1. Introduction
This manual provides comprehensive instructions for the safe and efficient operation, installation, and maintenance of your Bunn 38700.0008 Axiom-DV-3 Dual Voltage Coffee Brewer. Please read this manual thoroughly before operating the appliance and retain it for future reference. This brewer is designed for commercial use, offering advanced features for consistent coffee quality.
2. Safety Information
Important Safety Instructions:
- Read all instructions before using the appliance.
- Do not touch hot surfaces. Use handles or knobs.
- To protect against fire, electric shock, and injury to persons, do not immerse cord, plugs, or appliance in water or other liquid.
- Close supervision is necessary when any appliance is used by or near children.
- Unplug from outlet when not in use and before cleaning. Allow to cool before putting on or taking off parts, and before cleaning the appliance.
- Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions, or has been damaged in any manner. Return appliance to the nearest authorized service facility for examination, repair, or adjustment.
- The use of accessory attachments not recommended by the appliance manufacturer may result in fire, electric shock, or injury to persons.
- Do not use outdoors.
- Do not let cord hang over edge of table or counter, or touch hot surfaces.
- Do not place on or near a hot gas or electric burner, or in a heated oven.
- Always attach plug to appliance first, then plug cord into the wall outlet. To disconnect, turn any control to 'off', then remove plug from wall outlet.
- Do not use appliance for other than intended use.
- WARNING: Warmers and surfaces are hot. Exercise caution to prevent burns.
- Proposition 65 Warning: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
3. Product Overview
The Bunn Axiom-DV-3 is a high-performance dual voltage coffee brewer designed for commercial environments. It features a robust stainless steel construction and advanced brewing technologies to ensure consistent coffee quality.
Key Features:
- Dual voltage adaptable: Operates at 120V/15 amp or 120/208-240V/20 amp.
- Large 200oz. (5.9L) tank for back-to-back brewing capacity.
- Programmable pre-infusion, pulse brew, and digital temperature control for optimal coffee extraction.
- Front-accessible programming for brew level, cold brew lock-out, and tank temperature.
- Equipped with one lower and two upper warmers to keep coffee at serving temperature.
- Integrated hot water faucet for convenience.
Product Components:






4. Setup
4.1 Unpacking and Placement
- Carefully remove the brewer from its packaging.
- Place the brewer on a stable, level surface capable of supporting its weight when full. Ensure adequate clearance for ventilation around the unit.
- Inspect the unit for any shipping damage. Contact your supplier immediately if damage is found.
4.2 Electrical Connection
The Axiom-DV-3 is a dual voltage unit. It can operate at 120V/15 amp or 120/208-240V/20 amp. Ensure the electrical supply matches the brewer's configuration and local electrical codes. Connection should be performed by a qualified electrician.
4.3 Water Connection
This brewer requires a plumbed-in water supply. Connect the brewer to a cold water line with a shut-off valve. A water filter is recommended to prevent mineral buildup and ensure optimal coffee taste. Follow local plumbing codes for installation.
4.4 Initial Cleaning and Priming
- Before first use, clean the exterior with a damp cloth.
- Ensure the water supply is connected and turned on.
- Turn the main power switch (located at the rear) to the 'ON' position. The tank will begin to fill and heat water. This process may take several minutes.
- Once the display indicates 'READY TO BREW', run several cycles of hot water through the brew funnel without coffee to flush the system.
5. Operating Instructions
Note: Coffee decanters are not included and must be purchased separately.
5.1 Brewing Coffee
- Ensure the brewer is powered on and the display shows 'READY TO BREW'.
- Place a clean, empty coffee decanter on the lower warming plate.
- Insert a filter into the brew funnel.
- Add the desired amount of ground coffee to the filter.
- Slide the brew funnel into its position under the spray head.
- Press the 'BREW' button on the control panel to start the brewing cycle.
- Once brewing is complete, carefully remove the brew funnel and discard the used grounds and filter.
- Place the freshly brewed coffee decanter on an upper warmer if desired, or serve immediately.
5.2 Using the Hot Water Faucet
- Ensure the brewer is powered on and water is heated.
