Faber HOOD IRIS BLDC FL HC BK 90

Faber 90cm 1500m³/hr BLDC Motor Autoclean Chimney User Manual

Model: HOOD IRIS BLDC FL HC BK 90

Brand: Faber

1. Introduction

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Faber 90cm 1500m³/hr BLDC Motor Autoclean Chimney. Please read these instructions carefully before using the appliance and retain them for future reference. Proper use and maintenance will ensure optimal performance and longevity of your chimney.

2. Product Overview

The Faber HOOD IRIS BLDC FL HC BK 90 is a wall-mounted kitchen chimney designed for effective smoke and odor extraction. It features a powerful BLDC motor, filterless technology, and convenient control options.

Key Features:

  • BLDC Motor: Offers high efficiency, reduced noise, and extended lifespan.
  • 1500 m³/hr Suction Power: Suitable for kitchens with 4-6 burner stoves.
  • Filterless Technology: Eliminates the need for frequent filter cleaning.
  • Autoclean Feature: Simplifies internal cleaning and maintenance.
  • Built-In Oil Collector: Gathers oil residues for easy disposal.
  • Touch & Gesture Control: Provides intuitive operation with 9 speed settings.
  • LED Lighting: Illuminates the cooking area efficiently.

Product Views:

Front view of the Faber Hood Iris Chimney
Figure 2.1: Front view of the Faber Hood Iris Chimney, showcasing its curved glass design and control panel.
Side view of the Faber Hood Iris Chimney
Figure 2.2: Side view of the Faber Hood Iris Chimney, illustrating its sleek profile and wall-mounted design.
Faber Hood Iris Chimney with BLDC Motor illustration
Figure 2.3: Illustration highlighting the BLDC Motor technology within the Faber Hood Iris Chimney, emphasizing its efficiency and quiet operation.

3. Safety Instructions

Always adhere to the following safety precautions to prevent injury or damage to the appliance.

  • Ensure the electrical supply matches the voltage specified on the rating label.
  • Do not operate the chimney without the oil collector properly installed.
  • Keep children away from the appliance during operation and cleaning.
  • Never flambé under the chimney.
  • Regularly clean the oil collector to prevent fire hazards.
  • Disconnect power before any cleaning or maintenance.
  • Installation must be performed by a qualified technician.

4. Setup and Installation

Proper installation is crucial for the chimney's performance and safety. It is recommended that installation be carried out by a Faber authorized service technician.

4.1 Unpacking

Carefully remove the chimney from its packaging. Inspect for any damage during transit. Retain packaging materials for potential future transport or service.

4.2 Mounting

The chimney is designed for wall-mounted installation. Ensure the wall structure is strong enough to support the chimney's weight. Maintain the recommended distance between the cooking surface and the chimney for optimal suction and safety.

Back view of the Faber Hood Iris Chimney showing mounting points
Figure 4.1: Back view of the Faber Hood Iris Chimney, indicating mounting points and exhaust outlet for installation planning.

4.3 Electrical Connection

Connect the chimney to a grounded electrical outlet. Ensure the power supply is stable and meets the appliance's requirements (240 Volts). Do not use extension cords or adapters.

4.4 Ducting (Optional)

The chimney can be installed with or without a duct. For ducted installation, ensure the ducting is properly sealed and leads to an external vent. For ductless (recirculating) use, a charcoal filter may be required (contact customer support for details).

5. Operating Instructions

Your Faber Hood Iris chimney features intuitive touch and gesture controls for easy operation.

5.1 Control Panel

The control panel is located on the front of the chimney and includes touch-sensitive buttons for various functions.

Faber Hood Iris Chimney with hand demonstrating touch and gesture controls
Figure 5.1: Image illustrating the touch and gesture control interface of the Faber Hood Iris Chimney, showing how to interact with the panel.

5.2 Power On/Off

  • Touch Control: Press the power button on the control panel.
  • Gesture Control: Wave your hand from left to right in front of the motion sensor to turn the chimney ON. Wave from right to left to turn it OFF.

