Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your SHARP AY-S25V-W Air Conditioner. Please read this manual thoroughly before using the product and keep it for future reference.
Safety Information
Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury to persons.
- Ensure the power supply matches the unit's requirements (100V-15A).
- Do not attempt to install or repair the unit yourself. Always consult qualified professionals for installation and servicing.
- Keep the area around the outdoor unit clear of obstructions.
- Do not insert fingers or objects into the air inlet/outlet.
- In case of abnormal operation, turn off the power immediately and contact customer support.
Product Overview
The SHARP AY-S25V-W is a V-series air conditioner designed for comfortable indoor climate control. It features both heating and cooling functions.

Figure 1: SHARP AY-S25V-W Indoor Unit. This image shows the front view of the white indoor air conditioner unit.
Key Features:
- Heating and Cooling Functionality
- Suitable for approximately 8 tatami mats (10-17 m²)
- 100V Power Supply
- Compact Indoor Unit Design
Installation
Professional installation is highly recommended for this air conditioner. The following outlines the general flow and potential additional costs associated with the installation process.
Installation Flow:

Figure 2: Flow from Purchase to Installation. This diagram illustrates the six steps of the installation process: Order, Hearing Sheet Reply, Installation Date Arrangement, Product Receipt, Contact for Visit Time, and Visit/Installation.
- Step 1: Order Placement - Place your order via the website.
- Step 2: Hearing Sheet Reply - A hearing sheet will be sent to your registered email address after your order. Please confirm and reply.
- Step 3: Installation Date Arrangement - Contact will be made via email to arrange and discuss the desired installation date.
- Step 4: Product Receipt - The product will be delivered to you before the installation date.
- Step 5: Contact for Visit Time - You will be contacted to confirm the visit time for installation.
- Step 6: Visit & Installation - The installation team will visit and complete the setup.
Standard Installation Scope:
Standard installation includes mounting the indoor and outdoor units, plastic blocks, and piping (up to 4m of piping work and tape wrapping finish). Hole drilling is free for one location in general wooden/mortar walls.
Note: Depending on your home's conditions, additional on-site charges may apply. Please confirm with the installer.
Examples of Additional Installation Costs:
The following tables provide examples of potential additional costs for specific installation scenarios.
Outdoor Unit Installation Location:

Figure 3: Additional Costs for Outdoor Unit Installation. This image shows various outdoor unit placement scenarios (rooftop, wall-mounted, ground level, veranda, two-tier) and their associated new installation and replacement costs.
| Installation Type | New Installation (from) | Replacement (from) |
|---|---|---|
| Rooftop/Wall-mounted/Ceiling-hung | ¥14,300 | ¥7,700 |
| Ground Level | ¥0 (Standard) | ¥0 (Standard) |
| Veranda Placement | ¥0 (Standard) | ¥0 (Standard) |
| Two-tier Placement | ¥19,800 | ¥3,300 |
High-altitude work (e.g., piping from 2nd to 1st floor: ¥3,300; 3rd to 1st floor: ¥7,700) may incur additional charges.
Piping Cover Work:

Figure 4: Additional Costs for Piping Cover Work. This image details costs for new indoor/outdoor covers, reusing existing covers, additional straight covers, and ventilation head/corner parts.
| Item | Cost (Tax Included) |
|---|---|
| New Indoor/Outdoor Cover (up to 2m straight, 1 bend) | ¥8,800 |
| Reuse Existing Outdoor Cover (up to 2m straight, 1 bend) | ¥2,200 |
| Reuse Existing Indoor Cover (up to 2m straight, 1 bend) | ¥4,400 |
| Additional Straight Cover (per 1m) | ¥3,300 |
| Ventilation Head / Corner Part | ¥2,200 |
Piping covers are available in 5 colors (Ivory, Brown, Gray, Black, White).
Power Supply Related Work:

