VOXON VX-WA806

VOXON Door and Window Alarm System User Manual

Model: VX-WA806

Ten white VOXON door and window alarm units, each consisting of a main alarm unit and a smaller magnetic sensor.

Image: Ten white VOXON door and window alarm units, each consisting of a main alarm unit and a smaller magnetic sensor, ready for installation.

1. Introduction

Thank you for choosing the VOXON Door and Window Alarm System. This manual provides essential information for the safe and effective use of your new security alarms. Please read these instructions carefully before installation and retain them for future reference. This system is designed to enhance security by detecting unauthorized entry through doors or windows, providing an audible alert.

2. Package Contents

Each VOXON Door and Window Alarm System package includes the following components:

  • VOXON Alarm Units (Quantity as per pack, e.g., 10 units for 10PC)
  • Magnetic Sensors (Matching quantity to alarm units)
  • LR44 Batteries (Pre-installed in each unit)
  • Double-sided Adhesive Tapes (For mounting)

3. Product Components

Familiarize yourself with the main parts of the alarm unit:

Diagram showing the components of the VOXON door alarm: main unit with speaker, magnetic sensor, battery compartment, mounting plate, and OFF/CHIME/ALARM switch.

Image: Exploded view of the VOXON alarm, highlighting the magnet, main alarm unit, battery compartment, mounting plate, and the OFF/CHIME/ALARM switch.

  • Main Alarm Unit: Contains the speaker, battery, and control switch.
  • Magnetic Sensor: A smaller unit that works in conjunction with the main alarm.
  • OFF/CHIME/ALARM Switch: Located on the side of the main unit to select operating mode.
  • Battery Compartment: Located on the back of the main unit.
  • Mounting Plate: Integrated into the back of the main unit for adhesive attachment.

4. Setup and Installation

Follow these steps for proper installation of your VOXON Door and Window Alarm:

  1. Prepare the Surface: Ensure the mounting surface on your door, window, or frame is clean, dry, and smooth. Wipe away any dust or grease.
  2. Attach Adhesive Tapes: Peel the protective backing from one side of the double-sided adhesive tape and firmly apply it to the back of the main alarm unit and the magnetic sensor.
  3. Position the Units:
    • Place the main alarm unit on the door or window frame.
    • Place the magnetic sensor on the moving part of the door or window, directly adjacent to the main alarm unit.
  4. Ensure Correct Alignment: Align the arrows on both the main alarm unit and the magnetic sensor. The two units must be positioned so that the gap between them is less than 0.78 inches (2 cm) when the door or window is closed.
  5. Secure the Units: Once aligned, peel the remaining protective backing from the adhesive tapes and firmly press both units onto the prepared surface for at least 30 seconds.
Three-step diagram showing how to install the VOXON door alarm: 1. Clean the surface, 2. Apply adhesive tape to the back of the alarm, 3. Attach the alarm to the door frame.

Image: Visual guide for easy installation, showing cleaning the surface, applying adhesive, and mounting the alarm on a door frame.

Diagram illustrating correct and incorrect installation of the VOXON door alarm. The correct method shows arrows aligned and a gap less than 0.78 inches. The incorrect method shows misaligned arrows and a gap greater than 0.78 inches.

Image: Detailed illustration of the correct installation method, emphasizing arrow alignment and maintaining a gap of less than 0.78 inches (2 cm) between the alarm and magnet.

Important: The alarm will only function correctly if the main unit and magnetic sensor are aligned with their arrows and the gap between them is less than 0.78 inches (2 cm) when the door/window is closed.

5. Operating Instructions

The VOXON Door and Window Alarm features a simple three-position switch for operation:

  • OFF: In this position, the alarm is deactivated. No sound will be produced when the door or window opens.
  • CHIME: When set to CHIME, the alarm will emit a pleasant chime sound each time the door or window is opened. This mode is suitable for monitoring entry/exit without a loud alarm.
  • ALARM: In ALARM mode, if the door or window is opened (separating the main unit and magnet by more than 0.78 inches / 2 cm), a loud 100dB siren will sound continuously until the door or window is closed again.
Diagram showing a VOXON door alarm and magnetic sensor on a door frame, with a speech bubble indicating '100 decibel chime or alarm will trigger when magnet separates from base more than 0.78 inches'.

