FSP Champ Tower 2K Double-Conversion Online UPS User Manual

Model: PPF16A1919

1. Introduction

This manual provides essential information for the safe and efficient operation of your FSP Champ Tower 2K Double-Conversion Online Uninterruptible Power Supply (UPS). Please read this manual thoroughly before installation and operation, and retain it for future reference.

1.1 Safety Information

  • Always connect the UPS to a grounded power outlet.
  • Do not open the UPS casing. There are no user-serviceable parts inside. Refer all servicing to qualified personnel.
  • Do not block ventilation openings. Ensure adequate airflow around the UPS.
  • Avoid installing the UPS in areas with excessive dust, humidity, or extreme temperatures.
  • Disconnect the UPS from the AC power source before performing any maintenance or cleaning.

2. Package Contents

Verify that all items listed below are included in your package. If any items are missing or damaged, contact your dealer immediately.

  • FSP Champ Tower 2K UPS Unit
  • User Manual (this document)
  • USB Communication Cable
  • RS232 Communication Cable
  • Power Cord (region specific)
  • Output Power Cords (quantity may vary)

3. Product Overview

3.1 Front Panel

Front view of the FSP Champ Tower 2K UPS with LCD display and control buttons.

Image 3.1: Front view of the FSP Champ Tower 2K UPS. This image displays the main unit from the front, highlighting the LCD control panel, ventilation grilles, and the FSP logo at the top.

The front panel features an LCD display that provides real-time status information, including input/output voltage, battery level, load level, and operational mode. Control buttons allow for navigation through the display menus and configuration settings.

3.2 Rear Panel

Rear view of the FSP Champ Tower 2K UPS showing input, output, and communication ports.

Image 3.2: Rear view of the FSP Champ Tower 2K UPS with IEC outlets. This image shows the back of the UPS, featuring the main power input, multiple IEC C13 output receptacles, a circuit breaker, USB and RS232 communication ports, and an intelligent slot for optional network cards.

The rear panel includes:

  • Input: Main AC power input (10A max).
  • Output: Multiple IEC C13 receptacles for connecting protected equipment.
  • Circuit Breaker: Overload protection.
  • USB Port: For connecting to a computer for monitoring and management.
  • RS232 Port: Serial communication port for monitoring.
  • Intelligent Slot: For optional SNMP card or other communication accessories.

Note: Some regional versions may feature different output receptacles, such as Schuko outlets, as shown in the alternative rear panel image.

Alternative rear view of the FSP Champ Tower 2K UPS showing Schuko output ports.

Image 3.3: Alternative rear view of the FSP Champ Tower 2K UPS with Schuko outlets. This image illustrates a regional variant of the UPS rear panel, featuring two Schuko type F output receptacles instead of IEC C13 outlets.

4. Setup

4.1 Placement

  • Place the UPS on a flat, stable surface.
  • Ensure at least 20 cm (8 inches) of clearance around the ventilation openings.
  • Avoid direct sunlight, heat sources, and areas with high humidity or corrosive gases.

4.2 Connecting to Power

  1. Connect the supplied power cord to the UPS input receptacle.
  2. Plug the other end of the power cord into a grounded wall outlet.
  3. Allow the UPS to charge for at least 8 hours before initial use to ensure optimal battery performance.

4.3 Connecting Equipment

  1. Ensure all equipment to be connected is turned off.
  2. Connect your critical equipment (computers, monitors, network devices) to the UPS output receptacles using the provided output power cords.
  3. Do not connect laser printers or other high-surge devices to the UPS output, as this may overload the unit.

5. Operating Instructions

5.1 Powering On the UPS

  1. Press and hold the "ON/MUTE" button on the front panel for approximately 3 seconds until you hear a beep.
  2. The UPS will perform a self-test, and the LCD display will illuminate, showing the current status.

5.2 Powering Off the UPS

  1. Ensure all connected equipment is safely shut down.
  2. Press and hold the "OFF/ENTER" button on the front panel for approximately 3 seconds until the UPS powers down.
  3. To completely disconnect power, unplug the UPS from the wall outlet.

5.3 LCD Display and Control Buttons

The LCD display provides detailed information about the UPS status. Use the "SELECT" button to cycle through different display parameters (e.g., input voltage, output voltage, battery capacity, load level). The "ON/MUTE" button can also silence alarms, and "OFF/ENTER" confirms selections in menu mode.

6. Maintenance

6.1 Battery Care

  • To maintain optimal battery life, keep the UPS connected to AC power at all times.
  • Perform a battery self-test periodically (refer to the advanced settings in the LCD menu or software).
  • Battery replacement should only be performed by qualified service personnel.

