1. Introduction
This manual provides essential information for the safe and efficient operation of your Argo Kary 8000 BTU Portable Air Conditioner. This unit is designed for domestic use, offering three primary functions: cooling, ventilation, and dehumidification. It provides a practical solution for maintaining a comfortable indoor environment without requiring permanent installation of external units. Please read this manual thoroughly before using the appliance and retain it for future reference.
2. Important Safety Information
To reduce the risk of fire, electric shock, or injury, always follow basic safety precautions when operating this appliance.
- Read all instructions carefully before use.
- Keep the appliance out of reach of children and pets.
- Ensure proper ventilation around the unit. Do not block air inlets or outlets.
- Use only with the specified voltage (230 Volt).
- Do not operate the unit if the power cord or plug is damaged.
- Do not insert objects into the air outlets.
- This appliance contains R290 refrigerant. Servicing should only be performed by qualified personnel. Do not attempt to dismantle or repair the refrigerant circuit yourself.
- Always unplug the unit before cleaning or performing maintenance.
3. Product Overview
3.1 Components
The Argo Kary portable air conditioner includes the main unit, a flexible exhaust hose, a window adapter, and a kit for fixed window installation. A multifunction remote control is also provided for convenient operation.

Figure 1: Front view of the Argo Kary portable air conditioner, showcasing its compact design and air outlet grille.

Figure 2: Angled view of the Argo Kary unit, highlighting its side panels and overall aesthetic.
4. Setup and Installation
4.1 Unpacking
Carefully remove all packaging materials from the unit. Inspect the appliance for any signs of damage during transit. If damage is found, do not operate the unit and contact customer support.
4.2 Placement
Place the air conditioner on a flat, stable surface. Ensure there is adequate space around the unit (at least 30 cm) for proper air circulation. The unit's multidirectional wheels and side handles allow for easy movement and positioning in various rooms.

Figure 3: Diagram illustrating the dimensions of the Argo Kary portable air conditioner (685mm H x 330mm W x 280mm D).
4.3 Exhaust Hose Installation
The flexible exhaust hose (155 mm diameter, 1.5 m extended length) is crucial for expelling hot air outdoors. Attach one end of the hose to the air outlet on the back of the unit. Connect the other end to either the provided window adapter for temporary use or the fixed window kit for a more permanent setup. Ensure the hose is as straight and short as possible to maximize efficiency.
4.4 Power Connection
Plug the power cord into a grounded 230 Volt, 50 Hz electrical outlet. Ensure the outlet is suitable for the unit's power requirements (0.75 kW).
5. Operating Instructions
5.1 Control Panel and Remote Control
The unit can be operated using the digital control panel located on top of the appliance or via the multifunction remote control. The LED display shows current settings and temperature.

Figure 4: Close-up view of the digital control panel on the Argo Kary unit, showing various function buttons and the LED display.
5.2 Operating Modes
- Cooling Mode: Press the 'MODE' button until the cooling indicator lights up. Use the temperature buttons to set your desired room temperature. The unit will cool the room to 8000 BTU/h.
- Ventilation Mode: Press the 'MODE' button until the fan indicator lights up. In this mode, the unit circulates air without cooling. You can adjust the fan speed.
- Dehumidification Mode: Press the 'MODE' button until the dehumidification indicator lights up. The unit will remove moisture from the air, with a capacity of up to 19.2 liters per 24 hours.
5.3 Temperature Adjustment
In cooling mode, use the 'TEMP+' and 'TEMP-' buttons on the control panel or remote to increase or decrease the target temperature.
5.4 Fan Speed
Press the 'SPEED' button to cycle through the available fan speeds (High/Low). The unit has an airflow capacity of 270-250 m³/h.
5.5 Timer Function
The 'TIMER' button allows you to program the unit to turn ON or OFF automatically within a 24-hour period. Follow the instructions in the full manual for detailed timer setup.
5.6 Sleep Function
Activate the 'SLEEP' function for quieter operation, ideal for nighttime use. This mode adjusts settings to maintain comfort while minimizing noise.
5.7 Memory Function
The 'MEMORY' function ensures that if a power outage occurs, the unit will automatically restart with the last used settings once power is restored.
5.8 Airflow Direction
The vertical louvers oscillate automatically to distribute air evenly. The horizontal louvers can be adjusted manually to direct the airflow as desired.
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your air conditioner.
6.1 Air Filter Cleaning
The air filter is removable and washable. It should be cleaned periodically (e.g., every two weeks, depending on usage) to prevent dust buildup and maintain efficient airflow. Refer to the full manual for instructions on how to remove and clean the filter.
6.2 Condensate Management
In cooling mode, the unit features automatic vaporization of condensate, reducing the need for manual draining. In dehumidification mode, it is possible to connect a continuous drain hose for uninterrupted operation.
7. Troubleshooting
If you encounter issues with your Argo Kary air conditioner, refer to the following common solutions:
- Unit does not turn on: Check if the power cord is securely plugged into a working electrical outlet. Ensure the power button is pressed.
- Insufficient cooling: Verify that all windows and doors are closed. Ensure the exhaust hose is properly installed and expelling hot air outdoors. Clean the air filter if it is dirty.
- Reduced airflow: Clean the air filter. Ensure there are no obstructions to the air inlets or outlets.
- Unusual noise: Check if the unit is placed on a flat, stable surface. Ensure no foreign objects are inside the unit.
For persistent problems or issues not covered here, please contact Argo customer support.
8. Technical Specifications

Figure 5: Italian Product Data Sheet for Argo Kary, detailing technical specifications.
| Feature | Specification |
|---|---|
| Model Name | Argoclima Kary |
| Model Number | 398400022 |
| Cooling Capacity (Max) | 8000 BTU/h (2.00 kW) |
| Energy Efficiency Class | A |
| EER (Rated) | 2.60 |
| Dehumidification Capacity | 19.2 l/24h |
| Airflow (Max) | 270-250 m³/h |
| Fan Speeds | 2 |
| Sound Pressure Level | 54-60 dB(A) |
| Power Supply | 220-240V~/1/50Hz |
| Rated Power Input | 0.75 kW |
| Hourly Electricity Consumption | 0.8 kWh/60 min |
| Refrigerant Type | R290 |
| GWP (Global Warming Potential) | 3 |
| Exhaust Hose Diameter | 155 mm |
| Exhaust Hose Length (Extended) | 1.5 m |
| Net Weight | 20 kg |
| Dimensions (H x W x D) | 685 x 330 x 280 mm |
| Recommended Room Size | Up to 20 square meters |
For more detailed product information, refer to the EPREL database: EPREL Product Information
9. Warranty and Support
This Argo Kary portable air conditioner comes with a limited warranty. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact Argo customer support.
Customer Support Contact Information:
- Website: www.argoclima.com
- Email: argo.marketing@argoclima.com
- Phone: +39 0331 755111
When contacting support, please have your model number (Kary 398400022) and purchase details ready.