1. Introduction
Thank you for choosing the GGM Gastro KTJ187ND6 Refrigerated Table. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your new appliance. Please read this manual thoroughly before using the unit and keep it for future reference.

Figure 1.1: GGM Gastro KTJ187ND6 Refrigerated Table. This image shows the stainless steel refrigerated table with six drawers, one of which is partially open, revealing the interior storage space. The refrigeration unit is visible on the right side.
2. Safety Information
To ensure safe operation and prevent damage to the appliance or injury to users, please observe the following safety precautions:
- Electrical Safety: Ensure the power supply matches the specifications (230V/50Hz). Do not use extension cords or adapters. Always unplug the unit before cleaning or maintenance.
- Placement: Position the unit on a stable, level surface. Ensure adequate ventilation around the refrigeration unit to prevent overheating. Maintain a minimum clearance of 10 cm (4 inches) from walls or other obstructions.
- Handling: The unit is heavy (163.03 kg). Use appropriate lifting equipment and personnel during installation to prevent injury.
- Refrigerant: This unit uses R600a refrigerant, which is flammable. Do not damage the refrigerant circuit. In case of damage, ventilate the area immediately and contact qualified service personnel.
- Cleaning: Use only mild, non-abrasive cleaning agents. Do not use water jets or steam cleaners directly on the unit.
- Authorized Personnel: Repairs and servicing should only be performed by qualified technicians.
3. Setup
Follow these steps for initial setup of your refrigerated table:
- Unpacking: Carefully remove all packaging materials. Inspect the unit for any shipping damage. Report any damage to your supplier immediately.
- Placement: Place the refrigerated table in its desired location, ensuring it is on a firm, level surface. Allow sufficient space for air circulation around the condenser unit (located on the right side).
- Leveling: Adjust the stainless steel feet to ensure the unit is perfectly level. This is crucial for proper drainage and efficient operation.
- Initial Cleaning: Before first use, clean the interior and exterior surfaces with a mild detergent and warm water. Rinse thoroughly and dry completely.
- Power Connection: Connect the unit to a grounded 230V/50Hz power outlet. Do not switch on the unit immediately after moving; allow it to stand upright for at least 2-4 hours to allow the refrigerant to settle.

Figure 3.1: Dimensions of the KTJ187ND6 Refrigerated Table. This image illustrates the external dimensions of the unit: 1795mm length, 700mm depth, and 850mm height, crucial for planning placement.
4. Operating Instructions
The KTJ187ND6 Refrigerated Table is equipped with a digital thermostat for precise temperature control.
4.1. Digital Thermostat Operation

Figure 4.1: Digital Thermostat and Control Panel. This close-up shows the digital display for temperature, control buttons (up, down, set), and power switches for the unit.
- Power On/Off: Use the main power switch (usually indicated by a green light) on the control panel to turn the unit on or off.
- Setting Temperature:
- Press the 'SET' button once. The current set temperature will flash on the display.
- Use the 'Up' or 'Down' arrow buttons to adjust the temperature to your desired value (range: -2°C to 8°C).
- Press 'SET' again to confirm the new temperature. The display will return to showing the actual internal temperature.
- Automatic Defrost: The unit features an automatic defrost function. This process occurs periodically to prevent ice buildup on the evaporator coils. During defrost, the internal temperature may temporarily rise slightly.
- Cooling System: The unit utilizes both static and ventilated cooling for efficient and uniform temperature distribution within the compartment.
4.2. Loading the Drawers
The refrigerated table is equipped with 6 GN 1/1 size drawers. Ensure food items are properly sealed or covered to maintain hygiene and prevent cross-contamination. Do not overload the drawers, as this can impede air circulation and cooling efficiency.

Figure 4.2: Open Drawer with GN Containers. This image shows a partially open drawer, illustrating the compatibility with standard GN 1/1 containers for organized storage of food items.
5. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your refrigerated table.
5.1. Daily Cleaning
- Interior: Wipe down the interior surfaces and drawers with a soft cloth dampened with a mild, food-safe detergent solution. Rinse with clean water and dry thoroughly to prevent odors and bacterial growth. The rounded inner corners facilitate easy cleaning.
- Exterior: Clean the exterior stainless steel surfaces with a damp cloth and a suitable stainless steel cleaner. Avoid abrasive cleaners or scouring pads that can scratch the finish.
5.2. Monthly Maintenance
- Condenser Coil Cleaning: The condenser coils can accumulate dust and debris, reducing cooling efficiency. Carefully clean the condenser coils (located behind the right-side grille) using a soft brush or vacuum cleaner. Ensure the unit is unplugged before performing this task.
- Door Gaskets: Inspect door gaskets for any signs of wear, tears, or damage. Clean them with warm, soapy water to maintain a tight seal. Replace damaged gaskets promptly to prevent energy loss.
6. Troubleshooting
Before contacting service, please check the following common issues:
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit not cooling | No power; thermostat set too high; condenser coils dirty; door not sealed properly. | Check power connection; adjust thermostat; clean condenser coils; inspect and clean door gaskets. |
| Excessive noise | Unit not level; fan obstruction; loose components. | Adjust leveling feet; check for obstructions around fan; contact service if noise persists. |
| Water on floor | Drain line clogged; unit not level. | Clear drain line; adjust leveling feet. |
| Temperature too high | Overloaded unit; frequent door opening; hot ambient temperature. | Reduce load; minimize door openings; ensure proper ventilation. |
If problems persist after attempting these solutions, please contact GGM Gastro customer support.
7. Specifications
Detailed technical specifications for the GGM Gastro KTJ187ND6 Refrigerated Table:
| Feature | Specification |
|---|---|
| Brand | GGM Gastro |
| Model Number | KTJ187ND6 |
| Product Dimensions (L x D x H) | 179.5 cm x 70 cm x 85 cm |
| Weight | 163.03 kg |
| Capacity | 417 Liters |
| Temperature Range | -2°C to 8°C |
| Refrigerant | R600a (CFC-free) |
| Insulation Thickness | 60mm Polyurethane |
| Material (Exterior/Interior) | AISI 304 Stainless Steel (0.70mm thickness) |
| Number of Drawers | 6 (GN 1/1 size) |
| Power Consumption | 275 Watts |
| Electrical Connection | 1N/PE 230V/50Hz |
| Adjustable Temperature Control | Yes |
8. Warranty and Support
For warranty information, spare parts availability, or technical support, please contact GGM Gastro directly or your authorized dealer. Please have your model number (KTJ187ND6) and purchase date available when contacting support.
While specific spare parts availability information is not provided, GGM Gastro offers specialized customer support to assist with any product-related inquiries.