KHIRY AKO-D14123-F0003

AKO-D14123-F0003 Electronic Thermostat Temperature Contactor

User Manual

1. Introduction

This user manual provides detailed instructions for the installation, operation, and maintenance of the KHIRY AKO-D14123-F0003 Electronic Thermostat Temperature Contactor. Please read this manual thoroughly before using the device to ensure safe and efficient operation.

2. Safety Information

WARNING: Risk of Electric Shock!

  • Installation and maintenance should only be performed by qualified personnel.
  • Disconnect power before performing any wiring or maintenance.
  • Ensure proper grounding to prevent electric shock.
  • Do not operate the device if it is damaged or wet.
  • Adhere to all local and national electrical codes.

This device is designed for industrial and scientific applications. Use it only for its intended purpose as described in this manual.

3. Package Contents

Verify that all items are present in the package:

  • AKO-D14123-F0003 Electronic Thermostat Temperature Contactor
  • User Manual (this document)

If any items are missing or damaged, contact your supplier immediately.

4. Product Overview

The AKO-D14123-F0003 is an electronic thermostat temperature contactor designed for precise temperature control in various industrial applications. It features a digital display for temperature readings and control buttons for easy configuration.

4.1 Front Panel and Display

Front view of AKO-D14123-F0003 Electronic Thermostat showing digital display and control buttons.

Figure 1: Front view of the AKO-D14123-F0003 Electronic Thermostat. This image displays the digital temperature readout, the 'SET' button for configuration, and the power button. The compact design is evident, suitable for panel mounting.

  • Digital Display: Shows current temperature and programming parameters.
  • SET Button: Used to enter programming mode and confirm settings.
  • Up/Down Buttons: Used to navigate menus and adjust values.
  • Power Button: Turns the device on/off.

4.2 Rear Panel and Wiring Terminals

Rear view of AKO-D14123-F0003 Electronic Thermostat showing wiring terminals and product labels.

Figure 2: Rear view of the AKO-D14123-F0003 Electronic Thermostat, highlighting the wiring terminals and product specification labels. The labels indicate the model number (REF. AKO-D14123-F0003), IP65 rating, temperature range (-10T50), and electrical specifications (230V~, 50/60Hz, 3.5VA). The terminal block is clearly visible for electrical connections.

  • Power Input Terminals: For connecting the main power supply (e.g., 230V~).
  • Sensor Input Terminals: For connecting the temperature sensor.
  • Output Relay Terminals: For connecting the controlled device (e.g., heater, cooler).

5. Setup and Installation

IMPORTANT: Ensure power is disconnected before proceeding with installation.

5.1 Mounting

The AKO-D14123-F0003 is designed for panel mounting. Cut an appropriate opening in the control panel according to the device dimensions. Secure the thermostat using the provided mounting clips or screws.

  • Ensure adequate ventilation around the device.
  • Avoid mounting near heat sources or in direct sunlight.

5.2 Wiring

Refer to the wiring diagram on the device label and the following general guidelines. Professional electrical installation is highly recommended.

  1. Connect the main power supply (e.g., 230V~, 50/60Hz) to the designated power input terminals (L and N).
  2. Connect the temperature sensor to the sensor input terminals. Ensure correct polarity if applicable.
  3. Connect the load (e.g., heater, cooler) to the output relay terminals (NO, NC, COM) as required by your application.
  4. Ensure all connections are secure and properly insulated.

Verify all wiring connections before restoring power.

6. Operating Instructions

6.1 Powering On/Off

Press the Power Button to turn the device on or off. When powered on, the display will show the current measured temperature.

6.2 Setting the Temperature Setpoint

  1. Press the SET Button once. The display will show the current setpoint value.
  2. Use the Up/Down Buttons to adjust the setpoint to your desired temperature.
  3. Press the SET Button again to confirm the new setpoint and exit the setting mode.

6.3 Advanced Settings (Programming Mode)

To access advanced parameters (e.g., hysteresis, calibration, operating mode), press and hold the SET Button for several seconds until the first parameter code appears. Use the Up/Down Buttons to navigate through parameters and the SET Button to select and modify them. Refer to the specific parameter list (not provided in this general manual) for detailed descriptions of each setting.

Caution: Incorrect advanced settings can lead to improper operation or damage. Only adjust if you understand the function of each parameter.

7. Maintenance

Always disconnect power before performing any maintenance.

  • Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Inspection: Periodically check wiring connections for tightness and signs of wear or damage.
  • Sensor Check: Ensure the temperature sensor is clean and properly positioned for accurate readings.

8. Troubleshooting

ProblemPossible CauseSolution
Device does not power on.No power supply; Loose wiring; Blown fuse.Check power source; Verify wiring connections; Check and replace fuse if necessary.
Incorrect temperature reading.Faulty sensor; Sensor not properly placed; Calibration error.Check sensor connection; Reposition sensor; Refer to advanced settings for calibration.
Load not switching.Incorrect setpoint; Wiring error to load; Faulty relay.Verify setpoint and hysteresis; Check load wiring; Contact support if relay is suspected faulty.
Display shows error code.Sensor fault; Internal error.Consult the specific error code list (if available in product documentation) or contact technical support.

If the problem persists after attempting these solutions, contact technical support.

9. Specifications

FeatureSpecification
BrandKHIRY
Model NameAKO-D14123-F0003 (as per product title) / KHIRY (as per specifications)
Control TypeButton Control
Item Weight50 Grams (1.76 ounces)
Package Dimensions1.18 x 0.79 x 0.39 inches
ASINB0D2VLRRGG
ManufacturerKHIRY
IP RatingIP65 (from image label)
Operating Temperature Range-10T50 (from image label, likely -10 to 50 degrees Celsius)
Voltage / Frequency230V~, 50/60Hz (from image label)
Power Consumption3.5VA (from image label)

10. Warranty and Support

For warranty information and technical support, please contact the manufacturer, KHIRY, or your authorized distributor. Keep your purchase receipt as proof of purchase.

For the most up-to-date information and support resources, please visit the official KHIRY website (if available).

Related Documents - AKO-D14123-F0003

Preview AKO DARWIN Temperature Controllers Datasheet and Selection Guide
Comprehensive technical datasheet for AKO DARWIN temperature controllers, detailing models, specifications, features, and wiring diagrams for selection and installation.
Preview AKO DARWIN Temperature Controllers: Data Sheet & Selection Guide
Detailed data sheet for AKO DARWIN temperature controllers. Features quick selection guides, technical specifications, and model variations for refrigeration and HVAC applications.
Preview AKO D14xxx / D101xx Series Temperature Controllers - Technical Manual & Specifications
Detailed technical manual and specifications for AKO D14xxx, D101xx, D141xx, and D140xx series temperature controllers. Includes warnings, operation, wiring diagrams, start-up wizard, accessories, and technical data.
Preview AKO Darwin Thermometers and Temperature Controllers User Manual
Comprehensive user manual for AKO Darwin series thermometers and temperature controllers, covering features, installation, configuration, operation, and technical specifications. Includes model details, wiring diagrams, and parameter settings.
Preview Fiche Technique Contrôleurs de Température AKO DARWIN
Guide de sélection et spécifications techniques pour la gamme de contrôleurs de température AKO DARWIN, incluant les caractéristiques, entrées, sorties, et schémas de connexion.
Preview AKO Thermometers and Temperature Controllers User Manual
Comprehensive user manual for AKO Darwin range thermometers and temperature controllers. Covers setup, operation, wiring, and technical specifications for refrigerating equipment control.