1. Introduction
Thank you for choosing the Antari IP-1600 Outdoor Continuous Duty Fog Effects Machine. This manual provides essential information for the safe and efficient operation, setup, and maintenance of your device. Please read this manual thoroughly before operating the machine and retain it for future reference.
The Antari IP-1600 is designed for outdoor use, offering continuous fog output in various environmental conditions due to its robust construction and durable casing.
2. Safety Information
WARNING: Failure to follow these safety instructions may result in fire, electric shock, injury, or damage to the product or property.
- Always connect the unit to a grounded power outlet.
- Do not operate the machine if the power cord is damaged.
- Ensure the machine is placed on a stable, level surface.
- Use only Antari-approved fog fluid. Using other fluids may damage the machine and void the warranty.
- Do not block the ventilation openings.
- Keep children and unauthorized personnel away from the machine during operation.
- Do not direct fog output directly at people or animals.
- Disconnect from power before cleaning or servicing.
- This product is for professional use.
3. Package Contents
Verify that all items listed below are present and in good condition upon unpacking:
- Antari IP-1600 Fog Effects Machine
- Power Cable
- User Manual (this document)
- (Optional accessories may vary by region or package)
4. Product Overview
The Antari IP-1600 is an outdoor-rated fog machine designed for continuous operation. Its robust design ensures reliable performance in various weather conditions.

Figure 4.1: Antari IP-1600 Outdoor Continuous Duty Fog Effects Machine. This image displays the main unit with its durable grey casing, integrated handle, and fog output nozzle.
Key Features:
- Outdoor-rated (IP-rated for weather resistance)
- Continuous duty operation
- Robust construction for demanding conditions
- High-output fog production
5. Setup
5.1 Unpacking and Placement
- Carefully remove the IP-1600 from its packaging.
- Place the machine on a firm, level surface. Ensure there is adequate ventilation around the unit (at least 20 cm / 8 inches of clear space on all sides).
- Position the machine so that the fog output is directed away from people, animals, and sensitive equipment.
5.2 Filling the Fluid Tank
- Ensure the machine is disconnected from the power supply.
- Locate the fluid tank cap, typically on the top or side of the unit.
- Unscrew the cap and carefully pour Antari-approved fog fluid into the tank. Do not overfill.
- Securely replace the fluid tank cap.
5.3 Power Connection
- Connect the provided power cable to the power inlet on the machine.
- Plug the other end of the power cable into a suitable grounded electrical outlet.
6. Operation
6.1 Initial Warm-up
- After connecting to power, turn on the main power switch (if applicable).
- The machine will begin its warm-up cycle. This typically takes several minutes. An indicator light (if present) will change color or state when the machine is ready for operation.
6.2 Producing Fog
Once the machine is warmed up, you can activate fog output using the integrated controls or an external controller (if connected). Refer to your specific controller's manual for detailed instructions.
- Manual Control: Press and hold the fog button on the unit or remote control to produce fog. Release to stop.
- Continuous Output: The IP-1600 is designed for continuous duty. Once activated, it will produce fog until manually stopped or the fluid tank is empty.
6.3 Shutting Down
- Turn off the main power switch on the machine.
- Disconnect the power cable from the electrical outlet.
- Allow the machine to cool down completely before moving or storing.
7. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your Antari IP-1600.
7.1 Cleaning the Exterior
- Ensure the machine is unplugged and cool.
- Wipe the exterior casing with a soft, damp cloth. Do not use abrasive cleaners or solvents.
7.2 Fluid System Maintenance
To prevent clogging and ensure consistent fog output, it is recommended to run a cleaning solution through the machine periodically, especially if storing for extended periods or switching fluid types. Consult Antari's official guidelines for recommended cleaning procedures and solutions.
7.3 Storage
- Drain any remaining fog fluid from the tank if storing for a long duration.
- Store the machine in a cool, dry place, away from direct sunlight and extreme temperatures.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No power | Power cable disconnected; outlet fault; fuse blown | Check power cable connection; test outlet; replace fuse (if accessible and safe to do so) |
| No fog output after warm-up | Fluid tank empty; pump clogged; heater issue | Refill fluid tank; perform fluid system maintenance; contact service if issue persists |
| Low fog output | Low fluid level; partially clogged nozzle; insufficient warm-up | Check fluid level; perform fluid system maintenance; allow full warm-up time |
| Machine overheating | Blocked ventilation; continuous operation beyond limits (unlikely for continuous duty, but check) | Ensure clear ventilation around the unit; allow to cool down; contact service if persistent |
If troubleshooting steps do not resolve the issue, please contact Antari customer support or an authorized service center.
9. Specifications
| Feature | Detail |
|---|---|
| Model | IP-1600 |
| Brand | Antari |
| Product Dimensions | 18.8 x 10.7 x 14.1 inches |
| Item Weight | 27.8 pounds |
| Duty Cycle | Continuous |
| Environmental Rating | Outdoor (IP-rated) |
| ASIN | B0CXQLXT1R |
10. Warranty and Support
For warranty information, please refer to the warranty card included with your product or visit the official Antari website. Keep your proof of purchase for warranty claims.
For technical support, service, or replacement parts, please contact your local Antari dealer or visit www.antari.com for contact information.