6.2 Cleaning

  • Ensure the UPS is turned off and disconnected from AC power before cleaning.
  • Use a soft, dry cloth to wipe the exterior of the UPS.
  • Do not use liquid or aerosol cleaners, as they may damage the unit.
  • Periodically clean the ventilation grilles to prevent dust buildup.

7. Troubleshooting

Common Issues and Solutions
ProblemPossible CauseSolution
UPS does not turn on.No AC input power. Battery deeply discharged.Check AC power connection. Ensure the UPS is plugged into a live outlet. Allow UPS to charge for several hours.
UPS beeps continuously.Overload condition. Battery low/fault.Reduce connected load. Check battery status on LCD. Contact service if battery fault persists.
UPS switches to battery mode frequently.Unstable input power. Sensitivity setting too high.Check AC power quality. Adjust UPS input sensitivity via LCD menu or software (if available).
Connected equipment not receiving power.UPS output off. Circuit breaker tripped.Ensure UPS is on. Check and reset the circuit breaker on the rear panel.

For issues not listed here, or if problems persist, please contact FSP technical support.

8. Specifications

FSP Champ Tower 2K UPS (Model: PPF16A1919)
Model NameChamp Tower 2K
Model NumberPPF16A1919
Capacity2 kVA / 1800 W
Input Voltage(Standard range, typically 110-300 VAC depending on region)
Output Voltage(Configurable, typically 208/220/230/240 VAC)
WaveformPure Sine Wave
Transfer Time0 ms (Online Double-Conversion)
Battery TypeSealed Lead-Acid, Maintenance-Free
Recharge TimeTypically 4-8 hours to 90% capacity
Communication PortsUSB, RS232, Intelligent Slot
Dimensions (H x W x D)(Specific dimensions not provided in source, typical for 2kVA tower UPS)
Weight(Specific weight not provided in source, typically 15-25 kg for 2kVA)

Note: Specifications are subject to change without notice. Refer to the product label for exact details.

9. Warranty and Support

FSP products are designed for reliability and performance. This product is covered by a limited warranty. Please refer to the warranty card included with your product or visit the official FSP website for detailed warranty terms and conditions.

9.1 Technical Support

For technical assistance, troubleshooting, or service inquiries, please contact FSP customer support through their official website or the contact information provided in your warranty documentation.

FSP Official Website: www.fsp-group.com

Related Documents - Champ Tower 2K

PreviewFSP Online UPS 1K/2K/3K Руководство пользователя
Руководство пользователя для источников бесперебойного питания FSP Online UPS серий 1K, 2K и 3K. Содержит инструкции по установке, эксплуатации и техническому обслуживанию.
PreviewFSP Online UPS 1K/2K/3K Användarguide och Specifikationer
Denna guide ger detaljerade instruktioner för installation, drift och underhåll av FSP Online UPS-modellerna 1K, 2K och 3K. Innehåller säkerhetsvarningar, tekniska specifikationer och felsökningsinformation.
PreviewFSP Online UPS 1K/2K/3K: User Manual and Technical Specifications
This manual provides comprehensive guidance for FSP Online UPS models 1K, 2K, and 3K, covering safety precautions, installation, operation, maintenance, troubleshooting with error codes, and detailed technical specifications for both Tower and Rack configurations.
PreviewFSP Online UPS 1K/2K/3K Felhasználói Kézikönyv és Útmutató
Ez a dokumentum az FSP Online UPS 1K, 2K és 3K sorozat biztonságos és hatékony üzemeltetéséhez nyújt alapvető információkat. Részletezi a fontos biztonsági óvintézkedéseket, a lépésről lépésre történő telepítési eljárásokat és a helyes használatra vonatkozó útmutatásokat. A felhasználók átfogó utasításokat találnak az UPS csatlakoztatásához, működési módjainak megértéséhez és az alapvető karbantartás elvégzéséhez. Az útmutató továbbá ismerteti a hibaelhárítási lépéseket és az FSP Online UPS modellek műszaki specifikációit.
PreviewFSP Online UPS 1K/2K/3K: Manuál a Bezpečnostní Pokyny
Komplexní průvodce pro online UPS jednotky FSP řady 1K, 2K a 3K. Zahrnuje bezpečnostní varování, podrobné pokyny k instalaci, provozu, údržbě a technické specifikace pro zajištění optimálního výkonu a bezpečnosti.
PreviewFSP Online UPS 1K/2K/3K User Manual
Comprehensive user manual for FSP Online UPS models 1K, 2K, and 3K, covering safety precautions, installation, operation, maintenance, and technical specifications.