1. Product Overview

The Goodman Mini-Split AC/Heating System E-Series is a highly efficient ductless solution designed for comfortable climate control in various spaces. This system provides both cooling and heating functionalities, featuring inverter technology for energy savings and quiet operation.

Goodman Mini-Split AC/Heating System E-Series with installation kit

Image: The Goodman Mini-Split AC/Heating System E-Series, showing both the indoor air handler unit and the outdoor condenser unit, along with the complete ACiQ Mini Split Installation Kit.

Key Features:

  • BTU Capacity: 0.75-ton system, efficiently heats (4,400 BTU – 13,000 BTU) and cools (4,400 BTU - 10,200 BTU).
  • SEER2 Efficiency: Impressive 18 SEER2 rating with Inverter Technology for energy savings.
  • Coverage Area: Easily covers small to medium rooms (up to 400 sq ft) in ideal climates.
  • Quiet Operation: Designed for low noise levels.
  • Comprehensive Installation Kit: Includes all necessary components for setup.
Goodman E-Series Features Diagram

Image: Diagram illustrating key features of the E-Series, including Auto-Restart, Wireless Backlight Remote Control, Self-Diagnosis with Digital Display, Adjustable LED Display, Outdoor Anti-corrosion Treatment, Power Saving Sleep Mode, Removable Dirt-Water Drain Pan, Indoor Unit ON/OFF Switch, Catechin Air Quality Filter System, Titanium Apatite Deodorising Filter, and Wipe-Clean Flat Panel.

2. Setup and Installation

Proper installation is crucial for the optimal performance and longevity of your mini-split system. It is highly recommended that installation be performed by a qualified HVAC technician.

2.1. Installation Kit Contents:

The Goodman Mini-Split AC/Heating System comes with a comprehensive installation kit to facilitate setup.

ACiQ Mini Split Installation Kit Components

Image: Components of the ACiQ Mini Split Installation Kit, including the indoor wall-mounted air handler unit, outdoor mini split heat pump condenser, line set (15-ft length, 1/4 x 3/8 copper lines) and control wire, wall mount bracket (18 1/4" length), line cover guards with 20-ft drain tube, and remote control.

  • Indoor Wall Mounted Air Handler Unit
  • Outdoor Mini Split Heat Pump Condenser
  • Line Set (15-ft length, 1/4 x 3/8 copper lines) and Control Wire
  • Wall Mount Bracket (18 1/4" Length)
  • Line Cover Guards with 20-ft Drain Tube
  • Remote Control

2.2. Pre-Installation Checklist:

  1. Verify the correct BTU capacity for your room size (up to 400 sq ft for this 9,000 BTU model).
  2. Ensure the electrical supply matches the unit's requirements (208/230v 1Phase 60Hz).
  3. Select an appropriate location for both indoor and outdoor units, ensuring proper airflow and drainage.
  4. Confirm all components listed in the installation kit are present and undamaged.

2.3. General Installation Steps (Professional Installation Recommended):

  1. Mount the indoor unit securely on the wall, ensuring it is level.
  2. Install the outdoor condenser unit on a stable, level surface or wall mount bracket.
  3. Connect the refrigerant line set and electrical control wire between the indoor and outdoor units. Ensure proper flaring and torque.
  4. Connect the drain tube from the indoor unit to an appropriate drainage point.
  5. Perform vacuuming of the refrigerant lines to remove air and moisture.
  6. Open the refrigerant valves and check for leaks.
  7. Connect the power supply to the outdoor unit.
  8. Test the system's operation in both cooling and heating modes.

3. Operating Instructions

Your Goodman Mini-Split system is designed for user-friendly operation via the included wireless remote control.

3.1. Remote Control Functions:

  • Power Button: Turns the unit ON/OFF.
  • Mode Selection: Cycle through Cooling, Heating, Fan, and Dry modes.
  • Temperature Adjustment: Use UP/DOWN arrows to set desired temperature.
  • Fan Speed: Adjust fan speed (Auto, Low, Medium, High).
  • Sleep Mode: Activates power-saving sleep mode for quiet operation and optimized temperature during sleep.
  • Timer Function: Set the unit to turn ON or OFF automatically at specific times.
  • Swing Function: Controls the louver direction for optimal air distribution.
  • LED Display ON/OFF: Option to turn off the indoor unit's LED display for undisturbed sleep.

