Rigol DHO804
RIGOL DHO804 Digital Oscilloscope User Manual
Model: DHO804
1. Introduction
The RIGOL DHO804 Digital Oscilloscope is a high-performance, compact instrument designed for precise signal analysis. It features a 70MHz frequency band, 12-bit vertical resolution, and four analog channels, making it suitable for a wide range of applications from embedded design to electronics maintenance and basic R&D. This manual provides essential information for setting up, operating, and maintaining your DHO804 oscilloscope.

Figure 1: Front view of the RIGOL DHO804 Digital Oscilloscope, showcasing its display and control panel.
2. Safety Information
Always observe the following safety precautions to prevent injury and damage to the instrument:
- Ensure the power supply voltage matches the instrument's requirements.
- Do not operate the instrument in wet or damp conditions.
- Avoid exposing the instrument to direct sunlight or extreme temperatures.
- Use only the probes and accessories supplied or recommended by RIGOL.
- Refer all servicing to qualified service personnel.
3. Package Contents
Verify that all items listed below are included in your package. If any items are missing or damaged, contact your supplier.
- Main Unit (DHO804) x1
- Probe x4
- Power Supply x1
- USB Cable x1
- Grounding Cable x1

Figure 2: Illustration of the DHO804 package contents, including the main unit, probes, power cable, data cable, grounding wire, and certificates.
4. Product Overview
The RIGOL DHO804 is part of the DHO800 series, known for its advanced features and compact design. Key features include:
- Ultra-low background noise for pure signal acquisition.
- 12-bit hardware high resolution across all channels.
- Up to 70 MHz analog bandwidth with 4 analog channels.
- Maximum 1.25 GSa/s real-time sampling rate.
- Storage depth up to 25 Mpts.
- Vertical sensitivity range of 500 µV/div to 10 V/div.
- Ultra Acquire mode providing up to 1 million wfms/s waveform capture rate.
- 7-inch 1024x600 high-definition touchscreen for intuitive interaction.
- Versatile interfaces: USB Device & Host, LAN, and HDMI ports.
4.1 Powering the Device
The DHO804 supports Type-C power input, allowing for flexible power options, including portable power sources for on-site testing.

Figure 3: The DHO804 oscilloscope connected to a portable power source via its Type-C port, highlighting its portability.
4.2 High-Definition Touchscreen
The 7-inch high-definition touchscreen enhances user interaction, providing a clear and responsive interface for waveform analysis and instrument control.

Figure 4: A hand interacting with the 7-inch HD touchscreen of the DHO804, demonstrating its touch capabilities.
4.3 Connectivity Options
The DHO800 series comes equipped with standard USB, LAN, and HDMI ports, facilitating remote control, data transfer, and external display connections for collaborative work.

Figure 5: Rear view of the DHO804 showing its USB, LAN, and HDMI ports, alongside a laptop displaying the remote control interface.
4.4 Compact and Sleek Design
The DHO804 features a compact form factor that supports standard monitor stand usage, effectively reducing desktop footprint and providing more ample workspace.

Figure 6: The DHO804 oscilloscope mounted on a monitor stand, illustrating its space-saving design.
4.5 Product Overview Video
Video 1: An official overview of the RIGOL DHO800 series, showcasing its design, key features, and user interface. This video highlights the compact size, high resolution, and various connectivity options.
5. Setup
- Unpacking: Carefully remove the oscilloscope and all accessories from the packaging. Retain the original packaging for future transport or storage.
- Power Connection: Connect the provided power cable to the Type-C port on the rear of the oscilloscope and then to a suitable power outlet.
- Probe Connection: Connect the probes to the BNC input connectors on the front panel. Ensure the probe compensation is adjusted for accurate measurements.
- Initial Power On: Press the power button to turn on the oscilloscope. The system will boot up and display the main waveform interface.
- Language Settings: If necessary, navigate to the system settings via the touchscreen to adjust the display language.
6. Operating the Oscilloscope
The DHO804 features a user-friendly interface with both physical controls and a responsive touchscreen. Here are basic operating principles:
- Channel Controls: Use the dedicated vertical scale and position knobs for each channel to adjust the waveform display.
- Horizontal Controls: Adjust the horizontal scale (time base) and position using the corresponding knobs to view different time segments of the signal.
- Trigger System: Set the trigger level and mode to stabilize repetitive waveforms. The trigger controls are located on the right side of the front panel.
- Measurement Functions: Access automatic measurements (e.g., Vpp, Freq, Period) via the 'Measure' button or touchscreen menu.
- Touchscreen Interaction: Tap, swipe, and pinch-to-zoom gestures can be used for navigating menus, adjusting settings, and analyzing waveforms directly on the screen.
- Saving Data: Use the USB host port to save waveform data, screenshots, or instrument settings to a USB flash drive.
7. Maintenance
Proper maintenance ensures the longevity and accuracy of your oscilloscope:
- Cleaning: Use a soft, damp cloth to clean the exterior of the instrument. Avoid abrasive cleaners or solvents. For the screen, use a specialized screen cleaner.
- Storage: When not in use, store the oscilloscope in a dry, dust-free environment. Protect the screen and connectors from physical damage.
- Software Updates: Periodically check the RIGOL official website for firmware updates to ensure optimal performance and access to new features. The instrument supports online version upgrades.
- Probe Care: Handle probes carefully. Avoid bending or stressing the cables excessively. Store them properly to prevent damage to the tips.
8. Troubleshooting
This section provides solutions to common issues you might encounter:
| Problem | Possible Cause | Solution |
|---|---|---|
| No display after power on | Power cable not connected; Power outlet faulty; Instrument fault. | Check power cable connection; Test power outlet; Contact service personnel. |
| No waveform displayed | Probe not connected; Input signal too small/large; Incorrect trigger settings. | Connect probe correctly; Adjust vertical scale; Adjust trigger level/mode. |
| Waveform unstable | Incorrect trigger source/mode; Signal noise. | Verify trigger settings; Reduce noise in signal path. |
| Touchscreen unresponsive | Temporary software glitch; Screen lock enabled. | Restart the instrument; Check for 'Touch Lock' function and disable if active. |
9. Specifications
Detailed technical specifications for the RIGOL DHO804 Digital Oscilloscope:
| Feature | Specification |
|---|---|
| Product Dimensions | 10.45 x 3.05 x 6.37 inches; 3.92 Pounds (265.36 x 77.38 x 161.75 mm; 1.78 kg) |
| Item Model Number | DHO804 |
| Manufacturer | RIGOL |
| Country of Origin | China |
| Bandwidth | 70 MHz |
| Vertical Resolution | 12-bit |
| Sample Rate | Up to 1.25 GSa/s |
| Analog Channels | 4 |
| Storage Depth | Up to 25 Mpts |
| Waveform Capture Rate | Up to 1,000,000 wfms/s (Ultra Acquire mode) |
| Display | 7-inch 1024 x 600 HD Touchscreen |
| Interfaces | USB Device & Host, LAN, HDMI |
| Serial Number Prefix | DHO8A262906640 (Example) |
| UPC/EAN | 6973332407530 (Example) |
10. Warranty and Support
The main body of RIGOL equipment provides a 3-year standard warranty from the date of purchase. For technical support, service, or warranty claims, please contact RIGOL customer service or visit their official website for detailed contact information and resources.
For further assistance, please refer to the official RIGOL website or contact their authorized distributors.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.