1. Introduction
The Kiprim DC605Pro is a versatile 2-in-1 device combining a programmable DC power supply and a digital multimeter. It offers a maximum output of 60V and 5A, with advanced features such as data storage, Over Current Protection (OCP), Over Voltage Protection (OVP), PC software control, and a USB charging port. This manual provides essential information for safe and efficient operation of your device.
2. Safety Instructions
- Always connect the power cord to a grounded outlet to prevent electric shock.
- Do not operate the device in wet or damp conditions.
- Do not open the device casing. Refer servicing to qualified personnel only.
- Ensure proper ventilation around the device to prevent overheating.
- Verify voltage and current settings before connecting to a circuit to avoid damage to the device or the circuit under test.
- Use only the provided accessories or approved replacements.
3. Product Overview
Front Panel

Figure 3.1: Front and Rear Panel Layout
This diagram illustrates the key components and controls on the front and rear panels of the DC605Pro. The front panel includes the 2.8-inch TFT LCD screen, function buttons (F1-F4), adjustment knob, output terminals, and a USB charging port. The rear panel features the AC power input, device USB port, fuse box, and cooling fan.
- 2.8-inch TFT LCD Screen: Displays voltage, current, power, waveform, and multimeter readings.
- Function Buttons (F1-F4): Used for menu navigation, setting adjustments, and quick access to features.
- Adjustment Knob: Rotates to change values and presses to confirm selections.
- Output Terminals: Red (+) and Black (-) for power supply output.
- Multimeter Input Terminals: For connecting multimeter probes.
- USB Charging Port (5V/1A): For charging external devices.
Rear Panel
- AC Power Input: Connects to the main power supply.
- Power Switch: Turns the device on/off.
- Device USB Port: For PC software connection and firmware updates.
- Cooling Fan: Ensures proper heat dissipation.
4. Setup
- Unpacking: Carefully remove the DC605Pro and all accessories from the packaging. Verify that all components listed in the packing list are present.
- Placement: Place the device on a stable, level surface with adequate ventilation. Ensure no objects obstruct the cooling fan on the rear panel.
- Power Connection: Connect the provided AC power cord to the AC power input on the rear panel of the DC605Pro and then to a grounded electrical outlet.
- Initial Power On: Flip the power switch on the rear panel to the 'ON' position. The LCD screen should illuminate.
- Self-Test: The device will perform a self-test upon startup. Wait for the main interface to appear before proceeding.
5. Operating Instructions
5.1. Basic Power Supply Operation
- Setting Voltage and Current:
a. On the main display, use the adjustment knob to select the voltage or current parameter you wish to modify.
b. Rotate the knob to adjust the value. Press the knob to confirm the selection or move to the next digit.
c. The 'Set' values indicate the desired output, while 'Limit' values represent the Over Voltage Protection (OVP) and Over Current Protection (OCP) thresholds. - Output Control: Press the 'On/Off' button on the front panel to enable or disable the power output. The display will indicate 'ON' or 'OFF' accordingly.
5.2. Programmable Features
Memory Functions (M1-M4)

Figure 5.1: Memory Presets Display
The device allows storing up to four custom settings (M1-M4) for quick recall. Use the 'Memory' button to access and manage these presets.
Waveform Editing

Figure 5.2: Waveform Display
The DC605Pro supports editing and retaining output waveforms with up to 10 editable points. Each point allows setting output voltage, current, waveform duration, and selection status. Access this feature via the 'List' button and follow the on-screen prompts to define your custom waveform.
5.3. Multimeter Functions

Figure 5.3: Multimeter Measurement in Progress
The device can measure resistance, AC/DC voltage, AC/DC current, continuity, and capacitance. Connect the multimeter probes to the dedicated input terminals. Use the 'Mode' button to switch to multimeter mode and select the desired measurement function.
5.4. Multiple Display Modes

Figure 5.4: Multiple Display Modes
The DC605Pro offers four display modes: numerical display of the power supply, numerical waveform display, multimeter display, and simultaneous display of power supply and multimeter. Use the 'DISP' button to cycle through these modes.
5.5. Protection Features (OVP, OCP)

Figure 5.5: OVP/OCP Buttons
The device is equipped with Over Voltage Protection (OVP) and Over Current Protection (OCP) to safeguard your equipment. These limits can be set via the menu. When the output voltage or current exceeds the preset limits, the device will automatically cut off the output to prevent damage.
5.6. USB Charging Port

Figure 5.6: USB Charging Port in Use
A convenient 5V/1A USB charging port is located on the front panel, allowing you to charge mobile phones or tablets directly from the power supply.
5.7. PC Software Connection

Figure 5.7: PC Software Interface
The DC605Pro can be connected to a computer via the rear USB port. Dedicated PC software allows for remote control, data logging, and advanced programming of the power supply functions. Refer to the software manual for detailed instructions on installation and usage.
6. Maintenance
- Cleaning: Disconnect the power supply before cleaning. Use a soft, dry cloth to wipe the exterior of the device. Do not use abrasive cleaners or solvents.
- Ventilation: Regularly check that the cooling fan and ventilation slots are free from dust and debris. Clean as necessary using compressed air.
- Storage: When not in use for extended periods, store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- Fuse Replacement: If the device fails to power on, check the fuse located on the rear panel. Replace it with a fuse of the same type and rating (e.g., 250V 5A).
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on | Power cord not connected; Power switch off; Blown fuse | Check power cord connection; Turn power switch on; Replace fuse. |
| No output voltage/current | Output is off; OVP/OCP triggered; Incorrect settings | Press 'On/Off' button to enable output; Check and reset OVP/OCP limits; Verify voltage/current settings. |
| Multimeter readings are inaccurate | Incorrect measurement mode; Loose probe connections; Damaged probes | Select correct measurement mode; Ensure probes are securely connected; Replace damaged probes. |
| Device overheats | Blocked ventilation; Excessive load | Clear ventilation slots; Reduce output load; Ensure ambient temperature is within operating limits. |
| PC software connection issues | Incorrect USB cable; Driver not installed; Software error | Use correct USB A-B cable; Install necessary drivers from the provided CD or website; Reinstall PC software. |
8. Specifications
| Parameter | Value |
|---|---|
| Model Number | DC605Pro |
| Output Voltage | 0-60 V |
| Output Current | 0-5 A |
| Maximum Power | 300 W |
| Display | 2.8-inch TFT LCD |
| Multimeter Functions | Resistance, AC/DC Voltage, AC/DC Current, Continuity, Capacitance |
| Protection Features | OVP (Over Voltage Protection), OCP (Over Current Protection) |
| USB Charging Output | 5V/1A |
| Product Dimensions (L x W x H) | 22.6 x 8.2 x 14.2 cm |
| Item Weight | 1.5 kg |
| Certifications | CE, RoHS |
9. Warranty and Support
Kiprim products are designed and manufactured to the highest quality standards. For warranty information, technical support, or service inquiries, please refer to the contact details provided with your purchase documentation or visit the official Kiprim website. Please retain your proof of purchase for warranty claims.