1. Safety Information
Read and understand all safety warnings and instructions before installing or operating this product. Failure to follow these instructions may result in electric shock, fire, serious injury, or death. Keep this manual for future reference.
Electrical Precautions:
- Do not walk on wet areas of the basement until all power has been turned off. If the main power supply is in a wet basement, call an electrician.
- Never handle the control unit with wet hands or while standing on a wet surface.
- Always unplug the control unit and disconnect the cables from the battery before attempting any maintenance or cleaning.
- Always unplug the main pump when installing or servicing the backup pump or float switch to avoid electric shock.
- Do not expose the control unit to rain or snow.
- Do not pull the cord when disconnecting the control unit. Pull the plug.
Battery Precautions:
- Explosive gases could cause serious injury or death. Cigarettes, flames, or sparks could cause the battery to explode in enclosed spaces. Charge in a well-ventilated area. Always shield eyes and face from battery. Keep vent caps tight and level.
- Never smoke or allow a spark or flame in the vicinity of the battery.
- Use the VEVOR sump pump battery backup system only with a 12V deep cycle battery. Do not use the control unit for charging dry-cell batteries that are most commonly used with home appliances.
- Be sure the area around the battery is well-ventilated.
- When cleaning or adding water to the battery, first fan the top of the battery with a piece of cardboard (or another non-metallic material) to blow away any hydrogen or oxygen gas that may have been emitted from the battery.
- Do not drop a metal tool onto the battery. It might spark or short-circuit the battery and cause an explosion.
- Remove personal metal items such as rings, bracelets, watches, etc. when working with a lead-acid battery. A short circuit through one of these items can melt it, causing a severe burn.
- Always remove the charger from the electrical outlet before connecting or disconnecting the battery cables. Check the polarity of the battery cables. The positive (+) battery post usually has a larger diameter than the negative (-) post.
2. Product Overview
The VEVOR 2000W Sump Pump Battery Backup System is designed to provide continuous power to your sump pump during power outages, ensuring your basement remains dry. This inverter automatically switches to battery power when the main power supply is interrupted.
Key Features:
- Unmatched Power: Features a robust 2000W output and 18.2A operating current, with dual outlets capable of supporting two sump pumps simultaneously.
- Real-Time Display: A high-definition LCD screen and LED indicator lights provide instant monitoring of vital information such as voltage, power, and battery level.
- Quick Plug Feature: Convenient 3-Pin plug design ensures quick and secure installation, reducing wiring hassles and security risks.
- Multi-Layered Protection: Includes overload, short circuit, overcharge, overvoltage, overheat protection, and a circuit breaker for enhanced safety.
- Lightning Fast Charging: Equipped with a 20A charging current, capable of charging a 100AH battery in approximately 5 hours, which is four times faster than a 5A charger.

Figure 1: VEVOR 2000W Sump Pump Battery Backup System connected to a sump pump and battery, illustrating its function during a power outage.

Figure 2: The high-definition LCD display provides real-time information on input/output voltage, load power, battery level, and frequency.
Video 1: An overview of a Sump Pump Battery Backup Power System, demonstrating its components and basic operation.
3. Package Contents
Verify that all items are present in the package before proceeding with installation.
- 1 x VEVOR 2000W Sump Pump Battery Backup System (Inverter)
- 1 x Power Cord
- 2 x Battery Connecting Cables (Red and Black)
- 6 x 40A Fuses
- User Manual

Figure 3: The image displays the VEVOR 2000W inverter along with its included accessories: power cord, battery connecting cables, and spare 40A fuses.
4. Setup
Proper installation is crucial for the safe and effective operation of your VEVOR Sump Pump Battery Backup System. This system requires a separate 12V deep cycle battery (not included).
Installation Steps:
- Prepare the Battery: Ensure your 12V deep cycle battery (recommended 100AH capacity) is fully charged and placed in a well-ventilated area.
- Connect Battery Cables: Connect the red battery cable to the positive (+) terminal of the battery and the red terminal of the inverter. Connect the black battery cable to the negative (-) terminal of the battery and the black terminal of the inverter. Ensure connections are tight and secure.
- Connect Sump Pump: Plug your sump pump(s) into the AC output outlets on the VEVOR inverter. The inverter features a 3-Pin plug design for secure connections.
- Connect AC Input: Plug the inverter's power cord into a standard 120V AC wall outlet. This will provide power to the inverter and charge the connected battery.
- Power On: Turn on the inverter using the power switch. The LCD display will illuminate, showing input/output voltage and other system parameters.

