1. Introduction
This manual provides comprehensive instructions for the SCS Sentinel AAM0130 SimplyControl 2 Channel Gate Remote Control. Designed and manufactured in France, this remote control offers a convenient and effective solution for operating compatible gate systems. Its casing is made from 100% recycled plastic, reflecting a commitment to sustainability.
The AAM0130 remote control operates on a transmission frequency of 433.92MHz and is powered by a single CR2032 lithium battery. It is designed for ease of use and reliability.
Key Features:
- Effective and Convenient Control: Provides remote operation for compatible gate systems with a range of up to 40 meters in open field conditions.
- Compatibility: Compatible with SimplyOpen, OpenGate, Prim' by SCS Sentinel, SG 1/2/3, CarGate 800 TRIO, and CarOne 600 gate operators.
- Compact Design: Easy to carry and operate.
- Sustainable Materials: Case made from 100% recycled plastic, packaged in recyclable cardboard from sustainably managed forests.

Figure 1: Product packaging for the SCS Sentinel AAM0130 remote control, highlighting its sustainable design and key features.
2. Setup
2.1. Battery Installation
The SCS Sentinel AAM0130 remote control requires one CR2032 lithium battery (included). Follow these steps to install or replace the battery:
- Locate the battery compartment on the back of the remote control.
- Using a small screwdriver or coin, gently pry open the battery cover.
- Insert the CR2032 battery with the positive (+) side facing upwards.
- Replace the battery cover, ensuring it clicks securely into place.
Note: Ensure correct battery polarity to prevent damage to the device.
2.2. Pairing with Your Gate Operator
The AAM0130 remote control must be paired with your specific gate operator system before use. The pairing procedure varies depending on the model of your gate operator (e.g., SimplyOpen, OpenGate, Prim' by SCS Sentinel, SG 1/2/3, CarGate 800 TRIO, CarOne 600). Please refer to the instruction manual provided with your gate operator for detailed pairing steps.
Typically, the pairing process involves:
- Accessing the programming mode on your gate operator's control unit.
- Pressing a specific button on the remote control to transmit a signal.
- Confirming the successful pairing on the gate operator unit.
If you encounter difficulties, consult the gate operator's manual or contact SCS Sentinel technical support.

Figure 2: The SCS Sentinel AAM0130 remote control, showing its two distinct yellow control buttons.
3. Operating Instructions
The SCS Sentinel AAM0130 is a 2-channel remote control, meaning it can control two distinct functions or two separate gate operators, depending on how it is programmed with your system.
3.1. Basic Operation
- Button 1 (Top Yellow Button): Typically programmed for the primary function, such as opening and closing your main gate. A single press will activate the programmed action (e.g., open, close, stop).
- Button 2 (Bottom Yellow Button): Can be programmed for a secondary function, such as partial opening for pedestrian access, controlling a second gate, or activating an auxiliary device.
To operate, simply press the desired button firmly. The remote control has an effective range of up to 40 meters in open field conditions. Obstacles such as walls, vehicles, or dense foliage may reduce this range.

Figure 3: Demonstrating the use of the remote control to operate a garage door.

Figure 4: An illustration showing the comfortable grip of the remote control in hand.
4. Maintenance
4.1. Battery Replacement
When the remote control's range decreases significantly or it stops responding, it is likely time to replace the CR2032 lithium battery. Refer to Section 2.1 for detailed battery installation instructions.
Important: Dispose of used batteries responsibly according to local regulations.
4.2. Cleaning
To clean the remote control, use a soft, dry cloth. Do not use abrasive cleaners, solvents, or immerse the device in water. Keep the remote control away from excessive moisture and direct sunlight.
5. Troubleshooting
If you experience issues with your SCS Sentinel AAM0130 remote control, consult the following table for common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Remote control does not work. | Dead or incorrectly installed battery. Remote not paired with gate operator. Out of range. | Replace battery (CR2032) and ensure correct polarity. Re-pair the remote control with your gate operator (refer to gate operator manual). Move closer to the gate operator. |
| Reduced operating range. | Low battery. Obstructions between remote and receiver. Radio interference. | Replace battery. Ensure clear line of sight. Identify and remove sources of interference (e.g., other wireless devices). |
| Gate opens/closes intermittently. | Weak battery. Signal interference. Loose connection in gate operator. | Replace battery. Try operating from a different location. Consult your gate operator's manual or a qualified technician. |
If the problem persists after trying these solutions, please contact SCS Sentinel technical support.
6. Specifications
| Feature | Detail |
|---|---|
| Model Name | SimplyControl |
| Model Number | AAM0130 |
| Brand | SCS Sentinel |
| Number of Channels | 2 |
| Transmission Frequency | 433.92MHz |
| Maximum Range | 40 meters (open field) |
| Battery Type | 1 x CR2032 Lithium Battery |
| Connectivity Technology | Wireless |
| Product Dimensions | 1 x 1 x 1 cm (approximate) |
| Item Weight | 0.1 Grams |
| Material | 100% recycled plastic casing |
| Color | Yellow (buttons), Black (casing) |
7. Warranty and Support
7.1. Warranty Information
The SCS Sentinel AAM0130 remote control is backed by a two-year warranty. This warranty covers manufacturing defects and ensures the reliability of the product. Please retain your proof of purchase for warranty claims.
7.2. Technical Support
SCS Sentinel offers dedicated technical support to assist you with product installation, operation, and troubleshooting. Our technical support team is based in France and is available to provide sound and personal advice.
For assistance, please visit the official SCS Sentinel website or refer to the contact information provided with your product packaging. Your satisfaction is our priority.
Documents and downloads
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.