- Place a cup or container under the hot water faucet.
- Pull the faucet handle forward to dispense hot water.
- Push the handle back to stop the flow.
- Caution: Hot water can cause burns. Exercise care when dispensing.
5.3 Programming Settings
The Axiom-DV-3 allows for customization of brewing parameters:
- Brew Level: Adjust the volume of coffee brewed per cycle.
- Cold Brew Lock-Out: Prevents brewing if the water temperature is below optimal.
- Tank Temperature: Set the desired water temperature for brewing.
- Pre-infusion and Pulse Brew: These settings control the wetting of coffee grounds for enhanced extraction.
Refer to the on-screen menu and the specific programming guide (if provided with your unit) for detailed instructions on adjusting these settings from the front control panel.
6. Maintenance
Regular cleaning and maintenance ensure optimal performance and longevity of your coffee brewer.
6.1 Daily Cleaning
- Turn off the brewer and unplug it from the power outlet. Allow it to cool completely.
- Remove and clean the brew funnel and spray head with mild detergent and warm water. Rinse thoroughly.
- Wipe down all exterior surfaces with a damp cloth. Do not use abrasive cleaners or scouring pads.
- Clean the warming plates with a damp cloth. Ensure no coffee residue builds up.
6.2 Descaling (Periodically)
Mineral deposits can accumulate over time, affecting performance. The frequency of descaling depends on your water hardness. Consult a qualified service technician for descaling procedures or refer to Bunn's official descaling instructions.
6.3 Filter Replacement
The brewer uses paper filters for brewing. Always use a fresh filter for each brew cycle. If an inline water filter is installed for the water supply, follow the manufacturer's recommendations for its replacement.
7. Troubleshooting
This section addresses common issues you might encounter with your Axiom-DV-3 brewer.
| Problem | Possible Cause | Solution |
|---|---|---|
| Brewer does not turn on | No power, main switch off, circuit breaker tripped | Check power cord connection, ensure main ON/OFF switch (rear) is on, check circuit breaker. |
| Coffee not brewing | Water supply off, cold brew lock-out active, brew funnel not properly seated | Ensure water supply is on, check display for 'READY TO BREW' (water temperature), ensure brew funnel is fully inserted. |
| Slow brewing or weak coffee | Mineral buildup, incorrect grind size, insufficient coffee grounds | Descale the brewer (consult technician), use appropriate grind size for drip coffee, ensure correct coffee-to-water ratio. |
| Annoying beeping sounds | Alerts for brew completion or other functions | Press and hold the 'SET DELAY' button for 5 seconds until it beeps to turn off the beeping sounds. |
| Water leaks | Loose connections, damaged components | Turn off water supply and power. Inspect all connections. Contact a qualified technician for repair. |
If you encounter issues not listed here or if the suggested solutions do not resolve the problem, please contact Bunn customer support or a qualified service technician.
8. Specifications
| Feature | Specification |
|---|---|
| Brand | Bunn |
| Model Name | AXIOM-DV-3, 1L/2U PF |
| Item Model Number | 38700.0008 |
| Product Dimensions (D x W x H) | 22.1" x 8.4" x 18.9" |
| Item Weight | 30 pounds |
| Color | Silver |
| Exterior Finish | Stainless Steel |
| Voltage | 120 Volts (Dual Voltage Adaptable: 120V/15A or 120/208-240V/20A) |
| Operation Mode | Fully Automatic |
| Coffee Input Type | Ground Coffee |
| Included Components | Filter (paper filters for brewing) |
| Recommended Uses | Breakrooms, Offices, Restaurants |
| Human Interface Input | Buttons |
| Tank Capacity | 200 oz. (5.9 L) |
| UPC | 072504081434 |
9. Warranty and Support
Specific warranty details for the Bunn 38700.0008 Axiom-DV-3 Dual Voltage Coffee Brewer are typically provided with the product packaging or can be found on the official Bunn website. Please refer to these resources for the most accurate and up-to-date warranty information.
For technical support, service, or to purchase replacement parts, please contact Bunn customer service or visit the official Bunn website. You can also visit the BUNN Store on Amazon for additional product information and accessories.