Digitus DN-49203

DIGITUS SOHO Pro 7U Network Cabinet

Model: DN-49203

1. Introduction

This manual provides detailed instructions for the assembly, installation, and operation of your DIGITUS SOHO Pro 7U Network Cabinet, Model DN-49203. Please read these instructions carefully before beginning assembly to ensure safe and correct installation.

Safety Information

  • Ensure all components are present and undamaged before assembly.
  • Always use appropriate tools and follow safety guidelines during installation.
  • The cabinet is designed for a maximum load capacity of 60 kg (132.3 lbs). Do not exceed this limit.
  • Wall mounting requires suitable fasteners for your wall type (not included). Consult a professional if unsure.
  • Keep children and pets away from the assembly area.
DIGITUS SOHO Pro 7U Network Cabinet, front view

Figure 1: Front view of the assembled DIGITUS SOHO Pro 7U Network Cabinet.

2. Product Features

The DIGITUS SOHO Pro 7U Network Cabinet offers a robust and versatile solution for housing network and server equipment.

  • Universal Compatibility: 19-inch rack with 7U height for standard network and server installations.
  • Adjustable Profile Rails: 483mm (19") profile rails on the front for flexible mounting of accessories, adjustable in depth.
  • Efficient Cable Management: Integrated cable entries with removable plastic caps at the top and bottom.
  • Secure Access: Lockable front door made of safety glass, providing protection against unauthorized access.
  • Passive Ventilation: Ventilation slots on the front and pre-drilled brackets for optional ceiling-mounted fan units.
  • Robust Construction: Made from durable sheet steel, supporting a maximum load of 60 kg.
  • Flexible Door Hinge: Door hinge can be changed to open from either side, with a 200° opening angle.
  • IP20 Rated: Protected against solid foreign objects larger than 12.5 mm.
Front view of the DIGITUS SOHO Pro 7U Network Cabinet with glass door closed

Figure 2: Front view of the cabinet with the glass door closed.

3. Assembly Instructions

The DIGITUS SOHO Pro Network Cabinet is delivered unassembled for optimized transport. Follow these steps for assembly.

3.1. Unpacking and Initial Setup

  1. Step 1: Unpack the Cabinet Components. Carefully remove all parts of the 19-inch SOHO cabinet from its packaging. Ensure all components are present and undamaged.
  2. Step 2: Open Side Panels. Open the hinged side panels of the cabinet body.
Assembly steps 1-4 for the DIGITUS SOHO Pro Network Cabinet

Figure 3: Visual guide for assembly steps 1-4.

3.2. Attaching Base and Door

  1. Step 3: Attach Bottom Panel. Slide the bottom plate onto the cabinet body, ensuring the recesses of the bottom plate align and insert into the gaps of the body. Secure the bottom panel to the body using the provided screws. For 9U/12U cabinets, ensure horizontal screws are mounted first, followed by vertical screws. Mount the plastic door stopper on the lock side of the glass door.
  2. Step 4: Install Glass Door (Bottom Hinge). Lay the cabinet body down with the bottom panel facing the backside. Insert the top hinge pin of the glass door into the hinge hole of the top panel.
Close-up of the door hinge mechanism on the DIGITUS SOHO Pro Network Cabinet

Figure 4: Detail of the door hinge installation.

3.3. Finalizing Assembly

  1. Step 5: Attach Top Panel. Slide the top panel onto the body, aligning the recesses. Insert the top hinge pin of the glass door into the hinge hole of the top panel. Ensure the top panel recesses are inserted into the panel gap of the body. Assemble the bottom panel to the body using 4 screws.
  2. Step 6: Position Cabinet. Place the cabinet upright on the floor. Bend the recesses of the bottom panel downwards and the recesses of the top panel upwards to secure.
  3. Step 7: Installation Video. For a visual guide, scan the QR code or visit the provided link to watch the installation video. Your SOHO cabinet is now ready for use.
Assembly steps 5-7 for the DIGITUS SOHO Pro Network Cabinet, including QR code for video

Figure 5: Visual guide for assembly steps 5-7.

Installation Video

Watch the official DIGITUS installation video for a step-by-step visual guide to assembling your SOHO Pro Network Cabinet.

