1. Introduction
This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your AIVOLT 1400W Silent Inverter Generator. Please read this manual thoroughly before operating the generator and keep it for future reference.
The AIVOLT 1400W Inverter Generator is designed to provide stable power for various applications, including sensitive electronics, outdoor activities, and as a backup power source.
2. Key Features
- Inverter Technology: Provides stable, clean power suitable for sensitive electronics.
- Silent Operation: Engineered for reduced noise levels, enhancing user comfort.
- Multiple Output Options: Includes AC 230V, DC 12V, and USB Type-A ports for versatile connectivity.
- Lightweight and Portable: Compact design for easy transport and use in various locations.
- ECO-MODE: Optimizes fuel consumption by adjusting engine speed based on load.
- Parallel Ready: Allows connection of two units for increased power output (parallel kit sold separately).

Figure 2.1: The generator's lightweight design (12.8 kg) makes it easy to carry.

Figure 2.2: The generator's quiet operation allows for comfortable outdoor activities.
3. Safety Information
Your safety and the safety of others are very important. This manual contains important safety messages. Please read them carefully.
3.1 General Safety Precautions
- Always operate the generator outdoors in a well-ventilated area. Carbon monoxide is a colorless, odorless, poisonous gas.
- Keep children and pets away from the generator during operation.
- Do not operate the generator in rain or wet conditions.
- Ensure the generator is placed on a level surface.
- Turn off the generator and allow it to cool before refueling.
- Keep flammable materials away from the generator.
3.2 Fuel Safety
- Use only fresh, unleaded gasoline.
- Do not overfill the fuel tank.
- Wipe up any spilled fuel immediately.
- Store fuel in an approved container in a well-ventilated area, away from ignition sources.
3.3 Electrical Safety
- Do not connect the generator to a building's electrical system unless an approved transfer switch has been installed by a qualified electrician.
- Ensure all electrical connections are secure and in good condition.
- Do not overload the generator.
4. Component Identification
Familiarize yourself with the various parts of your AIVOLT Inverter Generator.

Figure 4.1: Overall view of the AIVOLT 1400W Inverter Generator, highlighting its compact design and control panel layout.

Figure 4.2: Detailed view of the control panel, showing the Hour Meter, 2x USB Type-A ports, ECO-MODE switch, 12V DC Outlet, Parallel Operation Outlets, and 230V AC Outlet.
Key Components:
- Fuel Tank Cap: For adding gasoline.
- Choke Lever: Used for starting the engine, especially during cold starts.
- Engine Switch: Controls engine operation (OFF/ON/START).
- Hour Meter: Displays total operating hours for maintenance tracking.
- AC 230V Outlet: For connecting standard AC appliances.
- DC 12V Outlet: For connecting 12V DC devices.
- USB Type-A Outlets (x2): For charging USB-powered devices like smartphones and tablets.
- ECO-MODE Switch: Engages fuel-saving mode by adjusting engine speed.
- Parallel Operation Outlets: For connecting two generators in parallel to increase power output (requires a separate parallel kit).
- Reset Button: Resets the circuit breaker in case of an overload.
5. Setup and Preparation
5.1 Unpacking
Carefully remove the generator from its packaging. Inspect for any damage during shipping. Ensure all included components (Tool Kit) are present.
5.2 Adding Engine Oil
The generator is shipped without engine oil. Before first use, you must add the recommended engine oil.
- Place the generator on a level surface.
- Locate the oil fill cap/dipstick.
- Remove the cap/dipstick and slowly add the recommended oil (refer to specifications for oil type and capacity) until it reaches the upper mark on the dipstick. Do not overfill.
- Securely replace the oil fill cap/dipstick.
5.3 Adding Fuel
Use fresh, unleaded gasoline with an octane rating of 87 or higher.
- Ensure the generator is turned OFF and has cooled down.
- Unscrew the fuel tank cap.
- Slowly pour gasoline into the fuel tank (capacity: 2.5L), being careful not to overfill. Leave a small air gap at the top.
- Securely replace the fuel tank cap.
Warning: Do not smoke or allow open flames near the generator when refueling.
6. Operating Instructions
6.1 Starting the Generator
- Ensure the generator is on a level surface and away from any obstructions.
- Make sure all electrical devices are disconnected from the generator outlets.
- Turn the fuel cap vent lever to the "ON" position (if applicable).
- Move the choke lever to the "CHOKE" position (for cold starts).
- Turn the engine switch to the "START" position.
- Once the engine starts, slowly move the choke lever to the "RUN" position.
- Allow the generator to warm up for a few minutes before connecting electrical loads.
6.2 Connecting Electrical Devices
Once the generator is running smoothly, you can connect your devices.
- AC 230V Outlets: Plug in your 230V AC appliances. Ensure the total wattage does not exceed the generator's rated output (1100W continuous, 1400W peak).
- DC 12V Outlet: Connect 12V DC devices.
- USB Type-A Outlets: Connect USB cables to charge smartphones, tablets, and other compatible devices.

