1. Introduction
Welcome to the instruction manual for sinocare Safe-Accu2 Blood Glucose Test Strips. This manual provides essential information on the proper use, storage, and maintenance of your test strips and lancets to ensure accurate and reliable blood glucose measurements. These test strips are designed exclusively for use with the sinocare Safe-Accu2 Blood Glucose Meter.
Please read this manual thoroughly before using the product. For any medical concerns, consult your healthcare professional.
2. Product Overview
The sinocare Safe-Accu2 Blood Glucose Test Strips are an integral part of the sinocare Safe-Accu2 Blood Glucose Monitoring System. Each package contains:
- 50 Safe-Accu2 Test Strips
- 50 Blood Collection Lancets
These components are designed for easy and rapid blood glucose measurement, providing results in just 5 seconds with a small blood sample of 0.6 microliters.

Figure 2.1: Packaging of sinocare Safe-Accu2 Blood Glucose Test Strips and Sinodraw Soft Twist Lancets. The image displays two white and red boxes, one for the test strips and one for the lancets, indicating their contents and compatibility.

Figure 2.2: Two vials of sinocare Safe-Accu2 Blood Glucose Test Strips. The vials are white with blue labels, showing the product name and quantity, indicating they contain the test strips.
3. Setup
Before performing a blood glucose test, ensure you have the following items ready:
- sinocare Safe-Accu2 Blood Glucose Meter (not included with this product)
- sinocare Safe-Accu2 Test Strip
- sinocare Blood Collection Lancet
- Alcohol swab (optional, for cleaning the finger)
Important Compatibility Note: These test strips are specifically designed for the sinocare Safe-Accu2 meter. They are not compatible with other sinocare meters such as Safe Accu, Safe AQ Angel, or Safe AQ.

Figure 3.1: Compatibility illustration showing the sinocare Safe-Accu2 meter as compatible (green checkmark) and other sinocare meters (Safe Accu, Safe AQ Angel, Safe AQ) as not compatible (red X mark) with these test strips.
4. Operating Instructions
Follow these steps to perform a blood glucose test:
- Prepare the Meter: Insert a new sinocare Safe-Accu2 test strip into the test strip port of your sinocare Safe-Accu2 meter. The meter will automatically turn on.
- Prepare the Lancet Device: Load a new, sterile lancet into your lancing device according to the lancing device's instructions.
- Obtain Blood Sample: Clean the chosen finger with an alcohol swab (if desired) and allow it to air dry. Use the lancing device to prick the side of your fingertip to obtain a small drop of blood. A blood sample of 0.6 microliters is required.
- Apply Blood to Test Strip: Gently touch the tip of the test strip to the blood drop. The strip will automatically draw the blood into the reaction area. Do not smear the blood.
- Read Results: The meter will display your blood glucose result in approximately 5 seconds.
- Dispose Safely: Immediately dispose of the used test strip and lancet in a suitable sharps container or according to local regulations. Lancets are for single use only.
5. Maintenance and Storage
Proper maintenance and storage are crucial for the accuracy and longevity of your test strips.
- Test Strip Storage: Store test strips in their original vial with the cap tightly closed. Keep them in a cool, dry place away from direct sunlight and heat. Do not refrigerate.
- Shelf Life: The test strips have a shelf life of 24 months from the manufacturing date. Once the vial is opened, the test strips are stable for 6 months. Always note the opening date on the vial.
- Disposal: Dispose of used test strips and lancets responsibly. Follow local guidelines for the disposal of medical waste. Never reuse lancets or test strips.
- Meter Care: While this manual focuses on test strips, ensure your sinocare Safe-Accu2 meter is kept clean and dry. Refer to your meter's instruction manual for specific cleaning guidelines.
6. Troubleshooting
If you encounter issues during testing, consider the following:
- Error Message on Meter: Refer to your sinocare Safe-Accu2 meter's instruction manual for specific error codes and their solutions.
- Inaccurate Results:
- Ensure the test strip vial cap was tightly closed after the last use.
- Check the expiry date on the test strip vial.
- Verify that the blood sample size is sufficient (0.6 µL).
- Ensure your hands are clean and dry before testing.
- Perform a control solution test if available, to check meter and strip accuracy.
- No Blood Sample Drawn: Ensure the test strip is correctly inserted into the meter and that the blood drop is large enough and properly touched to the strip's absorbent tip.
If problems persist, contact sinocare customer support or consult your healthcare professional.
7. Specifications
| Brand | sinocare |
| Model Number | Safe-Accu2 Teststreifen 50 mit Lanzetten |
| ASIN | B0CWGKY18F |
| Number of Test Strips | 50 |
| Number of Lancets | 50 |
| Blood Sample Volume | 0.6 microliters |
| Measurement Time | 5 seconds |
| Test Strip Shelf Life | 24 months (unopened), 6 months (after opening) |
| Package Dimensions | 11.4 x 6.2 x 4.1 cm |
| Package Weight | 83 grams |
| Manufacturer | Changsha Sinocare Inc. |
8. Warranty and Support
For specific warranty information regarding your sinocare Safe-Accu2 Blood Glucose Test Strips, please refer to the warranty card included with your purchase or contact the retailer or manufacturer directly. Warranty terms may vary by region and seller.
For technical support, product inquiries, or to report any issues, please contact sinocare customer service through their official website or the contact information provided on the product packaging. Always have your product model number and purchase details ready when contacting support.