1. Important Safety Information
Please read all instructions carefully before installing or operating your Friedrich Chill Premier Inverter air conditioner. Retain this manual for future reference.
WARNING: Risk of Fire or Explosion
- Store in a well-ventilated area without continuously operating flames or other potential ignition sources.
- Do not pierce or burn.
- Be aware that refrigerants may not contain an odor.
- Only qualified personnel should perform service on this unit.
Electrical Safety: Ensure the unit is connected to a properly grounded outlet with the correct voltage (115V). Do not use extension cords. Disconnect power before servicing.
Installation Safety: Follow all local and national electrical codes. Ensure the unit is securely installed to prevent falling. Do not block air vents.
General Precautions: Keep children and pets away from the unit during operation. Do not insert objects into the air vents. Do not operate with a damaged power cord or plug.
2. Product Overview
The Friedrich Chill Premier Inverter is a high-efficiency window and wall air conditioning unit designed for precise temperature control and quiet operation. It features advanced inverter technology and is Energy Star certified, offering significant energy savings.

Figure 2.1: Front view of the Friedrich Chill Premier Inverter unit.
This image displays the front of the Friedrich Chill Premier Inverter air conditioner, highlighting its sleek design, digital temperature display, and intuitive control buttons located above the main air intake grille.
Key Features:
- Precision Inverter Technology: Provides efficient, precise temperature control and "Library-Quiet" sound levels.
- Energy Star Certified: Up to 35% more efficient than other window air conditioners.
- SimpleSill™ Design: Allows windows to be opened and closed after unit installation for fresh air.
- Smart Wi-Fi Control: Control the unit from anywhere using the FriedrichGo™ app, compatible with Amazon Alexa and Google Assistant.
- Washable Air Filter: Easy to clean for optimal performance.
- Money Saver® Mode & Sleep Mode: Optimize energy consumption and comfort.
- Auto Air Sweep: Ensures even air distribution.

Figure 2.2: Precise performance and quiet comfort.
This image illustrates the quiet operation and precise performance of the Chill Premier Inverter, showing a couple comfortably enjoying their living space with the unit in the background.
3. Setup and Installation
The Friedrich Chill Premier Inverter unit is designed for simplified installation in both window and through-the-wall applications. Always ensure proper support and sealing to maximize efficiency and prevent water intrusion.
3.1 Window Installation
The unit features a three-step window installation process with a one-piece frame, simplifying setup. The unique SimpleSill™ Design allows you to open and close your window even after the unit is installed, providing flexibility for fresh air when cooling is not needed.
- Prepare the window opening according to the dimensions provided in the specifications.
- Assemble the one-piece frame and securely mount it in the window.
- Carefully slide the air conditioner unit into the installed frame.
- Secure the unit and seal any gaps to prevent air leakage.
- Ensure the unit is slightly tilted outwards to allow for proper condensate drainage.

Figure 3.1: Easy three-step window installation.
This image demonstrates the Friedrich Chill Premier Inverter unit seamlessly installed in a window, showcasing its adaptable design within a typical living room environment.
3.2 Wall Installation
For through-the-wall installation, a wall sleeve (sold separately) is typically required. Consult the detailed installation guide provided with the wall sleeve for specific instructions and structural requirements.
- Ensure the wall opening is properly sized and reinforced to support the unit's weight.
- Install the wall sleeve according to its instructions, ensuring it is level and sealed.
- Slide the air conditioner unit into the wall sleeve.
- Secure the unit and apply weather stripping or sealant around the edges to prevent drafts and moisture.

Figure 3.2: SimpleSill™ Design for window flexibility.
This image highlights the SimpleSill™ Design feature, showing a user easily opening a window even with the air conditioner installed, allowing for natural ventilation.
4. Operating Instructions
Your Friedrich Chill Premier Inverter unit offers various modes and settings for optimal comfort and energy efficiency.
4.1 Control Panel and Remote
The unit can be controlled via the intuitive control panel on the front of the unit or the included remote control. The digital display shows the current temperature and selected settings.
4.2 Operating Modes
- Cool Mode: Provides cooling. Set your desired temperature using the up/down arrows.
- Fan Mode: Circulates air without cooling. Choose from multiple fan speeds.
- Money Saver® Mode: Automatically cycles the fan and compressor to maintain comfort while minimizing energy use.
- Sleep Mode: Gradually adjusts temperature and fan speed for quiet, comfortable sleep and reduced energy consumption overnight.
- Auto Air Sweep: Activates the oscillating louvers to distribute cool air evenly throughout the room.
4.3 Smart Wi-Fi Control
Control your air conditioner from anywhere using the FriedrichGo™ app on your smartphone or tablet. The unit is also compatible with Amazon Alexa and Google Assistant for voice control.
- Download the FriedrichGo™ app from your device's app store.
- Follow the in-app instructions to connect your air conditioner to your home Wi-Fi network.
- Once connected, you can adjust settings, set schedules, and monitor the unit remotely.

