1. Introduction
The AIRGO AC Soft Starter 08-16A is designed to reduce the in-rush current of your air conditioner's compressor during startup. This technology gently ramps up the compressor, minimizing electrical stress, extending the lifespan of your AC unit, and enabling smoother operation with alternative power sources like generators or solar inverters. This manual provides essential information for proper installation, operation, and maintenance of your AIRGO Soft Starter.
2. Safety Information
WARNING: Electrical shock hazard. Installation should only be performed by qualified personnel or a licensed electrician. Always disconnect power to the AC unit at the circuit breaker or disconnect switch before beginning any installation or maintenance procedures.
- Ensure all local and national electrical codes are followed.
- Verify the voltage and current ratings of your AC unit are compatible with the AIRGO Soft Starter model (08-16A).
- Allow at least 2 minutes for the run capacitor to discharge before disconnecting any wires.
- Do not operate the unit if any wiring appears damaged or improperly connected.
3. Product Overview
The AIRGO AC Soft Starter 08-16A is a compact device engineered for seamless integration into residential AC units. It features proprietary Reverse Motor Protection, which is crucial for systems operating with utility and/or generator power, ensuring a smooth transition and protecting the compressor.

Figure 3.1: AIRGO AC Soft Starter 08-16A unit, showing its compact design and integrated wiring diagram.
Key Features:
- Soft Start Technology: Reduces compressor startup current.
- Reverse Motor Protection: Safeguards the compressor during power transitions.
- Compact Footprint: Designed for easy installation inside AC units.
- Wide Compatibility: Suitable for 1.75-3.5 ton AC units.
- Robust Operating Range: Functions reliably from -4°F to 140°F.

Figure 3.2: Icon representing the Reverse Motor Protection feature, a key safety mechanism.
4. Installation
4.1 Pre-Installation Checklist
- Ensure you have the correct AIRGO Soft Starter model (08-16A) for your AC unit.
- Gather necessary tools: screwdriver, wire strippers, multimeter.
- Locate the AC unit's data tag to identify compressor RLA (Rated Load Amps) and LRA (Locked Rotor Amps).

Figure 4.1: Example of an AC unit data tag. Identify RLA (Rated Load Amps) and LRA (Locked Rotor Amps) for compatibility.
4.2 Determining the Correct AIRGO Model
Use the following flowchart to confirm you have the appropriate AIRGO Soft Starter for your AC unit. If your unit falls outside the 08-16A range or if you have a non-scroll compressor with an FLA/RLA greater than 20A, contact technical support.

Figure 4.2: Flowchart for selecting the correct AIRGO Soft Starter model based on compressor specifications.
4.3 Step-by-Step Installation Guide
Follow these steps carefully for a successful installation. Refer to the detailed wiring diagram and images provided.

Figure 4.3: Visual step-by-step installation instructions for the AIRGO Soft Starter.
- Receive Product: Confirm you have received your AIRGO Soft Starter and included wire kit.
- Unpack: Remove all components from the packaging.
- Prepare Wires: Organize the included wires for easy access.
- Disconnect Power: CRITICAL: Turn off power to the HVAC unit at the circuit breaker or disconnect switch. Verify power is off with a multimeter.
- Open AC Unit: Open the electrical access panel of your outdoor AC unit.
- Locate Wiring Diagram: Find the existing wiring diagram, typically on the inside of the access panel cover.
- Mount Bracket: Install the mounting bracket for the AIRGO unit in a suitable location inside the AC unit, ensuring at least 3 inches (76 mm) clearance from hot lines or discharge piping.
- Install Soft Starter: Securely mount the AIRGO Soft Starter to the bracket.
- Remove Compressor Run Wire: Disconnect the compressor's existing Run wire (often yellow, but color may vary) from the run capacitor or compressor terminal.
- Strip Run Wire: Strip the end of the compressor's original Run wire.
- Connect Brown Wire: Terminate the brown wire from the AIRGO unit to the 'C' terminal on the run capacitor.
- Connect Black Wire: Connect the black wire from the AIRGO unit to the load-side contactor terminal labeled '2' or 'T2' in a typical application.
- Connect Blue Wire: Connect the blue wire from the AIRGO unit to the 'H' terminal on the capacitor.
- Connect Red Wire: Connect the red wire from the AIRGO unit to the load-side contactor terminal labeled '1' or 'T1' in a typical application.
- Verify Wiring: Double-check all connections against the wiring diagram.
4.4 Wiring Diagram Reference
The following diagram illustrates the typical wiring connections for the AIRGO Soft Starter. Note that wire colors from your AC unit may vary.

Figure 4.4: Comprehensive wiring diagram for the AIRGO Soft Starter. Consult this diagram for precise connections.

Figure 4.5: Terminal connections on the AIRGO unit. The yellow wire's color may vary in your specific AC unit.
4.5 Mounting Considerations
The AIRGO Soft Starter features a small footprint, allowing for convenient installation directly inside most AC units. Ensure adequate clearance for ventilation and maintenance.

Figure 4.6: The compact size of the AIRGO Soft Starter facilitates installation within the AC unit's existing enclosure.
For additional installation resources and guides, visit InstallCentral.com/soft-starters.
5. Operation
Once correctly installed, the AIRGO AC Soft Starter operates automatically. When your AC unit receives a call for cooling, the soft starter will manage the compressor's startup, gradually increasing power to reduce the initial current surge. This process is typically completed within a few seconds and is designed to be seamless and unnoticed by the user, except for the quieter and smoother startup of the AC unit.
6. Maintenance
The AIRGO AC Soft Starter is designed for maintenance-free operation. However, periodic visual inspection of the unit and its wiring connections is recommended during routine AC system maintenance. Ensure all connections remain secure and free from corrosion or damage. If any issues are observed, disconnect power immediately and consult a qualified technician.
7. Troubleshooting
The AIRGO Soft Starter includes an LED indicator to assist with troubleshooting. Refer to the LED status on the product label (Figure 3.1) for diagnostic information:
| LED Status | Indication | Possible Cause / Action |
|---|---|---|
| Solid Green | Normal Operation | Unit is functioning correctly. |
| Flashing (1 sec) | Cycle Delay or Fault | Temporary delay or minor fault. Unit may reset automatically. |
| Flashing (3 sec) | Over Current | Compressor drawing excessive current. Check compressor, wiring, or contact support. |
| Flashing (5 sec) | Start Failed | Compressor failed to start. Check compressor, run capacitor, or wiring. |
| Flashing (10 sec) | Low Voltage | Input voltage is too low. Check power supply, especially during generator operation. |
If troubleshooting steps do not resolve the issue, please contact AIRGO customer support.
8. Specifications
| Specification | Value |
|---|---|
| Product Dimensions (L x W x H) | 5.3 x 2.96 x 1.96 inches |
| Item Weight | 1.08 Pounds |
| Model Number | 08-16A |
| Operation Mode | ON-OFF |
| Current Rating | 16 Amps |
| Operating Voltage | 240 Volts |
| Contact Type | Normally Open |
| Connector Type | Clamp |
| Terminal Type | Screw |
| Circuit Type | 1-way |
| Actuator Type | Push Button |
| Operating Temperature Range | -4°F to 140°F |
| Storage Temperature Range | -40°F to 185°F |
| Compliance | A2L Compliant |
9. Warranty Information
Specific warranty details are not provided in the product information. Please refer to the product packaging or contact the seller directly for warranty terms and conditions.
10. Support
For any installation questions, technical assistance, or support, please contact the seller directly. Their contact information can typically be found on your purchase receipt or the product packaging.