Figure 5: Additional Costs for Power Supply Related Work. This image lists costs for dedicated electrical wiring, outlet replacement, outlet extension, voltage switching, and molding work.
| Item | Cost (Tax Included) |
|---|---|
| Dedicated Electrical Wiring (up to 10m exposed, includes branch breaker/outlet) | ¥13,750 |
| Outlet Replacement (100V/200V) | ¥2,200 |
| Outlet Extension (up to 5m exposed wiring) | ¥3,300 |
| Voltage Switching (if voltage differs, assembly work in distribution board for 100V/200V) | ¥2,750 |
| Molding Work (per 1m of power cord molding finish) | ¥550 |
Operation
This section provides general guidance on operating your SHARP AY-S25V-W air conditioner. For detailed instructions on specific modes and advanced features, please refer to the remote control manual that came with your unit.
Basic Functions:
- Power On/Off: Press the power button on the remote control to turn the unit on or off.
- Mode Selection: Use the mode button to switch between Cooling, Heating, Dry, and Fan modes.
- Temperature Adjustment: Use the up/down arrows to set your desired temperature.
- Fan Speed: Adjust the fan speed to your preference (Auto, Low, Medium, High).
Cooling Mode:
Ideal for hot weather. Set the desired temperature, and the unit will cool the room to that setting. Recommended temperature range for cooling is typically 26-28°C (79-82°F).
Heating Mode:
Ideal for cold weather. Set the desired temperature, and the unit will heat the room. Recommended temperature range for heating is typically 20-24°C (68-75°F).
Maintenance
Regular maintenance ensures optimal performance and longevity of your air conditioner. Always disconnect power before performing any maintenance.
Air Filter Cleaning:
- Open the front panel of the indoor unit.
- Remove the air filters.
- Clean the filters using a vacuum cleaner or wash them with lukewarm water and mild detergent.
- Allow filters to dry completely before reinserting them.
- Close the front panel.
Frequency: Clean air filters every two weeks or more often if the unit is used frequently or in dusty environments.
Outdoor Unit Cleaning:
Periodically check the outdoor unit for any debris, leaves, or obstructions around the coils and fan. Gently remove any blockages. Do not spray water directly onto the electrical components.
Troubleshooting
Before contacting customer support, please check the following common issues:
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on | No power; remote control battery low | Check power plug/breaker; replace remote batteries |
| Insufficient cooling/heating | Dirty air filters; blocked outdoor unit; wrong mode selected; room too large | Clean filters; clear obstructions; select correct mode; ensure unit matches room size |
| Unusual noise | Loose parts; foreign object in fan; refrigerant flow sound (normal) | Contact professional if persistent or loud; normal sounds are acceptable |
| Water leakage | Clogged drain hose; improper installation | Check drain hose for kinks/blockages; contact installer for inspection |
If the problem persists after attempting these solutions, please contact qualified service personnel.
Specifications
Detailed technical specifications for the SHARP AY-S25V-W Air Conditioner:
| Feature | Detail |
|---|---|
| Applicable Room Size (目安) | Mainly 8 tatami mats |
| Heating Area | 6-8 tatami mats (10-13 m²) |
| Cooling Area | 7-10 tatami mats (11-17 m²) |
| Heating Capacity | 2.8 kW (0.8-4.4 kW) |
| Low Temperature Heating Capacity (at 2°C outdoor temp) | 3.2 kW |
| Cooling Capacity | 2.5 kW (0.8-3.2 kW) |
| Heating Power Consumption | 620 W (150-1330 W) |
| Cooling Power Consumption | 675 W (180-980 W) |
| Annual Energy Consumption | 815 kWh |
| Power Supply | Single-phase 100V-15A |
| Plug Type | Parallel type |
| Indoor Unit Dimensions (W×H×D) | 798 × 249 × 301 mm |
| Outdoor Unit Dimensions (W×H×D) | 670 (+57mm pipe cover) × 540 × 280 (incl. legs 326) mm |
| Indoor Unit Weight | 11 kg |
| Outdoor Unit Weight | 21 kg |
| Max. Piping Length | 15 m |
| Max. Piping Height Difference | 10 m |
Warranty and Support
Your SHARP AY-S25V-W Air Conditioner comes with a comprehensive warranty and support.
Installation Warranty:

Figure 6: 3-Year Installation Warranty. This image highlights a 3-year warranty specifically for installation work.
A 3-year installation warranty is included. If any operational defects occur due to installation issues within 3 years from the date of purchase, they will be covered under warranty. This warranty is provided by XPRICE, the installation cooperation company.
Note: This product is a genuine SHARP product, despite being listed as "No Brand Product" on some product pages due to specification display.
Customer Support:
For any inquiries regarding product operation, maintenance, or warranty claims, please contact the seller or the authorized service center. Refer to your purchase documentation for specific contact details.
Some remote islands and areas may not be serviceable. Please confirm service availability for your region.