WANLUTECH MOT-51

Download PDF
Contents

WANLUTECH MOT-51 OTDR Fiber Tester User Manual

Model: MOT-51

1. Introduction

The WANLUTECH MOT-51 is a versatile Optical Time Domain Reflectometer (OTDR) designed for comprehensive fiber optic and network cable testing. This device integrates multiple functions including OTDR, Optical Power Meter (OPM), Visual Fault Locator (VFL), Light Source (LS), Optical Loss Test (OLT), Event Map, RJ45 Cable Tester, and various network tools. It features a 5.55-inch touchscreen for intuitive operation and data visualization.

2. Safety Information

  • Laser Safety: The VFL and Light Source functions emit laser radiation. Avoid direct eye exposure to the laser beam. Never look directly into the optical output ports when the device is active.
  • Battery Safety: Use only the specified battery and charging cable. Do not disassemble, puncture, or expose the battery to extreme temperatures or fire.
  • Environmental Conditions: Operate the device within the specified temperature and humidity ranges. Avoid exposure to water, dust, and corrosive substances.
  • Maintenance: Refer to the maintenance section for cleaning and care instructions. Do not attempt to service the device yourself. Contact support for assistance.

3. Package Contents

Verify that all items listed below are included in your package:

  • WANLUTECH MOT-51 OTDR Fiber Tester
  • Tool Bag
  • Li-ion Battery (pre-installed)
  • FC/UPC-UPC/APC Patch Cord
  • SC/UPC Adapter
  • FC/UPC Adapter
  • ST/UPC Adapter
  • LC/UPC Adapter
  • FC male-FC female adapter
  • FC male-SC female adapter
  • FC(male)-LC(female) adapter
  • SC/UPC(Male)-SC/APC(Female) adapter
  • Charging Cable (Note: Charging adapter not included)
  • OTDR Test Report
  • Cable Tester Remote Kit
WANLUTECH MOT-51 OTDR Fiber Tester and included accessories

Image 3.1: WANLUTECH MOT-51 OTDR Fiber Tester with all included accessories.

4. Product Overview

Familiarize yourself with the physical components and interfaces of the MOT-51 tester.

Top and bottom views of the WANLUTECH MOT-51 OTDR Fiber Tester showing ports and interfaces

Image 4.1: Top and bottom views of the MOT-51, highlighting network testing port/RJ45 TDR, VFL, OPM, OTDR/LS interface, flashing light, SD card slot, Type-C DC5V/2A IN, and DC5V/1A OUT/USB ports.

5. Setup

Before initial use, perform the following steps:

  1. Battery Activation: The device ships with a protective paper piece isolating the battery. Open the battery cover and remove this paper piece to enable battery contact.
  2. Charging: Connect the device to a power source using the provided charging cable. The charging adapter is not included.
Instruction to remove battery isolation paper before use

Image 5.1: Important reminder to remove the battery isolation paper before using the tester.

6. Operating Instructions

6.1. OTDR (Optical Time Domain Reflectometer) Test

The OTDR function is used to characterize optical fibers. It operates at wavelengths 1310nm/1550nm with a dynamic range of 26dB/24dB. This model cannot test live fiber.

Quick Setup Mode:

Allows for rapid configuration of wavelength, distance range, pulse width, and measurement duration for quick tests.

Parameters Set Mode:

For professional users, this mode enables detailed adjustment of wavelength, distance range, pulse width, measurement mode, IOR (Index of Refraction), non-reflection threshold, end threshold, and other parameters to achieve more precise curve results.

Screenshots showing OTDR Quick Setup mode, Parameters Set mode, and Event Map display

Image 6.1.1: OTDR Quick Setup and Parameters Set interfaces.

Event Map & Data Storage:

Visualize fiber optic link inspection results. Information such as fiber length, connector type, fusion points, or breakpoints are presented graphically. Test curves can be saved, zoomed, and moved for detailed analysis. Event Blind Zone is less than 1.6m, and Attenuation Blind Zone is less than 8m. The device supports creating test reports in PDF/EXCEL format, including curve trajectory graphs, parameter settings, fiber event information, and fiber link details.

  • Initial Event: The starting point of the link.
  • Reflection Event: Connector or reflection event shown as a peak.
  • Non-reflection Event: Fusion point or optical fiber bending, shown as a drop in optical power.
  • End Event: The terminal of the fiber, a normal end with a reflection peak.
  • End Event (Optical Fiber Bending): An end with non-reflection peak indicates a fracture.
Event Map display and Threshold Setting for OTDR

Image 6.1.2: Event Map visualization and threshold settings.

6.2. OPM (Optical Power Meter)

The OPM measures optical power linearly or non-linearly for direct display or relative measurement of fiber link loss. Calibrated wavelengths include 850/1300/1310/1490/1550/1625nm.

Screenshots of Optical Loss Test, Visual Fault Locator, Light Source, and Optical Power Meter functions

Image 6.2.1: OPM interface showing power measurement.

6.3. VFL (Visual Fault Locator)

The VFL is used to determine fiber continuity and locate faults. It operates at a 650nm wavelength with a maximum test range of 8 KM.

Visual Fault Locator interface with warning about laser light

Image 6.3.1: VFL interface, displaying laser warning and wavelength.

6.4. LS (Light Source)

The Light Source connects to the OTDR/LS port and is used for engineering and maintenance of optical fiber communication and CATV, fiber parameter setting, and optical component research. Modes include CW/270 Hz/330 Hz/1 kHz/2 kHz.

Light Source interface showing wavelength and mode settings

Image 6.4.1: Light Source interface with wavelength and modulation options.