Figure 4: Detailed view of the VEVOR inverter's connections, including AC output, breaker, AC input, USB ports, and power switch.
Video 2: A general guide on how to install a battery backup sump pump system. This video provides visual steps for setting up a typical sump pump backup, which can be helpful for understanding the overall process.
5. Operating Instructions
Once installed, the VEVOR Sump Pump Battery Backup System operates largely automatically, providing seamless power during outages.
Normal Operation:
- When connected to AC power, the inverter charges the connected 12V deep cycle battery and passes AC power to the sump pump(s).
- The LCD display will show the input voltage (from AC mains), output voltage (to sump pump), load power, and battery charging status.
Power Outage Operation:
- In the event of a power outage, the inverter will automatically switch to battery power within milliseconds, ensuring uninterrupted operation of your sump pump(s).
- The LCD display will indicate the battery voltage as the input and the AC output voltage being supplied to the pump(s).
- The system will continue to power the sump pump(s) until the battery charge is depleted or AC power is restored.
Using USB/USB-C Ports:
- The inverter includes USB and USB-C ports for charging small electronic devices. These ports are active when the inverter is powered on, regardless of AC input status.

Figure 5: The 3-Pin plug design on the VEVOR inverter ensures a secure and straightforward connection for your sump pump, minimizing installation complexities.
6. Maintenance
Regular maintenance ensures the longevity and reliable performance of your VEVOR Sump Pump Battery Backup System.
General Maintenance:
- Cleaning: Periodically clean the exterior of the inverter with a dry, soft cloth. Ensure ventilation openings are free from dust and debris to prevent overheating.
- Connections: Regularly check all electrical connections (battery terminals, AC plugs, sump pump plugs) to ensure they are tight and free from corrosion.
- Battery Inspection: If using a lead-acid battery, check the electrolyte levels periodically and add distilled water if necessary (refer to battery manufacturer's instructions). Keep battery terminals clean.
Fuse Replacement:
- The system includes 40A fuses for protection. If a fuse blows, replace it with an identical 40A fuse. Always disconnect power from the inverter and battery before replacing fuses.
7. Troubleshooting
If you encounter issues with your VEVOR Sump Pump Battery Backup System, refer to the following common troubleshooting steps:
Common Issues and Solutions:
- No Power Output:
- Check if the inverter is turned on.
- Verify battery connections are secure and correctly polarized.
- Ensure the battery is charged.
- Check the AC input power cord connection.
- Inspect fuses for any blown fuses and replace if necessary.
- Alarm Sounds/Error on LCD:
- The LCD display provides real-time status and error indicators. Refer to the display for specific warnings (e.g., low voltage, overload, overheat).
- Overload Protection: If an overload is detected, the inverter will shut down. Disconnect some load, then restart the inverter. Ensure total load does not exceed 2000W.
- Low Voltage Protection: If the battery voltage drops too low, the inverter will shut down to protect the battery. Recharge the battery.
- Overheat Protection: If the internal temperature is too high, the inverter will shut down. Ensure proper ventilation and clear any obstructions from the cooling fans.
- Short Circuit Protection: The inverter will shut down if a short circuit is detected. Identify and resolve the short circuit before restarting.
- Battery Not Charging:
- Ensure the AC input power cord is securely plugged into a live outlet.
- Check the power cord and internal fuses.
- Verify battery connections are correct.

Figure 6: The VEVOR inverter is equipped with multiple protection mechanisms including overload, short circuit, overcharge, overvoltage, and overheat protection to ensure safe operation.
8. Specifications
| Feature | Specification |
|---|---|
| Manufacturer | VEVOR |
| Model Number | SGPC2000W-121 |
| Rated Power | 2000W |
| Operating Current | 18.2A |
| Input Voltage | 12 Volts (DC) |
| Output Voltage | 120V AC / 60Hz |
| Total Power Outlets | 2 |
| Charging Current | 20A |
| Recommended Battery Capacity | 100AH (12V Deep Cycle) |
| Display Style | LCD |
| Item Weight | 5.57 kg (12.28 lbs) |
| Product Dimensions (L x W x H) | 49.81 x 22 x 16.21 cm (19.61 x 8.66 x 6.38 inches) |
| Included Components | Power Cord, Battery Connecting Cables, 40A Fuses |

Figure 7: Visual representation of the VEVOR 2000W inverter's dimensions and key technical specifications.
9. Warranty and Support
VEVOR is committed to providing reliable products and customer satisfaction. For warranty information, technical support, or any inquiries regarding your VEVOR 2000W Sump Pump Battery Backup System, please refer to the contact information provided in your product packaging or visit the official VEVOR website.