Figure 6.1: The generator can power various devices for outdoor activities.
6.3 ECO-MODE Operation
The ECO-MODE switch allows the generator to automatically adjust engine speed to match the load, improving fuel efficiency and reducing noise.
- To activate ECO-MODE, switch the ECO-MODE lever to the "ON" position.
- The engine speed will decrease when the load is light, and increase when more power is required.
- For maximum power output or when starting high-load devices, it is recommended to turn ECO-MODE "OFF".

Figure 6.2: Visual representation of key features including ECO-MODE for fuel saving.
6.4 Parallel Operation
Two AIVOLT 1400W Inverter Generators can be connected in parallel to double the available power output. A parallel kit (sold separately) is required for this operation.
- Ensure both generators are turned OFF and cooled.
- Connect the parallel kit cables to the designated parallel operation outlets on both generators.
- Start both generators individually as described in Section 6.1.
- Once both generators are running stably, you can connect your high-power devices to the parallel kit's outlets.

Figure 6.3: Two AIVOLT generators connected for parallel operation, increasing total power output.
6.5 Stopping the Generator
- Disconnect all electrical devices from the generator outlets.
- Allow the generator to run for a few minutes without load to cool down.
- Turn the engine switch to the "OFF" position.
- Turn the fuel cap vent lever to the "OFF" position (if applicable).
7. Maintenance
Regular maintenance is crucial for the longevity and optimal performance of your generator. Always ensure the generator is turned OFF and cooled before performing any maintenance.
7.1 Maintenance Schedule
| Item | First 20 Hours / Monthly | Every 50 Hours / 3 Months | Every 100 Hours / 6 Months | Every 300 Hours / Annually |
|---|---|---|---|---|
| Check Engine Oil Level | ✓ | ✓ | ✓ | ✓ |
| Change Engine Oil | ✓ | ✓ | ||
| Clean Air Filter | ✓ | |||
| Check Spark Plug | ✓ | |||
| Clean Fuel Filter | ✓ |
7.2 Storage
If storing the generator for an extended period:
- Drain the fuel tank and carburetor.
- Change the engine oil.
- Remove the spark plug and pour a small amount of engine oil into the cylinder. Pull the recoil starter a few times to distribute the oil, then reinstall the spark plug.
- Store in a clean, dry, well-ventilated area.
8. Troubleshooting
This section provides solutions to common operational issues. For problems not listed here, please contact customer support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Engine will not start | No fuel Low oil level Choke not set correctly Engine switch OFF | Add fuel Add oil Adjust choke Turn engine switch to START |
| No power output | Overload Circuit breaker tripped ECO-MODE engaged with high load | Reduce load Press Reset button Turn ECO-MODE OFF |
| Engine runs rough | Stale fuel Dirty air filter Spark plug issue | Drain and replace with fresh fuel Clean/replace air filter Inspect/replace spark plug |
9. Specifications
| Feature | Detail |
|---|---|
| Brand | AIVOLT |
| Model | 1400W |
| Max Power | 1400 Watts |
| Rated Power | 1100 Watts |
| Output Wattage (Specific) | 1260 Watts |
| Fuel Type | Gasoline |
| Fuel Tank Capacity | 2.5 Liters |
| Run Time (50% load) | 5 hours 16 minutes |
| Run Time (75% load) | 4 hours |
| Run Time (100% load) | 3 hours 6 minutes |
| AC Voltage | 230 Volts |
| DC Output | 12 Volts |
| USB Output | Type-A (x2) |
| Noise Level (0% load) | 57dB |
| Noise Level (50% load) | 63dB |
| Noise Level (100% load) | 68dB |
| Item Weight | 12.8 Kilograms |
| Product Dimensions (L x W x H) | 43L x 25.2W x 40H Centimeters |
| Included Components | Tool Kit |

Figure 9.1: Generator dimensions for reference.
10. Warranty and Support
For warranty information or technical support, please refer to the documentation included with your purchase or contact AIVOLT customer service. Keep your proof of purchase for warranty claims.
Contact Information: Please refer to the manufacturer's official website or your purchase receipt for the most up-to-date contact details.