and maintenance of the Raypak Ignition Board Kit, Part Number 018857F. This kit is specifically designed for use with the Raypak Avia Gas-Fired Pool and Spa Heater, Model 264. It serves as a critical component for controlling and monitoring your pool or spa heating system, enabling efficient and reliable performance. Please read this manual thoroughly before proceeding with installation or operation.
2. Safety Information
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment.
- Installation and service must be performed by a qualified installer, service agency, or gas supplier.
- Always disconnect all electrical power to the heater before installing or servicing the ignition board. Failure to do so can result in electrical shock, injury, or death.
- Ensure all wiring connections are secure and comply with local electrical codes.
- Do not operate the heater if any part has been submerged in water. Contact a qualified service technician to inspect the heater and replace any part of the control system and any gas control that has been submerged in water.
- Keep the area around the heater clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
3. Package Contents
Verify that all components are present and undamaged before beginning installation.
- Raypak Ignition Board (Part No. 018857F)
- Installation Guide (this document)
- Any necessary mounting hardware (if applicable, check packaging)
4. Installation Instructions
This procedure requires electrical and technical knowledge. If you are not comfortable performing these steps, please contact a qualified service technician.
4.1 Tools Required
- Screwdriver set (Phillips and flathead)
- Needle-nose pliers
- Multimeter (for verification, optional but recommended)
4.2 Step-by-Step Installation
- Disconnect Power: Locate the main power supply to the pool/spa heater and turn it OFF at the circuit breaker. Verify power is off using a multimeter.
- Access Control Panel: Open the heater's control panel cover to expose the existing ignition board. Refer to your heater's specific manual for panel access instructions.
- Document Connections: Before disconnecting any wires, take clear photographs of all wire connections to the existing ignition board. This will serve as a reference for reconnecting the new board. Label wires if necessary.
- Disconnect Wires: Carefully disconnect all wires and harnesses from the old ignition board. Note the position of each connector.
- Remove Old Board: Unscrew any mounting screws or release clips holding the old ignition board in place. Carefully remove the old board.
- Install New Board: Position the new Raypak Ignition Board (018857F) in the same location as the old board. Secure it with the original mounting screws or clips. Ensure it is seated firmly.

Figure 1: Top view of the Raypak Ignition Board (018857F) showing various connectors and components.
- Reconnect Wires: Using your photographs and labels as a guide, carefully reconnect all wires and harnesses to the corresponding terminals on the new ignition board. Ensure all connections are snug and correct.

Figure 2: Angled top view of the Raypak Ignition Board (018857F) highlighting connection points.
- Close Control Panel: Once all connections are verified, close and secure the heater's control panel cover.
- Restore Power: Turn the main power supply to the heater back ON at the circuit breaker.
- Test Operation: Follow the operating instructions for your Raypak Avia heater to test the new ignition board. Observe for proper ignition and heater function.
5. Operating the Heater with the New Board
The Raypak Ignition Board 018857F is an internal control component. Its operation is integrated with the overall control system of your Raypak Avia Model 264 heater. Once installed, the board facilitates the ignition sequence and manages various heater functions, including temperature regulation and safety shutdowns.
To operate your heater, refer to the user manual provided with your Raypak Avia Model 264 heater. The ignition board enables the heater's control panel to:
- Initiate the heating cycle.
- Monitor water temperature.
- Control gas valve operation for ignition and flame maintenance.
- Manage safety features and display error codes if issues arise.
- Allow for monitoring and control of one additional accessory, as supported by the Avia system.
6. Maintenance
The ignition board itself requires minimal direct maintenance. However, proper care of the overall heater system contributes to the longevity of all components, including the board.
- Keep Dry: Ensure the heater's control panel and internal components remain dry. Moisture can damage electronic circuits.
- Clean Connections: Periodically, with power disconnected, inspect wire connections for corrosion or looseness. Clean as necessary.
- Professional Inspection: It is recommended to have your pool/spa heater professionally inspected and serviced annually to ensure all components, including the ignition board, are functioning correctly.
7. Troubleshooting
If your heater is not functioning correctly after installing the new ignition board, consider the following common issues:
- No Power to Heater:
- Check the circuit breaker for the heater.
- Ensure all power connections to the board are secure.
- Heater Not Igniting:
- Verify all wire connections to the ignition board are correct and secure, especially those related to the igniter and flame sensor.
- Check for proper gas supply to the heater.
- Consult your heater's manual for specific error codes displayed on the control panel.
- Intermittent Operation:
- Loose connections can cause intermittent issues. Recheck all wiring.
- Ensure the board is securely mounted and not vibrating.
- Error Codes:
- Refer to your Raypak Avia Model 264 heater's user manual for a complete list of error codes and their corresponding troubleshooting steps. The ignition board communicates these codes to the heater's display.
If troubleshooting steps do not resolve the issue, contact a qualified service technician or Raypak customer support.
8. Specifications
| Product Name | Raypak Ignition Board Kit |
| Part Number | 018857F |
| Compatibility | Raypak Avia Gas-Fired Pool and Spa Heater, Model 264 |
| Product Dimensions | 8 x 5 x 1 inches |
| Item Weight | 8 ounces |
| Material | Plastic, Electronic Components |
| Manufacturer | Raypak |
| ASIN | B0D69GJMT5 |
| UPC | 840328400027 |
9. Warranty and Support
For information regarding the warranty of your Raypak Ignition Board Kit (018857F), please refer to the warranty documentation included with your original Raypak Avia heater or visit the official Raypak website. Warranty terms and conditions may vary.
For technical support, replacement parts, or service inquiries, please contact Raypak Customer Service or an authorized Raypak service center. Contact information can typically be found on the Raypak website or in your heater's primary manual.
Raypak Official Website: www.raypak.com