1. Introduction
This manual provides essential instructions for the safe and efficient operation, installation, and maintenance of your VEVOR 10-inch Linear Actuator Kit, Model OK628. Please read this manual thoroughly before using the product to ensure proper function and to prevent damage or injury.
The VEVOR linear actuator is designed for various applications requiring controlled linear motion, such as lifting platforms, motorized doors, adjustable furniture, and automation systems. It offers a robust output force of 1000 N (220 lbs) and a travel speed of 25 mm/s (0.98 in/s).

Image 1.1: Overview of the VEVOR 10-inch Linear Actuator Kit and its included components.
2. Safety Instructions
Important: Failure to follow these safety instructions may result in electric shock, fire, or serious injury.
- Always disconnect power before performing any installation, maintenance, or troubleshooting.
- Ensure the power supply voltage matches the actuator's requirements (AC 100-240V input for the adapter).
- Do not exceed the maximum rated load of 1000 N (220 lbs). Overloading can damage the actuator and pose a safety risk.
- The actuator has an IP44 protection rating, meaning it is resistant to dust and water splashes. However, it is not waterproof. Do not immerse the actuator in water, and prevent water from entering the motor housing, as this can cause motor burnout.
- Keep hands and loose clothing away from moving parts during operation.
- Ensure all mounting hardware is securely fastened before operation.
- Operate the actuator within its specified duty cycle (10%). Continuous operation beyond this limit can lead to overheating and damage.
- If any unusual noise, smell, or smoke is observed, immediately disconnect power and cease operation.

Image 2.1: The actuator features an IP44 protection class, resistant to mild dust and water splashes. Avoid submerging or allowing water to enter the motor.
3. Package Contents
Verify that all items listed below are included in your package:
- 1 x VEVOR Linear Actuator (Model OK628-1000N)
- 1 x Power Adapter (AC 100-240V input)
- 1 x Power Cord
- 1 x Controller with Cable
- 2 x Mounting Brackets
- 2 x Screw Rods
- 2 x R-Type Pins

Image 3.1: The package includes the linear actuator, power adapter, controller, mounting brackets, and fasteners.
4. Specifications
Refer to the table below for detailed technical specifications of the VEVOR 10-inch Linear Actuator Kit (Model OK628-1000N).
| Feature | Specification |
|---|---|
| Item Model Number | OK628-1000N |
| Input Voltage (Adapter) | AC 100-240V, 50/60Hz, 1.5A |
| Output Voltage (Actuator) | AC 29V, 1.8A, 52.2W |
| Maximum Load / Actuation Force | 1000 N (220 lbs) |
| Travel Speed | 25 mm/s (0.98 in/s) |
| Stroke Length | 250 mm (10 inches) |
| Retracted Length | 460 mm (18.11 inches) |
| Extended Length | 710 mm (28.11 inches) |
| Protection Class | IP44 |
| Noise Level | ≤50 dB |
| Rated Current | <3A |
| Main Material | Aluminum Alloy |
| Duty Cycle | 10% |
| Product Dimensions (LxWxH) | 460 x 146 x 80 mm (18.11 x 5.74 x 3.14 inches) |
| Net Weight | 2.69 kg (5.93 lbs) |

Image 4.1: Detailed dimensions and performance parameters for the 10-inch linear actuator.
5. Setup and Installation
Follow these steps to properly install and connect your linear actuator:
- Mounting the Actuator:
- Identify the desired mounting locations for the actuator on your application (e.g., TV lift, sofa, cabinet).
- Attach the two mounting brackets to the actuator's ends using the provided screw rods and R-type pins. Ensure they are securely fastened.
- Mount the actuator to your application using appropriate fasteners (not always included, depending on application) through the mounting brackets. Ensure the mounting surface is strong enough to support the actuator's force and weight.
- Wiring Connection:
- Connect the actuator's cable to the output port of the provided power adapter.
- Connect the controller's cable to the designated port on the power adapter.
- Plug the power cord into the power adapter, then connect the power cord to a standard AC 100-240V electrical outlet.
- Initial Test: After installation and wiring, perform a brief test to ensure the actuator extends and retracts smoothly without obstruction.

Image 5.1: Simple wiring diagram showing connections between the actuator, power adapter, and controller.
6. Operation
The linear actuator is controlled via the included wired controller.
- Extension: Press and hold the 'UP' button on the controller to extend the actuator rod. Release the button to stop motion.
- Retraction: Press and hold the 'DOWN' button on the controller to retract the actuator rod. Release the button to stop motion.
- Duty Cycle: The actuator has a duty cycle of 10%. This means for every 1 minute of continuous operation, it requires 9 minutes of rest. For example, if you operate it for 1 minute, allow it to rest for 9 minutes before operating again. Exceeding the duty cycle can lead to overheating and reduced lifespan.
- Load Capacity: Ensure the load applied to the actuator does not exceed 1000 N (220 lbs).

Image 6.1: Example of the linear actuator installed in a cabinet for automated lifting.
7. Maintenance
Regular maintenance helps ensure the longevity and reliable performance of your linear actuator.
- Cleaning: Periodically clean the exterior of the actuator with a soft, dry cloth. Do not use harsh chemicals or abrasive cleaners.
- Inspection: Regularly inspect the actuator for any signs of wear, damage, or loose connections. Check the mounting points for stability.
- Lubrication: The internal components are pre-lubricated and generally do not require additional lubrication under normal operating conditions. If the actuator is exposed to harsh environments, consult VEVOR support for guidance.
- Environmental Protection: While rated IP44, avoid exposing the actuator to excessive moisture, dust, or extreme temperatures to prolong its life.
8. Troubleshooting
If you encounter issues with your linear actuator, refer to the following table for common problems and solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Actuator does not move | No power supply Loose connections Controller malfunction Overload protection activated | Check if the power adapter is plugged in and receiving power. Verify all cables are securely connected. Test the controller if possible. Reduce the load on the actuator. |
| Actuator moves slowly or with difficulty | Excessive load Obstruction in path Low voltage | Reduce the load to within specifications. Check for any physical obstructions. Ensure the power supply is stable and correct. |
| Unusual noise during operation | Mechanical obstruction Internal component wear Improper mounting | Inspect for obstructions. If noise persists, discontinue use and contact VEVOR support. Verify mounting is secure and aligned. |
| Actuator overheats | Exceeded duty cycle Excessive load Poor ventilation | Allow the actuator to cool down and adhere to the 10% duty cycle. Reduce the load. Ensure adequate airflow around the actuator. |
If the problem persists after attempting these solutions, please contact VEVOR customer support for further assistance.
9. Warranty and Support
VEVOR products are designed for durability and performance. For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or visit the official VEVOR website. When contacting support, please have your product model number (OK628) and purchase details ready.