3.2. Operating Modes:

  • Cooling Mode: For cooling the room. Set desired temperature.
  • Heating Mode: For heating the room. Set desired temperature.
  • Fan Mode: Circulates air without cooling or heating.
  • Dry Mode (Dehumidification): Reduces humidity in the room.

3.3. Special Features:

  • Auto-Restart After Power Failure: The unit will automatically resume operation with previous settings after a power outage.
  • Self-Diagnosis with Digital Display: The unit can display error codes on its digital display to assist in troubleshooting.
  • Outdoor Anti-corrosion Treatment: Enhances the durability and lifespan of the outdoor unit.

4. Maintenance

Regular maintenance ensures the efficiency and longevity of your Goodman Mini-Split system.

4.1. Air Filter Cleaning:

  • The indoor unit is equipped with a Catechin Air Quality Filter System and a Titanium Apatite Deodorising Filter.
  • Clean the air filters every 2-4 weeks, or more frequently depending on usage and air quality.
  • Open the front panel of the indoor unit and remove the filters.
  • Wash filters with lukewarm water and mild detergent, or vacuum them to remove dust.
  • Allow filters to dry completely before reinserting them.

4.2. Indoor Unit Cleaning:

  • The indoor unit features a Wipe-Clean Flat Panel for easy exterior cleaning.
  • Wipe the exterior of the indoor unit with a soft, damp cloth. Do not use harsh chemicals or abrasive cleaners.
  • The unit has a Removable Dirt-Water Drain Pan. Consult a technician for periodic cleaning of the drain pan and coil to prevent mold and mildew buildup.

4.3. Outdoor Unit Maintenance:

  • Ensure the outdoor unit's coils are free from debris, leaves, and dirt. Gently clean with a soft brush or water hose.
  • Keep the area around the outdoor unit clear to ensure proper airflow.
  • Schedule annual professional maintenance to check refrigerant levels, electrical connections, and overall system health.

5. Troubleshooting

This section provides solutions to common issues you might encounter. For complex problems, contact a certified technician.

ProblemPossible CauseSolution
Unit does not turn on.No power supply; Remote control batteries dead; Circuit breaker tripped.Check power connection; Replace remote batteries; Reset circuit breaker.
Insufficient cooling/heating.Dirty air filters; Blocked outdoor unit; Incorrect mode setting; Room size too large.Clean filters; Clear obstructions around outdoor unit; Select correct mode; Ensure unit matches room size.
Unusual noise.Loose parts; Fan obstruction; Refrigerant flow noise (normal).Check for loose parts; Remove obstructions; If noise persists, contact technician.
Water leakage from indoor unit.Clogged drain pipe; Improper installation.Clear drain pipe; Contact technician for inspection.
Digital display shows error code.System malfunction (Self-Diagnosis feature).Note the error code and consult the full service manual or contact a certified technician.

6. Specifications

Detailed technical specifications for the Goodman Mini-Split AC/Heating System E-Series (0.75 Ton, 9000 BTU).

Goodman Mini-Split Dimensions and Specifications

Image: Visual representation of the indoor and outdoor unit dimensions, along with a table detailing BTU to square feet coverage, Tons to Decibels (dBA) noise levels, and Electrical Specifications (208/230V 1 Phase 60Hz).

SpecificationValue
Brand NameACiQ
Model InfoGoodman E-Series
Item Model NumberRXNG09AXVJU / FTXNG09AXVJU / GM1ZE15S
Efficiency18 SEER2
Noise Level56 dB
Installation TypeSplit System
Form FactorMini-Split
Special FeaturesCooling, Heating, Inverter Technology, Auto-Restart, Self-Diagnosis
Voltage230 Volts (208/230v 1Phase 60Hz)
Material Type9,000 BTU | 0.75 Tons
Floor Area CoverageUp to 400 Square Feet
Cooling Power9000 British Thermal Units
RefrigerantR 410A
Power SourceCorded Electric

7. Warranty and Support

7.1. Warranty Conditions:

This Goodman Mini-Split AC/Heating System includes a 5-year parts warranty. This warranty is valid when the unit is installed by a certified technician and registered online with the manufacturer. Please retain your proof of purchase and installation records.

7.2. Customer Support:

For technical assistance, warranty claims, or service inquiries, please contact the manufacturer's customer support. Refer to the product packaging or manufacturer's website for the most current contact information.

Note: No official product videos were available for embedding based on the provided data.

© 2024 ACiQ. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.