1. Introduction
The TESMEN TMM-569A is a smart digital multimeter designed for accurate and versatile electrical measurements. It features automatic range selection and TRUE RMS 4000 counts, making it suitable for a wide array of applications. This manual provides essential information for safe and effective operation of your multimeter.
2. Package Contents
Upon opening the package, verify that all items listed below are present and undamaged:
- TMM-569A Smart Digital Multimeter x 1
- Test Leads x 2 (Red and Black)
- Thermocouple x 1
- Storage Bag x 1
- AAA Batteries x 3
- User Manual x 1

3. Safety Information
This multimeter is designed with user safety as a priority. Adhere to all safety precautions to prevent electric shock or damage to the device. The TMM-569A meets CAT III 1000 V and CAT IV 600 V safety standards.
- Always inspect the multimeter, test leads, and accessories for any damage before use. Do not use if damaged.
- Ensure the rotary switch is set to the correct function and range before connecting test leads to the circuit.
- Do not exceed the maximum input values for any range.
- Wear appropriate personal protective equipment (PPE), such as safety glasses and insulated gloves, when working with electrical circuits.
- Avoid touching exposed wiring or circuit components during measurements.
- The device features dual fuse protection and a robust rubber sleeve for enhanced safety.

4. Product Overview
The TMM-569A Digital Multimeter is equipped with a clear backlit LCD screen and an intuitive rotary switch for function selection.
4.1. Display and Controls
- LCD Display: Backlit screen for clear visibility in various lighting conditions. Displays 4000 counts and TRUE RMS readings.
- Rotary Switch: Used to select measurement functions such as Voltage (AC/DC), Current (AC/DC), Resistance, Continuity, Diode, Capacitance, Temperature, NCV, Live Wire, and Phase.
- FUNC Button: Toggles between different measurement types within a single rotary switch position (e.g., AC/DC voltage, Resistance/Continuity/Diode/Capacitance).
- HOLD Button: Freezes the current reading on the display for easy recording.
- REL Button: Activates the relative measurement function, displaying the difference between a stored value and the current measurement.
- Backlight/Flashlight Button: Activates the display backlight and the integrated flashlight for use in dimly lit environments.

5. Setup
5.1. Battery Installation
- Locate the battery compartment cover on the back of the multimeter.
- Use a screwdriver to remove the screw securing the cover.
- Insert three AAA batteries, ensuring correct polarity (+/-).
- Replace the battery compartment cover and secure it with the screw.
5.2. Connecting Test Leads
- Insert the black test lead into the "COM" (Common) input jack.
- For most voltage, resistance, continuity, diode, capacitance, and temperature measurements, insert the red test lead into the "INPUT" jack (VΩmA).
- For current measurements (up to 400mA), use the "400mA" jack. For higher current measurements (up to 10A), use the "10A" jack. Always ensure the correct jack is used for the intended measurement.
6. Operating Modes
The TMM-569A offers a variety of measurement functions accessible via the rotary switch.
6.1. Voltage Measurement (AC/DC)
- Turn the rotary switch to the "V~" (AC Voltage) or "V-" (DC Voltage) position.
- Connect the test leads across the component or circuit to be measured.
- The display will show the voltage reading. Use the FUNC button to toggle between AC and DC if needed within a combined setting.

6.2. Current Measurement (AC/DC)
- Turn the rotary switch to the "A~" (AC Current) or "A-" (DC Current) position.
- Important: Connect the multimeter in series with the circuit. Ensure the red test lead is in the appropriate current jack (400mA or 10A).
- The display will show the current reading.
6.3. Resistance, Continuity, Diode, Capacitance
- Turn the rotary switch to the "Ω" (Resistance), "Continuity", "Diode", or "Capacitance" position.
- Use the FUNC button to select the desired measurement mode if multiple are combined on one switch position.
- Connect the test leads across the component. For continuity, a beep indicates a continuous circuit.

6.4. Temperature Measurement
- Turn the rotary switch to the "°C/°F" (Temperature) position.
- Connect the thermocouple to the appropriate input jacks.
- Place the thermocouple probe at the point where temperature needs to be measured. The display will show the temperature in Celsius or Fahrenheit.
6.5. NCV (Non-Contact Voltage) & Live Wire Detection
- Turn the rotary switch to the "NCV" position.
- Bring the top of the multimeter near a live wire or electrical outlet. The device will indicate the presence of AC voltage with an audible beep and visual indicator.
- For Live Wire detection, select the "Live" function. Insert the red test lead into the live wire or socket. The display will indicate "Live" and provide an audible alert if a live wire is detected.

6.6. Phase Detection
- Turn the rotary switch to the "Phase" position.
- Follow the on-screen instructions or manual guidance to perform phase sequence testing in multi-phase electrical systems.

6.7. Special Functions (HOLD, REL, Backlight/Flashlight)
- Data Hold (HOLD): Press the HOLD button to freeze the current measurement on the display. Press again to release.
- Relative Measurement (REL): Press the REL button to store the current reading as a reference. Subsequent measurements will display the difference from this reference. Press again to exit.
- Backlight & Flashlight: Press the backlight/flashlight button to illuminate the display or activate the integrated flashlight for working in low-light conditions.

7. Maintenance
- Cleaning: Wipe the multimeter with a dry, soft cloth. Do not use abrasive cleaners or solvents.
- Storage: Store the device in its provided storage bag in a cool, dry place away from direct sunlight and extreme temperatures.
- Battery Replacement: Replace batteries when the low battery indicator appears on the display to ensure accurate measurements.
- Fuse Replacement: If a fuse blows, replace it with a fuse of the same type and rating as specified in the specifications section. Refer to the safety information for proper access.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No display or faint display | Low or dead batteries | Replace the AAA batteries. |
| "OL" (Overload) displayed | Measurement range exceeded or open circuit | Select a higher range or check for an open circuit. |
| Incorrect readings | Incorrect function/range selected, poor test lead connection, or damaged leads | Verify settings, ensure secure connections, or replace test leads. |
| No continuity beep | Open circuit or component resistance too high | Check the circuit for breaks or measure resistance directly. |
9. Specifications
| Feature | Detail |
|---|---|
| Model | TMM-569A |
| Display Counts | 4000 Counts |
| True RMS | Yes |
| Safety Rating | CAT III 1000 V, CAT IV 600 V |
| Power Source | 3 AAA batteries (included) |
| Dimensions | 20.9 x 13.6 x 6.9 cm |
| Item Weight | 0.69 Kilograms |
| Upper Temperature Rating | 150 Degrees Celsius |
| Auto-Off Function | Yes (after period of inactivity) |
| Data Hold | Yes |
| Relative Measurement (REL) | Yes |
| Backlight & Flashlight | Yes |