1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your True TBB-2G-HC-LD Commercial Back Bar Refrigerator. Please read all instructions carefully before using the appliance to ensure proper function and longevity.
The True TBB-2G-HC-LD is a two-section back bar refrigerator designed for commercial use, featuring two swinging glass doors, a black exterior, and operating on 115V power. It is capable of holding up to 88 six-packs of 12-ounce cans or two half-barrel kegs, maintaining temperatures between 33°F and 38°F using R290 hydrocarbon refrigerant.
2. Safety Information
WARNING: To reduce the risk of fire, electric shock, or injury, always follow basic safety precautions.
- Ensure the unit is connected to a properly grounded 115V/60Hz/1ph electrical outlet with a NEMA 5-15P plug. Do not use extension cords.
- Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
- Keep ventilation openings in the appliance enclosure or in the built-in structure clear of obstruction.
- Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
- Do not damage the refrigerant circuit.
- Only qualified service personnel should perform repairs.
- This appliance is heavy (approximately 395 lbs). Use appropriate lifting techniques and equipment during installation to prevent injury.
3. Unpacking and Installation
3.1 Unpacking
- Carefully remove all packaging materials, including tape and protective film.
- Inspect the refrigerator for any shipping damage. Report any damage immediately to the carrier and your dealer.
- Remove any internal packing materials and accessories.
3.2 Location and Placement
Select a location that is level, stable, and strong enough to support the unit's weight (395 lbs) when fully loaded. Ensure adequate air circulation around the unit.
- Dimensions: 58 7/8" W x 29 7/8" D x 37" H. Allow sufficient clearance for door swing and ventilation.
- Avoid direct sunlight or proximity to heat-generating appliances.
- Ensure the unit is level using a spirit level and adjusting the feet if necessary.
3.3 Electrical Connection
The unit requires a dedicated 115V/60Hz/1ph electrical supply with a 2.8 amp draw and a NEMA 5-15P plug. Do not use adapters or extension cords. Consult a qualified electrician if you are unsure about your electrical supply.
3.4 Initial Cleaning
Before first use, clean the interior and exterior surfaces with a mild detergent and warm water. Rinse thoroughly and dry completely.
4. Operation
4.1 Powering On
After installation and initial cleaning, plug the unit into the dedicated electrical outlet. The compressor will start, and the interior LED lighting will illuminate.
4.2 Temperature Control
The unit is designed to maintain temperatures between 33°F and 38°F. Temperature adjustments are typically managed by a factory-set thermostat. Refer to the digital thermometer for current internal temperature.
4.3 Loading the Refrigerator
The refrigerator can hold up to 88 six-packs of 12-ounce cans or two half-barrel kegs. It features four black PVC-coated shelves, adjustable in 1/2-inch increments, to accommodate various product sizes.

Figure 1: Front view of the True TBB-2G-HC-LD Commercial Back Bar Refrigerator. This image shows the unit with its two glass doors, revealing multiple shelves stocked with various bottled and canned beverages. The black exterior and stainless steel countertop are visible.
4.4 Door Features
- Glass Doors: Double-pane thermal glass provides visibility of products while maintaining insulation.
- Magnetic Gaskets: Ensure a tight seal to prevent cold air loss.
- Door Locks: For securing contents.
- Threshold Protector: Prevents damage to the cabinet when loading or unloading heavy items like kegs.
5. Maintenance and Cleaning
5.1 Regular Cleaning
- Interior: Clean the stainless steel interior floor and walls regularly with a mild, non-abrasive cleaner and warm water. Rinse and dry thoroughly to prevent odors and maintain hygiene.
- Exterior: Wipe down the black laminate vinyl exterior and stainless steel countertop with a damp cloth and mild detergent. Avoid abrasive cleaners that could damage the finish.
- Glass Doors: Use a glass cleaner for streak-free visibility.
- Door Gaskets: Inspect and clean door gaskets regularly to ensure they are free of debris and maintain a proper seal. Replace worn or damaged gaskets promptly.
5.2 Condenser Coil Cleaning
The unit features a reverse condensing fan motor that helps remove debris from the condensing coil. This mechanism activates for 20 seconds each time the compressor turns on, directing air towards the coil to dislodge dirt and dust. While this reduces buildup, regular manual inspection and cleaning are still recommended for optimal efficiency.
- Disconnect power to the unit before cleaning.
- Access the refrigeration system by removing the front grille and sliding it out.
- Use a stiff brush or vacuum cleaner to remove any remaining dust and debris from the condenser coil fins.
- Reinstall the grille and restore power.
6. Troubleshooting
Before contacting service, review the following common issues and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit not cooling | No power; thermostat set too high; condenser coil dirty; door left ajar. | Check power connection and circuit breaker; verify thermostat setting; clean condenser coil; ensure doors are fully closed. |
| Excessive noise | Unit not level; fan obstruction; loose components. | Level the unit; check for obstructions around fan blades; contact service if noise persists. |
| Water on floor (leaking) | Drain line clogged; excessive humidity. | Clear drain line; ensure doors are not left open frequently. |
| Doors not sealing properly | Gaskets dirty or damaged; unit not level. | Clean or replace gaskets; level the unit. |
If troubleshooting steps do not resolve the issue, contact qualified service personnel.
7. Specifications
| Feature | Specification |
|---|---|
| Model | TBB-2G-HC-LD |
| Brand | True |
| Dimensions (W x D x H) | 58 7/8" x 29 7/8" x 37" (1494 mm x 759 mm x 940 mm) |
| Item Weight | 395 lbs |
| Capacity | 88 six-packs (12-oz cans) or 2 half-barrel kegs / 15.5 Gallons |
| Number of Doors | 2 (Swinging Glass Doors) |
| Shelves | 4 (Black PVC-coated, adjustable in 1/2" increments) |
| Refrigerant | R290 Hydrocarbon |
| Temperature Range | 33°F to 38°F |
| Electrical | 115V/60Hz/1ph, 2.8 Amps, 1/4 HP |
| Plug Type | NEMA 5-15P |
| Exterior Finish | Black Laminate Vinyl |
| Interior Finish | Stainless Steel Floor, Galvanized Interior |
| Insulation | Foamed-in-place polyurethane |
| Special Features | LED Interior Lighting, Door Locks, Scratch Resistant, Frost Free Defrost |

Figure 2: Elevation diagram providing front view dimensions of the True TBB-2G-HC-LD refrigerator in inches and millimeters. Key measurements include overall width (58 13/16"), height (37"), and the 3" clearance from the floor.

Figure 3: Plan view diagram illustrating the top-down dimensions of the True TBB-2G-HC-LD refrigerator. It shows the depth (28 13/16") and the swing radius of the two doors when fully open.
8. Warranty and Support
8.1 Warranty Information
This True TBB-2G-HC-LD refrigerator comes with a 7-year Parts & Labor warranty and a 7-year Compressor warranty. Please retain your proof of purchase for warranty claims. The warranty covers defects in materials and workmanship under normal use and service.
8.2 Customer Support
For technical assistance, service requests, or warranty inquiries, please contact your authorized True Refrigeration dealer or the manufacturer's customer service. Have your model number (TBB-2G-HC-LD) and serial number ready when contacting support.