5.3 Adjusting Suction Speed

The chimney offers 9 speed settings for varying cooking needs.

Faber Hood Iris Chimney showing 1500 m³/hr suction power and 9-speed touch switch
Figure 5.2: Display of the Faber Hood Iris Chimney highlighting its 1500 m³/hr suction power and the 9-speed touch switch with motion sensor capabilities.
  • Touch Control: Use the '+' and '-' buttons on the control panel to increase or decrease the fan speed.
  • Gesture Control: Wave your hand from left to right to increase speed. Wave from right to left to decrease speed.

5.4 LED Lighting

Press the light button on the control panel to turn the LED lights ON or OFF, illuminating your cooking area.

5.5 Autoclean Function

The autoclean feature helps maintain the chimney's internal cleanliness. Refer to the maintenance section for details on activating and managing this function.

6. Maintenance

Regular maintenance ensures the longevity and efficient operation of your chimney.

6.1 Autoclean Cycle

The autoclean function uses heat to melt and collect oil residues. It is recommended to run the autoclean cycle periodically, depending on your cooking frequency.

  • To activate, press the 'Autoclean' button on the control panel.
  • The cycle will run for a set duration, after which the chimney will automatically turn off.
  • Ensure the oil collector is empty before starting an autoclean cycle.

6.2 Oil Collector Cleaning

The built-in oil collector gathers oil and grease. It should be emptied and cleaned regularly.

Faber Hood Iris Chimney highlighting filterless design and oil collector
Figure 6.1: View of the Faber Hood Iris Chimney emphasizing its filterless design and the easily accessible built-in oil collector for maintenance.
  • Carefully remove the oil collector from its housing.
  • Empty the collected oil into a suitable container.
  • Wash the oil collector with warm, soapy water. Rinse thoroughly and dry completely before reinserting.

6.3 Exterior Cleaning

Clean the exterior surfaces of the chimney with a soft cloth and mild detergent. Avoid abrasive cleaners or harsh chemicals that could damage the finish.

7. Troubleshooting

If you encounter issues with your chimney, refer to the following table for common problems and solutions.

ProblemPossible CauseSolution
Chimney not turning onNo power supply; loose connectionCheck power cord and circuit breaker. Ensure proper connection.
Low suction powerOil collector full; ducting obstruction (if ducted); incorrect speed settingEmpty and clean oil collector. Check ducting for blockages. Increase fan speed.
Unusual noise during operationLoose components; foreign object in fanTurn off and disconnect power. Inspect for loose parts or obstructions. Contact service if noise persists.
Autoclean not functioningControl panel issue; internal faultEnsure power is stable. If issue persists, contact customer support.

If the problem persists after attempting these solutions, please contact Faber customer support.

8. Specifications

Technical details for the Faber HOOD IRIS BLDC FL HC BK 90 Chimney.

FeatureSpecification
Model Number325.0718.160
TypeCurved Glass | Wall Mounted
Size90 cm
Suction Power1500 m³/hr (Cubic Meters Per Hour)
Filter TypeFilterless
Control TypeTouch Control, Gesture Control, Motion Sensor
Number of Speeds9
Noise Level52 dB
Motor TypeBLDC Motor
Lighting2 LED Lamps
Voltage240 Volts
Wattage80 Watts
Dimensions (LxWxH)90 x 42 x 47.5 Centimetres
Item Weight12.5 Kilograms
MaterialGlass, Metal

9. Warranty and Support

Faber provides comprehensive warranty coverage and dedicated customer support for your product.

9.1 Warranty Information

  • Product Warranty: 2 Years Comprehensive Warranty on the product.
  • Motor Warranty: 8 Years Warranty on the BLDC Motor.
  • Warranty is valid from the date of purchase. Please retain your purchase invoice for warranty claims.

9.2 Customer Support

For installation requests, service, or any product-related queries, please contact Faber customer support:

  • Toll-Free Number: 1800-209-3484
  • Please have your model number and purchase details ready when contacting support.

© 2024 Faber. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.