1. Introduction
Thank you for choosing the Berrcom Automatic Upper Arm Blood Pressure Monitor. This device is designed for accurate and convenient measurement of systolic and diastolic blood pressure, as well as pulse rate, at home. It features a large backlit LED display, dual user memory, and an irregular heartbeat detector. Please read this manual thoroughly before use to ensure proper operation and to obtain accurate readings.
2. Important Safety Information
- Consult your physician for interpretation of blood pressure measurements. Self-diagnosis and treatment based on measurements can be dangerous.
- This device is intended for adult use only.
- Do not use this device on infants, children, or individuals who cannot express their consent.
- Do not use this device in a moving vehicle.
- Avoid eating, drinking, smoking, or exercising for at least 30 minutes before taking a measurement.
- Rest for at least 5 minutes before taking a measurement.
- If you have any concerns about your health, please consult a medical professional.
3. Package Contents
Verify that all items are present in the package:
- Berrcom Blood Pressure Monitor (FC-BP120)
- Wide Range Upper Arm Cuff (22-42cm / 8.7"-16.5")
- Instruction Manual
- Drawstring Carrying Bag
- 4 x AAA Batteries
- USB Cable (Type-C)

4. Product Overview
4.1 Main Unit and Display
The Berrcom Blood Pressure Monitor features a clear, backlit LED display and intuitive buttons for easy operation.


4.2 Cuff
The monitor comes with a comfortable, wide-range cuff suitable for upper arm circumferences from 22cm to 42cm (8.7 to 16.5 inches).

5. Setup
5.1 Power Supply
The monitor can be powered by either 4 AAA batteries or a USB-C cable.
- Battery Installation: Open the battery compartment cover on the back of the device. Insert 4 AAA batteries, ensuring correct polarity (+/-). Close the cover.
- USB-C Power: Connect the provided USB-C cable to the port on the side of the monitor and plug the other end into a compatible USB power adapter (not included) or a USB port.
Using batteries allows for portability and retains settings and memory. Using USB power without batteries will require re-setting date/time and user preferences each time the device is powered off.

5.2 Initial Settings (Date, Time, User, Voice)
After installing batteries or connecting power, the device may prompt you to set the date and time. Use the 'SET' button to enter settings mode and 'MEM' button to adjust values. Press 'SET' again to confirm and move to the next setting.
- Setting Date and Time: Follow the on-screen prompts to set the year, month, day, hour, and minute.
- Selecting User: The device supports two users (User 1 and User 2). In settings, select the desired user profile.
- Voice Broadcast: The monitor includes a voice broadcast feature. You can enable or disable this feature in the settings menu.
6. Operating Instructions
6.1 Applying the Cuff
Correct cuff placement is crucial for accurate readings.
- Sit comfortably with your back supported and feet flat on the floor.
- Place the cuff on your bare upper left arm, approximately 2-3 cm (about one finger's width) above your elbow joint. The air tube should run down the center of your arm.
- Ensure the cuff is snug but not too tight. You should be able to insert one finger between your arm and the cuff.
- Rest your arm on a table so the cuff is at the same level as your heart.

6.2 Taking a Measurement
Once the cuff is correctly applied and you are in a relaxed position:
- Press the START/STOP button. The cuff will begin to inflate automatically.
- Remain still and silent during the measurement. Avoid talking or moving your arm.
- Once the measurement is complete, the cuff will deflate, and your systolic pressure, diastolic pressure, and pulse rate will be displayed on the screen. The result will be automatically saved to the selected user's memory.
- Press the START/STOP button again to turn off the device, or it will automatically shut off after a period of inactivity.
6.3 Tips for Accurate Measurement
- Sit for at least 5 minutes before measurement.
- Wait at least 3 minutes between measurements if taking multiple readings.
- Measure at least 30 minutes after eating, bathing, or exercising.
- Do not measure within 30 minutes after exercising, smoking, or drinking alcohol.
- Do not wear thick clothes; wear a short sleeve or thin garment during measurement.
- Do not compress or restrict the air hose or the cuff when taking measurements.

6.4 Dual User Mode
The monitor supports two individual users, each with 99 memory slots. To switch between User 1 and User 2, press the 'SET' button when the device is off or in standby mode until the user icon flashes, then use the 'MEM' button to toggle between users. Press 'SET' to confirm.

6.5 Memory Functions
To view past measurements, press the MEM button when the device is off or in standby mode. Each press will cycle through the stored readings for the currently selected user, displaying systolic, diastolic, pulse, and the date/time of the measurement.
7. Understanding Your Readings
The monitor displays three key values: Systolic pressure, Diastolic pressure, and Pulse rate. It also features an Irregular Heartbeat Detector and a color-coded indicator based on WHO (World Health Organization) guidelines.
- Systolic Pressure (SYS): The top number, indicating the pressure in your arteries when your heart beats.
- Diastolic Pressure (DIA): The bottom number, indicating the pressure in your arteries between beats.
- Pulse Rate (PUL): Your heart rate, measured in beats per minute.
- Irregular Heartbeat Detector: An icon will appear on the display if an irregular heartbeat is detected during measurement. If this icon appears frequently, consult your physician.
7.1 WHO Blood Pressure Classification Indicator
The monitor provides an instant visual assessment of your blood pressure level using a color-coded indicator on the left side of the display:
- Green: Optimal/Normal Blood Pressure
- Yellow: Normal-High / Pre-Hypertension
- Red: Hypertension (High Blood Pressure)

8. Maintenance and Care
- Cleaning: Wipe the monitor and cuff gently with a soft, dry cloth. If necessary, use a slightly damp cloth with mild soap, then wipe dry. Do not use abrasive cleaners or immerse the device in water.
- Storage: Store the device in its carrying bag in a cool, dry place, away from direct sunlight, extreme temperatures, and humidity.
- Batteries: Remove batteries if the device will not be used for an extended period to prevent leakage.
- Cuff Care: Do not fold the cuff tightly or twist the air tube excessively.
9. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not turn on | Batteries are dead or incorrectly inserted; USB cable not connected properly. | Replace batteries or check polarity. Ensure USB cable is securely connected. |
| Inaccurate readings | Incorrect cuff placement; movement or talking during measurement; not resting before measurement. | Re-apply cuff correctly. Remain still and silent. Rest for 5 minutes before measuring. |
| Cuff does not inflate or inflates too little | Air tube disconnected; cuff not properly secured. | Check that the air tube is securely connected to the monitor. Ensure cuff is wrapped snugly. |
| Irregular Heartbeat Detector icon appears frequently | Indicates potential arrhythmia. | Consult your physician for further evaluation. |
10. Specifications
- Model: FC-BP120
- Measurement Method: Oscillometric
- Cuff Size: 22-42 cm (8.7"-16.5")
- Display: Backlit LED
- Memory: 2 users x 99 readings each (198 total)
- Power Source: 4 x AAA batteries (included) or USB-C (cable included, adapter not included)
- Product Dimensions: Approximately 13.39 x 9.5 x 5.16 cm
- Item Weight: Approximately 240 g
- Features: Irregular Heartbeat Detector, WHO Classification Indicator, Voice Broadcast
11. Warranty and Support
Berrcom products are manufactured with quality and reliability in mind. For warranty information or technical support, please refer to the contact details provided in the product packaging or visit the official Berrcom website. Keep your purchase receipt as proof of purchase for warranty claims.