sinocare Safe-Accu2 Teststreifen 50 mit Lanzetten

sinocare Safe-Accu2 Blood Glucose Test Strips

Instruction Manual

1. Introduction

Welcome to the instruction manual for sinocare Safe-Accu2 Blood Glucose Test Strips. This manual provides essential information on the proper use, storage, and maintenance of your test strips and lancets to ensure accurate and reliable blood glucose measurements. These test strips are designed exclusively for use with the sinocare Safe-Accu2 Blood Glucose Meter.

Please read this manual thoroughly before using the product. For any medical concerns, consult your healthcare professional.

2. Product Overview

The sinocare Safe-Accu2 Blood Glucose Test Strips are an integral part of the sinocare Safe-Accu2 Blood Glucose Monitoring System. Each package contains:

These components are designed for easy and rapid blood glucose measurement, providing results in just 5 seconds with a small blood sample of 0.6 microliters.

sinocare Safe-Accu2 Blood Glucose Test Strips and Sinodraw Soft Twist Lancets packaging

Figure 2.1: Packaging of sinocare Safe-Accu2 Blood Glucose Test Strips and Sinodraw Soft Twist Lancets. The image displays two white and red boxes, one for the test strips and one for the lancets, indicating their contents and compatibility.

sinocare Safe-Accu2 Blood Glucose Test Strips vials

Figure 2.2: Two vials of sinocare Safe-Accu2 Blood Glucose Test Strips. The vials are white with blue labels, showing the product name and quantity, indicating they contain the test strips.

3. Setup

Before performing a blood glucose test, ensure you have the following items ready:

Important Compatibility Note: These test strips are specifically designed for the sinocare Safe-Accu2 meter. They are not compatible with other sinocare meters such as Safe Accu, Safe AQ Angel, or Safe AQ.

Compatibility chart for sinocare Safe-Accu2 meter and other sinocare meters

Figure 3.1: Compatibility illustration showing the sinocare Safe-Accu2 meter as compatible (green checkmark) and other sinocare meters (Safe Accu, Safe AQ Angel, Safe AQ) as not compatible (red X mark) with these test strips.

4. Operating Instructions

Follow these steps to perform a blood glucose test:

  1. Prepare the Meter: Insert a new sinocare Safe-Accu2 test strip into the test strip port of your sinocare Safe-Accu2 meter. The meter will automatically turn on.
  2. Prepare the Lancet Device: Load a new, sterile lancet into your lancing device according to the lancing device's instructions.
  3. Obtain Blood Sample: Clean the chosen finger with an alcohol swab (if desired) and allow it to air dry. Use the lancing device to prick the side of your fingertip to obtain a small drop of blood. A blood sample of 0.6 microliters is required.
  4. Apply Blood to Test Strip: Gently touch the tip of the test strip to the blood drop. The strip will automatically draw the blood into the reaction area. Do not smear the blood.
  5. Read Results: The meter will display your blood glucose result in approximately 5 seconds.
  6. Dispose Safely: Immediately dispose of the used test strip and lancet in a suitable sharps container or according to local regulations. Lancets are for single use only.

5. Maintenance and Storage

Proper maintenance and storage are crucial for the accuracy and longevity of your test strips.

6. Troubleshooting

If you encounter issues during testing, consider the following:

If problems persist, contact sinocare customer support or consult your healthcare professional.

7. Specifications

Brandsinocare
Model NumberSafe-Accu2 Teststreifen 50 mit Lanzetten
ASINB0CWGKY18F
Number of Test Strips50
Number of Lancets50
Blood Sample Volume0.6 microliters
Measurement Time5 seconds
Test Strip Shelf Life24 months (unopened), 6 months (after opening)
Package Dimensions11.4 x 6.2 x 4.1 cm
Package Weight83 grams
ManufacturerChangsha Sinocare Inc.

8. Warranty and Support

For specific warranty information regarding your sinocare Safe-Accu2 Blood Glucose Test Strips, please refer to the warranty card included with your purchase or contact the retailer or manufacturer directly. Warranty terms may vary by region and seller.

For technical support, product inquiries, or to report any issues, please contact sinocare customer service through their official website or the contact information provided on the product packaging. Always have your product model number and purchase details ready when contacting support.

Related Documents - Safe-Accu2 Teststreifen 50 mit Lanzetten

Preview Sinocare Safe AQ Pro Series Blood Glucose Monitoring System User Manual
This user manual provides comprehensive instructions for the Sinocare Safe AQ Pro Series Blood Glucose Monitoring System, covering setup, operation, maintenance, troubleshooting, and important safety information for accurate blood glucose level monitoring.
Preview Sinocare Safe AQ Pro Series Blood Glucose Monitoring System User Manual
Comprehensive user manual for the Sinocare Safe AQ Pro Series blood glucose monitoring system, covering setup, operation, safety guidelines, troubleshooting, and specifications for accurate diabetes management.
Preview Sinocare Safe-Accu 2 Blood Glucose Test Strips: User Guide and Specifications
Comprehensive package insert for Sinocare Safe-Accu 2 Blood Glucose Test Strips, covering intended use, test principles, performance, and important warnings for self-testing.
Preview Safe AQ Smart, Safe AQ Voice, Safe AQ Air Blood Glucose Meter User Manual
Comprehensive user manual for the Sinocare Safe AQ Smart, Safe AQ Voice, and Safe AQ Air blood glucose monitoring systems. Learn about intended use, safety information, test principles, operation, troubleshooting, and maintenance.
Preview Sinocare Safe AQ Voice Quick Guide: Easy Blood Glucose Monitoring
A concise guide to using the Sinocare Safe AQ Voice blood glucose meter for quick and accurate blood sugar testing. Learn how to prepare materials, perform the test, and interpret results.
Preview Sinocare Safe AQ UG Blood Glucose Test Strips User Manual
User manual for Sinocare Safe AQ UG Blood Glucose Test Strips, detailing intended use, compatibility with the Safe AQ UG monitor, storage, handling, and testing procedures for accurate blood glucose monitoring.