1. Introduction
This manual provides essential information for the safe and efficient operation of the Srliya 1.1kW Mini Motor Inverter Variable Frequency Drive (VFD) Converter, Model UX-52-100-1.1kW. Please read this manual thoroughly before installation, operation, or maintenance to ensure proper usage and prevent potential hazards.
2. Safety Instructions
WARNING: Improper installation or operation can lead to serious injury or death. Always follow local electrical codes and safety regulations.
- Ensure the power supply is disconnected before any wiring or maintenance.
- Only qualified personnel should install, operate, and maintain this device.
- Verify input voltage matches the device specifications (176-264V).
- Do not touch internal components immediately after power-off, as residual voltage may be present.
- Install the VFD in a dry, well-ventilated area, away from direct sunlight, corrosive gases, and excessive vibration.
- Ensure proper grounding of the unit.
3. Product Overview
The Srliya 1.1kW Mini Motor Inverter is a compact variable frequency drive designed for precise motor speed control. It converts single-phase input power to three-phase output power, offering flexibility for various motor applications.
3.1 Key Features
- Power Output: 1.1kW, 6A
- Input Voltage: 176-264V AC, 50/60Hz
- Output Voltage: 0-220V AC
- Frequency Range: 0.1-400Hz
- Control Modes: V/F control, vector control, output torque control
- Display: External LED digital display panel
- Construction: PC flame retardant casing, copper core coils
3.2 Component Identification

The front panel features a digital display for showing operational parameters, control buttons for programming and operation, and a rotary potentiometer for manual frequency adjustment.

The side of the unit provides clearly labeled terminals for power input, motor output, and control signals. Refer to the wiring diagram in the Setup section for detailed connections.

This diagram provides the necessary dimensions for mounting and installation planning.
4. Specifications
| Parameter | Value |
|---|---|
| Model | UX-52-100-1.1kW |
| Input Voltage | 176-264V AC |
| Input Frequency | 50/60Hz |
| Output Voltage | 0-220V AC |
| Output Power | 1.1kW |
| Output Current | 6A |
| Frequency Range | 0.1-400Hz |
| Control Modes | V/F control, vector control, output torque control |
| Material | PC Flame Retardant |
| Dimensions (Approx.) | 102mm (H) x 60mm (W) x 147mm (D) |
| Weight (Approx.) | 13.76 ounces (390g) |
5. Setup and Installation
5.1 Mounting
Mount the VFD vertically on a stable surface, ensuring adequate clearance for ventilation. Refer to Figure 3.2.3 for mounting dimensions. Avoid mounting in areas with excessive heat, dust, or moisture.
5.2 Wiring Connections
CAUTION: Ensure all power is disconnected before performing any wiring. Incorrect wiring can damage the unit or connected equipment.

- Power Input (AC, AC): Connect your 176-264V AC single-phase power supply to the terminals labeled "AC" and "AC". Ensure proper polarity if specified by your power source, though for AC, it's typically non-polar.
- Motor Output (U, V, W): Connect the three-phase motor wires to the terminals labeled "U", "V", and "W". The phase sequence may affect motor rotation direction; if incorrect, swap any two output phases.
- Ground (FG): Connect the frame ground (FG) terminal to a reliable earth ground. This is crucial for safety.
- Control Terminals (Optional): The green terminal block provides connections for external control signals (e.g., RS+, RS- for communication, X1-X4 for digital inputs, V+ for analog input, COM for common). Refer to the full product manual for detailed programming and external control options.
After connecting the circuit, double-check all connections for tightness and correctness before applying power.
6. Operating Instructions
The VFD can be operated via its front panel controls. The basic operation involves setting the desired frequency and starting/stopping the motor.
6.1 Front Panel Controls

- Digital Display: Shows current frequency, output voltage, current, or error codes.
- PROG Button: Enters/exits parameter setting mode.
- UP/DOWN Buttons: Navigate through parameters or adjust values.
- OK Button: Confirms parameter selection or value.
- RUN Button: Starts the motor.
- STOP Button: Stops the motor.
- FWD/REV Buttons: Changes motor rotation direction (if configured).
- Rotary Knob: Adjusts the output frequency (speed) manually.
6.2 Basic Operation Steps
- Power On: Apply power to the VFD. The digital display will illuminate.
- Set Frequency: Use the rotary knob to set the desired output frequency. The display will show the current frequency setting. Alternatively, use the PROG button to enter parameter mode and set frequency digitally.
- Start Motor: Press the RUN button. The motor will accelerate to the set frequency.
- Adjust Speed: While the motor is running, you can adjust the rotary knob to change the motor speed.
- Stop Motor: Press the STOP button. The motor will decelerate and stop.
- Change Direction: If configured, press the FWD or REV buttons to change the motor's rotation direction.
For advanced parameter settings and control modes (V/F control, vector control, output torque control), refer to the comprehensive programming guide typically provided with the full product documentation.
7. Maintenance
WARNING: Disconnect all power before performing any maintenance or cleaning.
- Cleaning: Regularly clean the exterior of the VFD with a soft, dry cloth. Do not use liquid cleaners or solvents. Ensure ventilation openings are free from dust and debris.
- Inspection: Periodically inspect wiring connections for tightness and signs of wear or damage. Check for any unusual noises or odors during operation.
- Environment: Maintain the operating environment within specified temperature and humidity ranges to ensure optimal performance and longevity.
8. Troubleshooting
This section addresses common issues you might encounter. For more complex problems, consult a qualified technician or the manufacturer.
| Problem | Possible Cause | Solution |
|---|---|---|
| VFD does not power on. | No input power; incorrect wiring; internal fuse blown. | Check power supply and connections. Verify input voltage. Consult a technician for internal issues. |
| Motor does not run. | VFD not in RUN mode; frequency set to 0; motor wiring incorrect; overload. | Press RUN button. Adjust frequency knob. Check motor wiring (U, V, W). Check for motor overload. |
| Motor runs in wrong direction. | Incorrect motor phase sequence. | Swap any two of the U, V, W output wires to the motor (after disconnecting power). |
| VFD displays an error code. | Overcurrent, overvoltage, undervoltage, overheat, etc. | Refer to the full product manual for specific error code meanings and solutions. Address the underlying cause (e.g., reduce load, check ventilation). |
9. Warranty and Support
Specific warranty information for the Srliya 1.1kW Mini Motor Inverter (Model UX-52-100-1.1kW) is not provided in this document. Please refer to the product packaging, purchase documentation, or contact the retailer/manufacturer directly for warranty details and technical support.
For further assistance, please visit the official Srliya website or contact their customer service department.