6.5. OLT (Optical Loss Test)

The OLT function is used to test the insertion loss of optical passive devices. Calibrate by connecting the OTDR/LS port and OPM port with short fiber optic patch cables and clicking 'Start Test'. After stable power, click 'Set Parameter'.

Optical Loss Test interface showing connection diagram and measurement results

Image 6.5.1: Optical Loss Test setup and result display.

6.6. RJ45 Cable TDR Test

This function tests the status of RJ45 cable pairs (open or short circuit) and measures their length up to 600 meters. One end of the network cable should be connected to the OTDR tester, and the other end should not be connected to other devices.

Screenshots of RJ45 Cable TDR Test, Cable Length Test, and UTP Cable Tester functions

Image 6.6.1: RJ45 Cable TDR Test interface showing cable pair status and length.

6.7. UTP Cable Tester

Tests the connection status of UTP cables and displays results on the screen. It supports detecting near-end, mid-end, and far-end fault points of the RJ45 cable plug.

UTP Cable Tester interface showing cable connection status and fault detection

Image 6.7.1: UTP Cable Tester interface displaying cable connection status.

6.8. Cable Length Test

Measures the breakpoint position of open-circuit BNC cables, RJ45 network cables, and RJ11 cables. The maximum test length is 3000 meters. Note: The short-circuit status will not display the cable length. One end of the cable should be connected to the OTDR tester, and the other end should not be connected to other devices.

Cable Length Test interface showing measurement results

Image 6.8.1: Cable Length Test interface displaying measured cable length.

6.9. Network Test Tools

The MOT-51 includes several network testing utilities:

  • IP Address Scan: Quickly finds the IP addresses of connected IP cameras or other network devices. Supports MAC address and camera manufacturer identification.
  • PING Test: A conventional network debugging tool to verify if a connected IP camera or network device's Ethernet port is functioning correctly and if the IP address is valid. Connect a network cable to the LAN port and enable the PING tool.
  • LLDP (Link Layer Discovery Protocol): Detects capabilities, management IP addresses, device info, port info, and other information of switches. Requires the switch to support the LLDP protocol.
  • Port Flashing: Connect a network cable to the OTDR tester's "LAN" port. If the OTDR tester and PoE switch are connected, the LAN port of the PoE switch will flash, aiding in quickly locating the connected Ethernet cable.
  • PPPOE (Point-to-Point Protocol over Ethernet): Used to detect whether broadband PPPOE dialing is normal.
  • FTP File Management: Allows copying and editing files from the SD card without using an SD card reader. Start the FTP service and enter the tester's FTP address in the computer's address bar.
Screenshots of Network Test Tools including Ping, IP Scan, FTP, LLDP, Port Flashing, and PPPOE

Image 6.9.1: Network Test Tools interfaces.

7. Maintenance

  • Cleaning: Regularly clean the screen and exterior with a soft, dry cloth. For optical ports, use specialized fiber optic cleaning tools to prevent contamination.
  • Storage: Store the device in its protective tool bag in a cool, dry place away from direct sunlight and extreme temperatures.
  • Battery Care: If storing for extended periods, ensure the battery is partially charged (around 50%) and recharge every few months to maintain battery health.
  • Software Updates: Check the manufacturer's website periodically for firmware updates to ensure optimal performance and access to new features.

8. Troubleshooting

  • Device Not Powering On:
    • Ensure the battery isolation paper has been removed.
    • Check battery charge level. Connect to power and attempt to turn on.
    • Verify the battery is properly seated.
  • Inaccurate OTDR Readings:
    • Ensure optical connectors are clean and free of dust or debris.
    • Verify correct fiber type (single-mode) and wavelength settings.
    • Check that the fiber under test is not live. This model cannot test live fiber.
    • Adjust pulse width and distance range settings according to the fiber length.
  • VFL/LS Not Emitting Light:
    • Ensure the function is activated in the menu.
    • Check for any physical obstructions in the optical port.
  • RJ45 Cable Test Issues:
    • Ensure cables are properly terminated and connected.
    • For TDR tests, ensure the remote end is disconnected from other devices.
  • Touchscreen Unresponsive:
    • Restart the device.
    • Ensure the screen is clean and dry.

9. Specifications

FeatureSpecification
Model NumberMOT-51
OTDR Wavelength1310nm/1550nm
OTDR Dynamic Range26dB/24dB
Display5.55 inches Touchscreen
OPM Calibrated Wavelengths850/1300/1310/1490/1550/1625nm
VFL Wavelength650nm
VFL Max Test Range8 KM
LS ModesCW/270 Hz/330 Hz/1 kHz/2 kHz
RJ45 Cable TDR Test LengthMax 600 meters
Cable Length Test (BNC, RJ45, RJ11)Max 3000 meters
Battery3.7V/4000mAh Lithium Ion (included)
Ethernet PortSingle Gigabit, 10/100/1000Mbps adaptive
Power InputDC5V/2A
Power OutputDC5V/1A
Item Weight0.8 Kilograms
Dimensions10.28 x 5.94 x 4.13 inches

10. Warranty

WANLUTECH products are covered by a manufacturer's warranty against defects in materials and workmanship. Please retain your proof of purchase for warranty claims. Specific warranty duration and terms may vary by region. For detailed warranty information, please contact WANLUTECH customer support.

11. Support

For technical assistance, troubleshooting, or any questions regarding your WANLUTECH MOT-51 OTDR Fiber Tester, please contact our customer support team:

  • Amazon Order Support: Find your order on your Amazon account, view order details, and click 'get product support' to message us.
  • Direct Contact: You can find "WANGLU TESTER" on the product detail page, click on it, and then message us directly.

We aim to respond to all inquiries within 12 hours.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.