1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your NCLTHS Access Control System. This kit is designed to provide secure and convenient access management for various indoor applications. Please read this manual thoroughly before installation and operation to ensure proper functioning and safety.

2. Safety Information

  • Electrical Safety: The power supply unit contains hazardous voltage. Do not open the power supply cover. All wiring should be performed by qualified personnel to prevent electric shock or damage to the system.
  • Installation: Ensure all components are securely mounted. Improper installation of the magnetic lock or strike plate can compromise security and system performance.
  • Power Source: Use only the provided 110-240VAC to 12VDC power supply. Connecting to an incorrect power source may damage the unit.
  • Environment: This system is recommended for indoor use. Avoid exposure to moisture, extreme temperatures, or corrosive environments.
  • Emergency Access: Always ensure there is an alternative method for emergency exit in case of power failure or system malfunction.

3. Package Contents

Verify that all items listed below are included in your package:

  • 1 x 600LBS Electric Magnetic Lock
  • 1 x Access Control Keypad
  • 1 x Doorbell Chime
  • 2 x Remote Transmitters
  • 1 x Remote Receiver
  • 5 x RFID Keyfobs
  • 1 x English User Manual (this document)
  • 1 x Power Supply Control Unit
  • 1 x Push to Exit Button
Image showing all components included in the NCLTHS Access Control System kit

Figure 3.1: All included components of the NCLTHS Access Control System kit.

4. Setup and Installation

Careful installation is crucial for the proper functioning and security of your access control system. Ensure all connections are secure and correct before applying power.

4.1 Component Overview

Access Control Keypad

Access Control Keypad

600lbs Magnetic Lock

600lbs Magnetic Lock

Doorbell Chime

Doorbell Chime

Push to Exit Button

Push to Exit Button

Remote Receiver

Remote Receiver

Remote Transmitter

Remote Transmitter

Power Supply Control Unit

Power Supply Control Unit

4.2 Wiring Diagram

Refer to the following wiring diagrams for connecting the components. Ensure all wires are correctly identified and connected to the appropriate terminals on the power supply, keypad, and other devices.

Detailed wiring diagram for the NCLTHS Access Control System, showing connections between magnetic lock, keypad, power supply, exit button, and remote receiver.

Figure 4.2.1: Comprehensive Wiring Diagram for the Access Control System.

Simplified wiring diagram showing the connection of the magnetic lock, power supply, keypad, and exit button.

Figure 4.2.2: Simplified Wiring Overview.

4.3 Installation Steps

  1. Mount the Magnetic Lock: Install the electromagnetic lock on the door frame and the armature plate on the door. Ensure proper alignment for secure locking. Mounting brackets (not included) may be required depending on your door type and frame.
  2. Mount the Access Control Keypad: Secure the keypad near the entry point, typically on the outside of the door.
  3. Mount the Exit Button: Install the push-to-exit button on the inside of the door, allowing for easy egress.
  4. Install the Power Supply Control Unit: Mount the power supply unit in a secure, accessible location, ensuring it is protected from environmental factors.
  5. Connect Wiring: Follow the wiring diagrams carefully. Connect the magnetic lock, keypad, exit button, doorbell, and remote receiver to the power supply control unit. Pay close attention to positive (+12V), negative (GND), Normally Open (NO), and Normally Closed (NC) connections.
  6. Connect Power: Once all components are wired, connect the power supply unit to a 110-240VAC power source.
  7. Test System: After installation, test all functions: keypad entry, RFID card entry, remote control operation, and exit button release.

Video 4.3.1: Detailed installation and wiring guide for the Access Control System. This video demonstrates the connection process for various components.

5. Operating Instructions

5.1 Keypad Operation

The keypad allows access via a numerical code or RFID card/keyfob.

