Rigol DG902 Pro

RIGOL DG902 Pro Waveform Generator User Manual

Model: DG902 Pro

Brand: Rigol

1. Product Overview

The RIGOL DG902 Pro is a high-performance waveform generator designed for a wide range of applications requiring precise signal generation. It features a 16-bit vertical resolution, a maximum sample rate of 1.25 GSa/s, and a 70 MHz output frequency. This device is capable of generating various waveforms and offers advanced modulation capabilities.

Key features include:

Front view of the RIGOL DG902 Pro Waveform Generator

Figure 1.1: Front view of the RIGOL DG902 Pro Waveform Generator, showing the display, control panel, and output channels.

2. Setup and Connections

2.1 Unpacking and Inspection

Carefully unpack the DG902 Pro waveform generator and all accessories from the shipping carton. Inspect the instrument for any signs of damage that may have occurred during transit. If any damage is found, contact your supplier immediately.

2.2 Power Connection

Connect the provided power adapter to the DC input port on the rear panel of the instrument. Plug the power adapter into a suitable AC power outlet. The DG902 Pro can also be operated via a USB-C power bank for portable use.

RIGOL DG902 Pro connected to a USB-C power bank

Figure 2.1: The DG902 Pro connected to an external USB-C power bank, demonstrating its portable power capability.

2.3 Input/Output Connections

The rear panel of the DG902 Pro provides various input and output ports for signal generation and external synchronization.

Rear view of the RIGOL DG902 Pro Waveform Generator showing connection ports

Figure 2.2: Rear view of the DG902 Pro, highlighting the 10MHz REF IN/OUT, AUX IN/OUT, LAN, USB DEVICE, and USB-C ports.

  • Channel Outputs (CH1, CH2): Located on the front panel, these BNC connectors provide the main waveform outputs.
  • 10MHz REF IN/OUT: Used for external reference clock synchronization.
  • AUX IN/OUT: Auxiliary input/output ports for additional signal routing.
  • LAN Port: For network connectivity and remote control.
  • USB DEVICE Port: For connecting to a computer for data transfer and control.

3. Operating Instructions

3.1 User Interface and Display

The DG902 Pro features a 7.0-inch color display with a resolution of 1024x600 pixels, providing a clear and intuitive interface for operation. Navigation is primarily done through the rotary knob, directional buttons, and dedicated function keys.

Close-up of the RIGOL DG902 Pro's 7.0-inch display

Figure 3.1: A close-up view of the DG902 Pro's 7.0-inch display, highlighting its size and resolution.

RIGOL DG902 Pro screen showing channel 1 and channel 2 settings

Figure 3.2: The DG902 Pro display showing detailed settings for Channel 1 and Channel 2, including frequency, amplitude, and offset.

3.2 Basic Waveform Generation

  1. Power On: Press the power button located on the front panel to turn on the instrument.
  2. Select Channel: Use the CH1 or CH2 buttons to select the desired output channel.
  3. Select Waveform Type: Press the Waveform button (e.g., Sine, Square, Pulse, Ramp, Arb, Noise) to choose the desired waveform.
  4. Set Parameters: Use the rotary knob and numeric keypad to adjust parameters such as frequency, amplitude, and offset. The display will show the current settings.
  5. Enable Output: Press the On/Off button for the selected channel to enable the waveform output.

3.3 Advanced Modulation Functions

The DG902 Pro supports various modulation types to meet complex signal generation requirements. These include Amplitude Modulation (AM), Frequency Modulation (FM), Phase Modulation (PM), Amplitude Shift Keying (ASK), Frequency Shift Keying (FSK), Pulse Width Modulation (PWM), and Sum modulation.

RIGOL DG902 Pro with various modulation types illustrated around it

Figure 3.3: An illustration showing the DG902 Pro's support for various modulation types, including AM, FM, PM, ASK, FSK, PWM, and SUM.

To access modulation settings, press the Mod button and navigate through the options using the display and control knob.

4. Maintenance

4.1 Cleaning the Instrument

To maintain the performance and appearance of your DG902 Pro, regularly clean its exterior. Use a soft, damp cloth with a mild detergent to wipe down the casing. Avoid using abrasive cleaners or solvents that could damage the plastic components or screen.

