1. Introduction

This manual provides essential information for the safe and efficient operation of your Aquagem InverEco Variable Speed Pool Pump. Please read this manual thoroughly before installation and operation to ensure proper use and maintenance.

Aquagem InverEco Variable Speed Pool Pump

Figure 1: Aquagem InverEco Variable Speed Pool Pump. This image shows the black-colored pump unit with its motor housing on the left, featuring a digital display and control buttons, and the pump wet end on the right, including the strainer basket housing with a clear lid and pipe connections.

2. Safety Information

Always observe basic safety precautions when installing and operating this electrical equipment. Failure to do so could result in serious injury or death.

  • Ensure the power supply is disconnected before performing any maintenance or installation.
  • Installation must be performed by a qualified electrician and in accordance with all local and national electrical codes.
  • Do not operate the pump if it is damaged or if the power cord is frayed.
  • Keep children and unauthorized persons away from the pump during operation.
  • The pump is designed for pool water circulation only. Do not use it for other liquids.
  • Ensure proper ventilation around the pump to prevent overheating.

3. Product Components

The Aquagem InverEco Variable Speed Pool Pump consists of the following main components:

  • Motor Unit: Houses the variable speed motor and control electronics.
  • Control Panel: Digital display and buttons for setting parameters and monitoring operation.
  • Pump Wet End: Includes the impeller, volute, and strainer basket housing.
  • Strainer Basket: Collects debris before it enters the pump.
  • Clear Lid: Allows visual inspection of the strainer basket.
  • Inlet/Outlet Ports: 2"F threaded connections for plumbing.
  • Power Cable: 2m power cable included for connection to power supply.
  • Digital Input Cable: 2.5m cable for external control.

4. Setup and Installation

Proper installation is crucial for the pump's performance and longevity.

  1. Location: Install the pump in a dry, well-ventilated area, protected from direct sunlight and extreme weather. Ensure it is as close to the pool as possible and below water level for optimal priming.
  2. Mounting: Secure the pump to a solid, level surface to minimize vibration and noise.
  3. Plumbing: Connect the pool's suction line to the pump's inlet and the return line to the pump's outlet using 2"F fittings. Ensure all connections are watertight.
  4. Electrical Connection:
    • The pump operates on a single-phase power supply.
    • Connect the included 2m power cable to a suitable grounded electrical outlet, protected by a Residual Current Device (RCD).
    • If using the digital input for external control, connect the 2.5m digital input cable as per your control system's instructions.
  5. Priming: Before first use, fill the strainer basket housing with water to prime the pump. Ensure the clear lid is securely tightened.

5. Operating Instructions

The InverEco pump offers advanced features for efficient pool management.

5.1. Control Panel Overview

The digital display shows current operating status, including instant power consumption. Buttons allow for speed adjustment and timer settings.

5.2. Variable Speed Operation

  • The pump's operating capacity can be adjusted from 30% to 100%.
  • Use the control panel buttons to increase or decrease the motor speed to achieve desired flow rates and energy savings.
  • The soft start protection feature ensures a gradual ramp-up of the motor, extending its lifespan.

5.3. Filtration Timers

  • Set up to 4 daily filtration timers for automated operation.
  • Each timer can be programmed with specific start/end times and desired operating speed.
  • Refer to the detailed programming section in the full manual for step-by-step instructions.

5.4. Backwash Function

  • The pump features a convenient one-button backwash function.
  • Before initiating backwash, ensure your multi-port valve is set to the "Backwash" position.
  • Press the dedicated backwash button on the control panel to start the backwash cycle.
  • Monitor the sight glass on your filter until the water runs clear, then stop the backwash cycle and return the valve to "Filter" or "Rinse" as needed.

6. Maintenance

Regular maintenance ensures optimal performance and extends the life of your pump.

  • Strainer Basket Cleaning: Regularly inspect and clean the strainer basket. Turn off the pump, release pressure, remove the clear lid, empty debris, and rinse the basket.
  • Lid O-Ring: Inspect the lid O-ring for cracks or wear. Lubricate with a silicone-based lubricant as needed to maintain a watertight seal.
  • Winterization: In cold climates, drain the pump completely and store it in a frost-free environment during winter months to prevent damage from freezing water.
  • General Cleaning: Keep the exterior of the pump clean and free of debris. Do not spray water directly onto the motor or control panel.

7. Troubleshooting

This section addresses common issues you might encounter.

ProblemPossible CauseSolution
Pump does not startNo power; tripped circuit breaker; motor overload.Check power supply; reset breaker; allow motor to cool and restart.
Low water flowClogged strainer basket; air leak in suction line; dirty filter.Clean strainer basket; check for air leaks; backwash/clean filter.
Pump making unusual noiseAir in system; cavitation; worn bearings.Bleed air from system; ensure adequate water supply; contact support if noise persists.

For issues not listed here, please contact Aquagem customer support.

8. Specifications

FeatureDetail
ModelInverEco
BrandAquagem
Power0.75 kW
Max Flow Rate18 m³/h (at 8 mwc - 3000 rpm)
Operating Capacity30% to 100%
Fittings Dimension2"F
PhaseSingle-phase
Power Cable Length2 m
Digital Input Cable Length2.5 m
ASINB0D224G9X6

9. Warranty and Support

Aquagem provides the following warranty for your InverEco Variable Speed Pool Pump:

  • Standard Warranty: 2 years on the pump unit.
  • Motor Warranty: 4 years on the motor component.

For warranty claims, technical support, or spare parts inquiries, please contact Aquagem customer service. Keep your proof of purchase for warranty validation.

For more information, visit the official Aquagem website or contact your local dealer.

© 2024 Aquagem. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.