  • Default Access Code: The default access code is typically 1234.
  • Entering an Access Code: Enter your 4-digit code followed by the '#' key. The door will unlock for a preset duration.
  • Adding User Codes:
    1. Enter Programming Mode: Press '*' then enter the Master Code (default: 123456) then '#'.
    2. Add User Code: Press '1' then enter a 3-digit User ID (e.g., 001) then '#'. Enter the new 4-digit User Code then '#'. Repeat for additional users.
    3. Exit Programming Mode: Press '*' to save and exit.
  • Adding RFID Cards/Keyfobs:
    1. Enter Programming Mode: Press '*' then enter the Master Code (default: 123456) then '#'.
    2. Add Card: Press '1' then present the RFID card/keyfob to the keypad. The keypad will beep to confirm. Repeat for additional cards.
    3. Exit Programming Mode: Press '*' to save and exit.
  • Deleting User Codes/Cards: Consult the specific keypad manual for detailed instructions on deleting individual users or resetting the keypad.
RFID Keyfobs and cards used for access control

Figure 5.1.1: RFID Keyfobs and Cards.

5.2 Remote Control Operation

The remote transmitters allow convenient unlocking from a distance.

  • Pairing Remotes: The remotes are typically pre-paired with the receiver. If re-pairing is needed, refer to the remote receiver's specific instructions. Usually, this involves pressing a learning button on the receiver and then a button on the remote.
  • Unlocking: Press the unlock button on the remote transmitter. The door will momentarily unlock.

5.3 Exit Button Operation

The push-to-exit button provides a simple way to exit from the secured area.

  • Exiting: Press the exit button. The magnetic lock will disengage, allowing the door to open.

6. Maintenance

Regular maintenance ensures the longevity and reliable performance of your access control system.

  • Cleaning: Clean the keypad and magnetic lock surfaces with a soft, dry cloth. Avoid abrasive cleaners or solvents.
  • Check Connections: Periodically inspect all wiring connections to ensure they are secure and free from corrosion.
  • Magnetic Lock Alignment: Ensure the magnetic lock and armature plate remain properly aligned. Misalignment can reduce holding force.
  • Battery Replacement (Remotes): If remote controls become unresponsive, replace their internal batteries.

7. Troubleshooting

If you encounter issues with your access control system, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Magnetic lock does not engage or holds weakly.Incorrect wiring; insufficient power; misalignment of lock and armature plate; improper mounting.Verify all wiring connections (refer to Section 4.2). Ensure the power supply is providing stable 12VDC. Check alignment and adjust if necessary. Confirm the magnetic lock and armature plate are securely mounted, potentially requiring appropriate brackets for your door type.
Keypad is unresponsive or not powering on.No power to keypad; faulty wiring; keypad malfunction.Check power connections to the keypad from the power supply. Ensure the power supply unit is receiving input power. Verify wiring integrity.
Cannot add more than 4 users to the keypad.Keypad user capacity limit reached; incorrect programming steps.Some keypads have a limited number of user slots. Consult the specific keypad's detailed manual for its maximum user capacity and advanced programming options. Ensure you are following the correct sequence for adding users (Section 5.1).
Remote control does not unlock the door.Remote battery low/dead; remote not paired; remote receiver issue.Replace the battery in the remote transmitter. Re-pair the remote with the receiver (refer to Section 5.2). Check wiring to the remote receiver.
Exit button does not release the lock.Incorrect wiring; faulty button.Verify wiring connections for the exit button to the power supply control unit. Test the button for continuity if possible.

8. Specifications

FeatureDetail
BrandNCLTHS
Model NameAccess Control System
Model NumberElectric Magnetic Door Lock Kit
Lock TypeCombination Lock (Magnetic)
Holding Force600 LBS (280 Kg)
MaterialAluminum
Power Supply Input110-240VAC, 50Hz
Power Supply Output12VDC, 4A
Recommended UseIndoor
Special FeatureAuto-Lock
Control MethodTouch (Keypad), Hand Control (Remote, Exit Button)
Connectivity ProtocolZ-Wave (Note: This may refer to the keypad's internal capability, not necessarily an included Z-Wave hub)
Item Dimensions (L x W x H)12 x 8 x 3.5 inches (Overall kit packaging)
GTIN716841008746
ASINB0CW9NRSTP

9. Warranty and Support

For warranty information, please refer to the terms and conditions provided at the time of purchase or contact your retailer. If you require technical assistance or have questions not covered in this manual, please contact the manufacturer or seller directly. Keep your purchase receipt as proof of purchase for any warranty claims.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.