Marhynchus KB1

Marhynchus KB1 PM2.5 Air Quality Monitor User Manual

Model: KB1

1. Product Overview

The Marhynchus KB1 Air Quality Monitor is designed to provide real-time monitoring of indoor air quality. It accurately detects particulate matter (PM2.5, PM1.0, PM10), temperature, and humidity, ensuring a healthier indoor environment. Its compact and portable design, coupled with an easy-to-read LED display, makes it suitable for various settings including homes, offices, and schools.

Marhynchus KB1 Air Quality Monitor displaying PM2.5, PM1.0, PM10, temperature, and humidity readings.

Figure 1: Marhynchus KB1 Air Quality Monitor with its display showing various air quality parameters and a USB-C charging cable.

2. Package Contents

  • 1 x Marhynchus KB1 Air Quality Monitor
  • 1 x USB Type-C Charging Cable
  • 1 x English User Manual

3. Device Layout

Familiarize yourself with the key components of your Marhynchus KB1 Air Quality Monitor.

Side view of Marhynchus KB1 Air Quality Monitor showing the USB-C charging port and a small indicator light.

Figure 2: Side view of the monitor, highlighting the USB Type-C charging port.

  • Display Screen: Shows real-time readings for PM2.5, PM1.0, PM10, temperature, humidity, and AQI.
  • Power Button: Located on the side (exact position may vary).
  • USB Type-C Port: For charging the internal battery.
  • Air Inlet/Outlet Vents: Located on the sides/back for air circulation to sensors.

4. Setup

4.1 Charging the Device

  1. Connect the provided USB Type-C charging cable to the charging port on the side of the monitor.
  2. Connect the other end of the USB cable to a standard USB power adapter (not included) or a computer's USB port.
  3. The battery indicator on the display will show charging status. A full charge typically takes approximately 2-3 hours.
  4. Ensure the device is fully charged before first use for optimal battery performance.

4.2 Powering On/Off

  • To Power On: Press and hold the Power button (usually located on the side) for a few seconds until the display illuminates.
  • To Power Off: Press and hold the Power button again for a few seconds until the display turns off.

5. Operating Instructions

5.1 Real-time Monitoring

Once powered on, the monitor will automatically begin detecting and displaying current air quality parameters. Allow a few minutes for the sensors to stabilize and provide accurate readings.

Close-up of the Marhynchus KB1 Air Quality Monitor display showing PM2.5 at 132 (Unhealthy), PM1.0 at 72, PM10 at 142, AQI at 190, Air Temperature at 0°C, and Humidity at 0%.

Figure 3: Detailed view of the monitor's display interface.

  • PM2.5, PM1.0, PM10: Displays the concentration of particulate matter in micrograms per cubic meter (µg/m³). These values indicate the presence of fine particles in the air.
  • AQI (Air Quality Index): Provides an overall assessment of air quality based on the highest pollutant concentration. The display often includes a color-coded bar or text (e.g., "Unhealthy") to indicate the current AQI level.
  • Air Temp: Shows the ambient air temperature in Celsius (°C).
  • Humidity: Displays the relative humidity percentage (%).

5.2 Interpreting Readings

The monitor's display uses color indicators and text to help you quickly understand the air quality status. Refer to standard air quality guidelines for detailed interpretation of PM values and AQI levels.

Note: The device is designed for indoor use. External factors like strong airflow, smoke, or dust can temporarily affect readings.

6. Maintenance

6.1 Cleaning

  • Wipe the device exterior with a soft, dry cloth.
  • Do not use abrasive cleaners, solvents, or immerse the device in water.
  • Keep the air inlet and outlet vents clear of dust and debris to ensure accurate sensor operation.

6.2 Battery Care

  • Charge the device regularly, especially if it will be stored for an extended period, to maintain battery health.
  • Avoid exposing the device to extreme temperatures, which can degrade battery performance.

7. Troubleshooting

ProblemPossible CauseSolution
Device does not power on.Low battery or no charge.Charge the device using the provided USB Type-C cable. Ensure the charging cable and adapter are functioning correctly.
Readings appear inaccurate or fluctuate wildly.
  • Sensors not stabilized.
  • Device placed near strong air currents, smoke, or dust sources.
  • Vents are blocked.
  • Allow a few minutes after powering on for sensors to stabilize.
  • Relocate the device to a stable environment away from direct airflow or pollutant sources.
  • Ensure air inlet/outlet vents are clear.
Display is dim or unresponsive.Low battery.Charge the device. If the issue persists after charging, contact customer support.

8. Specifications

FeatureDetail
ModelKB1
MaterialABS
Battery523450 Lithium 1000mAh (built-in)
Charging PortUSB Type-C
Dimensions (Length x Height)8cm x 8cm (approximate)
Item Weight7.7 ounces (approx. 219g)
Measurement ParametersPM2.5, PM1.0, PM10, Temperature, Humidity, AQI

9. Warranty and Support

9.1 Limited Warranty

Marhynchus products are manufactured to high quality standards. This product is covered by a limited warranty against defects in materials and workmanship from the date of purchase. Please retain your proof of purchase for warranty claims. The warranty does not cover damage caused by misuse, accident, unauthorized modification, or normal wear and tear.

9.2 Customer Support

For technical assistance, troubleshooting, or warranty inquiries, please contact Marhynchus customer support through the retailer where the product was purchased or visit the official Marhynchus website for contact information.

Related Documents - KB1

Preview Bourns POWrFuse PF-K Series EV Power Fuses Datasheet
Technical datasheet for Bourns POWrFuse PF-K Series EV Power Fuses, detailing features, electrical and environmental characteristics, dimensions, ordering information, and performance curves for automotive applications.
Preview Mitsubishi Electric City Multi Indoor Unit Installation Manual
Comprehensive installation manual for Mitsubishi Electric City Multi indoor units and BC controllers, covering safety precautions, site selection, installation procedures, refrigerant and drain piping, electrical work, and test runs.
Preview Mitsubishi Electric City Multi Indoor Unit Installation Manual
Comprehensive installation manual for Mitsubishi Electric City Multi indoor units, covering safety precautions, installation procedures, electrical work, piping, and testing. Includes models CMB-M-V-J1, CMB-M-V-JA1, CMB-M-V-KB1, CMB-P-V-KA1.
Preview GMK NUCBOX KB1 Mini PC User Manual: Specifications, Safety, and FCC Compliance
Comprehensive user manual for the GMK NUCBOX KB1 mini PC, detailing technical specifications, safety precautions, warranty information, and FCC compliance statements.
Preview MAX Music KB1 Electronic Keyboard 61-key User Manual
Comprehensive user manual for the MAX Music KB1 Electronic Keyboard with 61 keys. Learn about setup, controls, features, training modes, recommended apps, and technical specifications.
Preview Yale Kluizen: Veiligheid voor Al Je Waardevolle Bezittingen
Ontdek de uitgebreide collectie Yale kluizen, waaronder brandwerende, gemotoriseerde, slimme en elektronische kluizen. Bescherm je documenten, sieraden en meer met Yale's betrouwbare beveiligingsoplossingen.