Image: Illustration demonstrating the alarm activation when the magnetic sensor separates from the main unit by more than 0.78 inches, triggering a 100dB sound.

To select a mode, simply slide the switch on the side of the main alarm unit to your desired setting.

6. Maintenance

  • Battery Replacement: The alarms are powered by LR44 batteries. If the alarm volume decreases or the unit stops functioning, it may be time to replace the batteries. To replace, carefully open the battery compartment on the back of the main unit, remove the old batteries, and insert new LR44 batteries, ensuring correct polarity.
  • Cleaning: Use a soft, dry cloth to clean the alarm units. Do not use abrasive cleaners or solvents, as these can damage the casing or internal components.
  • Adhesive Check: Periodically check the adhesive tapes to ensure the units remain securely attached to the surface. Reapply or replace adhesive if necessary.

7. Troubleshooting

ProblemPossible CauseSolution
Alarm does not sound when door/window opens.
  • Switch is in "OFF" position.
  • Batteries are low or depleted.
  • Alarm and magnet are misaligned or too far apart.
  • Slide switch to "CHIME" or "ALARM".
  • Replace LR44 batteries.
  • Realign units, ensuring gap is less than 0.78 inches (2 cm) and arrows match.
Alarm sounds continuously or falsely triggers.
  • Alarm and magnet are too far apart when door/window is closed.
  • Loose mounting.
  • Adjust position to ensure gap is less than 0.78 inches (2 cm) when closed.
  • Re-secure units with fresh adhesive tape.
Alarm volume is low.Batteries are low.Replace LR44 batteries.

8. Specifications

  • Model Number: VX-WA806
  • Brand: VOXON
  • Noise Level: 100 Decibels
  • Maximum Detection Range: 0.78 Inches (2 cm)
  • Control Method: Touch (Slide Switch)
  • Mounting Type: Door Mount (Adhesive)
  • Sensor Technology: Contact Sensor
  • Power Source: Battery Powered
  • Battery Type: LR44 Alkaline (Included)
  • Product Dimensions: Approximately 3 x 2 x 4 inches (Main Unit)
  • Item Weight: Approximately 15.1 ounces (for the pack of 10)

9. Warranty and Support

VOXON provides a 36-month worry-free warranty for this product. If you encounter any issues or have questions regarding your Door and Window Alarm System, please do not hesitate to contact our customer service. Our friendly support team is available to assist you.

For support, please refer to the contact information provided with your purchase or visit the official VOXON website.

Related Documents - VX-WA806

Preview VOXON VX-WD878 / VX-WD888 Wireless Doorbell User Manual
User manual for the VOXON VX-WD878 and VX-WD888 wireless doorbells, providing setup instructions, product specifications, safety guidelines, and warranty information.
Preview Tannoy VX Series Professional Loudspeakers Operation Manual
This operation manual provides detailed information on the Tannoy VX Series of professional loudspeakers, covering installation, operation, safety, and technical specifications. Learn about the Dual Concentric driver technology, bi-amp configuration, rigging procedures, and maintenance for models like VX 5.2, VX 6, VX 8, VX 8M, VX 8.2, VX 12, VX 12HP, VX 12Q, VX 12.2Q, VX 15HP, and VX 15Q.
Preview FOSCAM Outdoor HD IP Camera User Manual
Comprehensive user manual for the FOSCAM Outdoor HD IP Camera, detailing setup, hardware connection, software installation, network configuration, advanced settings, and troubleshooting for models like G2, G4, FI9900P, FC5618P, and more.
Preview Tannoy VX Series Loudspeaker Quick Start Guide
Quick start guide for Tannoy VX Series loudspeakers, covering safety instructions, system requirements, amplifier considerations, connections, mounting, and technical specifications.
Preview Aerocool VX PLUS/VX PLUS RGB Series Power Supply User Manual
Comprehensive user manual for Aerocool VX PLUS and VX PLUS RGB series power supply units. It covers product overview, safety instructions, installation procedures, troubleshooting steps, technical specifications, warranty details, and manufacturer contact information. Designed for PC builders and upgraders, these PSUs offer reliable power with low noise.