Figure 4.1: Smart Wi-Fi Control via FriedrichGo™ app.
This image demonstrates the convenience of controlling the Friedrich Chill Premier Inverter unit remotely using the FriedrichGo™ app on a smartphone, highlighting its compatibility with smart home assistants.
5. Maintenance
Regular maintenance ensures optimal performance and longevity of your air conditioner.
5.1 Cleaning the Air Filter
The unit is equipped with a washable air filter. A dirty filter can reduce cooling efficiency and airflow. Clean the filter every two weeks or more frequently if the unit is used heavily or in dusty environments.
- Turn off the air conditioner and unplug it from the power outlet.
- Locate and remove the air filter from the front grille.
- Wash the filter with warm, soapy water. Rinse thoroughly.
- Allow the filter to air dry completely before reinstalling. Do not use heat to dry.
- Reinsert the dry filter into the unit.
5.2 Cleaning the Unit Exterior
Wipe the exterior of the unit with a soft, damp cloth. Do not use harsh chemicals, abrasives, or solvents, as these can damage the surface.
5.3 Coil Maintenance
The unit features corrosion-resistant coils, which help prolong their lifespan. Periodically inspect the outdoor coils for dirt and debris. If heavily soiled, professional cleaning may be required to maintain efficiency.

Figure 5.1: Rear view showing condenser coils.
This image provides a view of the rear of the air conditioner, revealing the condenser coils which are crucial for heat exchange and cooling performance.
6. Troubleshooting
Before contacting customer service, try the following troubleshooting steps for common issues.
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on. | No power, tripped circuit breaker, unit unplugged. | Ensure unit is plugged in. Check circuit breaker and reset if tripped. Verify power outlet is functional. |
| Unit is making a loud noise. | Loose parts, fan obstruction, unit not level, internal component issue. | Check for loose screws or panels. Ensure no objects are obstructing the fan. Verify the unit is level. If noise persists, contact customer support. |
| Insufficient cooling. | Dirty air filter, blocked air vents, room too large, temperature setting too high. | Clean the air filter. Ensure air intake and exhaust vents are clear. Verify room size is within unit capacity. Lower the temperature setting. |
| Water leakage. | Unit not tilted correctly, clogged drain pan/hose. | Ensure the unit is slightly tilted outwards for proper drainage. Check and clear any blockages in the drain pan or hose. |
If the problem persists after attempting these solutions, please contact Friedrich customer support.
7. Specifications
| Attribute | Value |
|---|---|
| Brand Name | Friedrich |
| Model Info | CCV15A10A |
| Cooling Power | 15,000 British Thermal Units (BTU) |
| Voltage | 115 Volts |
| Wattage | 1600 watts |
| Item Weight | 100 pounds |
| Product Dimensions (D x W x H) | 26 x 26 x 17 inches |
| Noise Level | 42 dB |
| Capacity | 423 Cubic Feet |
| Installation Type | Window or Wall-mounted |
| Refrigerant Type | R-32 |
| Seasonal Energy Efficiency Ratio (SEER) | 14.4 |
| Energy Star Certified | Yes |
8. Warranty and Customer Support
This Friedrich Chill Premier Inverter unit is covered by a manufacturer's warranty. Please refer to the warranty card included with your product for specific terms, conditions, and duration. Keep your proof of purchase for warranty claims.
For technical assistance, troubleshooting beyond this manual, or warranty service, please contact Friedrich customer support. Contact information can typically be found on the manufacturer's website or on the product packaging.
Online Resources: Visit the official Friedrich website for FAQs, updated manuals, and support resources.