  • Always disconnect the power before cleaning.
  • Do not allow any liquids to enter the instrument.
  • Clean the display screen gently with a soft, lint-free cloth.

4.2 Storage

When not in use for extended periods, store the DG902 Pro in a dry, dust-free environment, away from direct sunlight and extreme temperatures. It is recommended to store the instrument in its original packaging or a protective case to prevent damage.

5. Troubleshooting

This section provides solutions to common issues you might encounter with your DG902 Pro Waveform Generator. If the problem persists after trying these steps, please contact Rigol customer support.

ProblemPossible CauseSolution
Instrument does not power on.Power cable not connected properly; power outlet issue; power adapter fault.Check power cable connection. Try a different power outlet. Ensure power adapter is functioning correctly.
No waveform output.Output channel not enabled; amplitude set to zero; incorrect cable connection.Press the On/Off button for the channel. Increase amplitude. Verify BNC cable connections.
Display is blank or frozen.Software error; temporary glitch.Restart the instrument by powering it off and on again. If the issue persists, contact support.

6. Specifications

The following table outlines the key technical specifications of the RIGOL DG902 Pro Waveform Generator.

ParameterValue
Model NumberDG902 Pro
Max. Sample Rate1.25 GSa/s
Output FrequencyUp to 70 MHz
Channels2
Vertical Resolution16 Bit
Arb Length16 Mpts/CH (32 Mpts/CH optional)
Rise TimeAs low as 3 ns
Waveform JitterAs low as 200 ps
Counter Bandwidth1 GHz
Product Dimensions10.47 x 6.5 x 3.15 inches
Weight3.92 Pounds
ManufacturerRIGOL

7. Warranty and Support

7.1 Warranty Information

RIGOL provides a standard warranty for its products, covering defects in materials and workmanship under normal use. For specific warranty terms and duration, please refer to the warranty card included with your product or visit the official RIGOL website. Keep your purchase receipt as proof of purchase for warranty claims.

7.2 Customer Support

For technical assistance, troubleshooting, or service requests, please contact RIGOL customer support. You can find contact information, including phone numbers and email addresses, on the official RIGOL website (www.rigol.com). When contacting support, please have your product model number (DG902 Pro) and serial number ready.

Related Documents - DG902 Pro

Preview RIGOL DG800 Pro/DG900 Pro Series Programming Guide
This programming guide provides detailed information on using SCPI commands to control RIGOL DG800 Pro and DG900 Pro series function/arbitrary waveform generators via remote interfaces like USB and LAN.
Preview RIGOL DG800 Pro Series Function/Arbitrary Waveform Generator Quick Guide
A quick guide to the RIGOL DG800 Pro Series Function/Arbitrary Waveform Generator, covering safety requirements, product overview, preparation, operation, remote control, and troubleshooting.
Preview RIGOL DG5000 Pro Series Function/Arbitrary Waveform Generator User Guide
Comprehensive user guide for the RIGOL DG5000 Pro Series Function/Arbitrary Waveform Generator. This manual details product features, safety instructions, quick start operations, and advanced functions like modulation, sweep, burst, and pattern generation. It covers models such as DG5508 Pro, DG5252 Pro, and others, providing essential information for effective use and setup.
Preview RIGOL DG5000 Pro Series Function/Arbitrary Waveform Generator Quick Guide
This quick guide provides essential information for the RIGOL DG5000 Pro Series Function/Arbitrary Waveform Generator, covering safety requirements, product overview, preparation for use, operation, and troubleshooting.
Preview DG5000 Pro Series Function/Arbitrary Waveform Generator Performance Verification
This document provides detailed procedures for performance verification of the RIGOL DG5000 Pro Series Function/Arbitrary Waveform Generator, covering frequency accuracy, amplitude accuracy, DC offset accuracy, AC flatness, harmonic distortion, spurious signals, and overshoot tests.
Preview Руководство пользователя RIGOL DS1000Z Цифровой осциллограф
Подробное руководство пользователя для цифровых осциллографов RIGOL серии DS1000Z, включая модели DS1054Z, DS1104Z, DS1074Z и другие. Охватывает характеристики, безопасность, эксплуатацию и технические детали.