3.4. Wall Mounting

The cabinet is designed for wall mounting. Ensure the wall can support the cabinet's weight plus the weight of installed equipment (up to 60 kg total).

  • Identify suitable mounting points on the back of the cabinet.
  • Mark the drilling locations on the wall using the cabinet as a template.
  • Drill holes and insert appropriate wall anchors (not supplied).
  • Secure the cabinet to the wall using screws.
Rear view of the DIGITUS SOHO Pro Network Cabinet showing wall mounting points

Figure 6: Rear view of the cabinet indicating wall mounting points.

4. Operation

4.1. Installing Equipment

  • Open the front glass door using the provided key.
  • Adjust the depth of the 19-inch profile rails as needed to accommodate your equipment.
  • Mount your 19-inch compatible devices (e.g., switches, patch panels, servers) to the profile rails using appropriate rack screws (not included).
Interior view of the DIGITUS SOHO Pro Network Cabinet with the glass door open, showing adjustable rails

Figure 7: Interior view with the glass door open, highlighting adjustable profile rails.

4.2. Cable Management

  • Utilize the cable entry points located at the top and bottom of the cabinet for routing network cables.
  • Remove the plastic caps from the cable entries as needed.
  • Ensure cables are neatly organized and secured to prevent strain or interference.
Close-up of the cable entry point at the base of the DIGITUS SOHO Pro Network Cabinet

Figure 8: Detail of the cable entry at the base.

4.3. Ventilation

  • The cabinet features passive ventilation through slots on the front.
  • For enhanced cooling, optional fan units can be installed in the pre-drilled brackets on the ceiling of the cabinet.
Top view of the DIGITUS SOHO Pro Network Cabinet showing fan cutouts and cable entry

Figure 9: Top view showing fan cutouts and cable entry.

5. Maintenance

  • Cleaning: Wipe the exterior surfaces with a soft, damp cloth. Avoid abrasive cleaners or solvents.
  • Inspection: Periodically check all screws and fasteners to ensure they are tight. Inspect the door hinges and lock for proper function.
  • Ventilation: Ensure ventilation slots are not obstructed to maintain proper airflow.

6. Troubleshooting

Most issues with the network cabinet are related to assembly or installation. Refer to the assembly instructions if you encounter any difficulties.

  • Cabinet is wobbly after assembly: Recheck all screw connections to ensure they are tightened securely. Ensure the cabinet is placed on a level surface or properly mounted to the wall.
  • Door does not close properly: Verify that the door hinges are correctly installed and aligned. Check for any obstructions. The door hinge can be adjusted or reversed if needed.
  • Difficulty inserting equipment: Ensure the 19-inch profile rails are correctly positioned and adjusted to the required depth.

7. Specifications

Attribute Value
Brand Digitus
Model Number DN-49203
Size 7U
Color Black/White
Product Dimensions (D x W x H) 15.75"D x 21.26"W x 14.57"H (400mm D x 540mm W x 370mm H)
Useful Depth 327mm
Material Metal
Item Weight 9.4 Kilograms (20.7 lbs)
Weight Capacity 60 kg (132.3 lbs)
Mounting Type Rack Mount, Wall Mount
Enclosure Material Metal
Assembly Required Yes

8. Warranty and Support

For warranty information and technical support, please refer to the documentation included with your purchase or visit the official Digitus website. Keep your proof of purchase for warranty claims.

If you have further questions or require assistance, please contact Digitus customer service.

© 2024 Digitus. All rights reserved.

Related Documents - DN-49203

Preview DIGITUS Wall Housing SOHO PRO Series Quick Installation Guide
Step-by-step instructions for installing the DIGITUS Wall Housing SOHO PRO Series network cabinets, including models DN-49100 through DN-49105.
Preview DIGITUS Shielded Patch Panel Installation Guide
Comprehensive installation guide for DIGITUS shielded patch panels, covering strain relief, cable fixing, and connection procedures. Includes product specifications and RoHS compliance information.
Preview DIGITUS 2-Port Wireless USB 2.0 300 Mb/s Network Server Quick Installation Guide
This guide provides instructions for installing and configuring the DIGITUS 2-Port Wireless USB 2.0 300 Mb/s Network Server. It covers hardware installation, software setup, and usage for printing and scanning.
Preview DIGITUS Mobile Charging Cabinet for Notebooks and Tablets - User Manual
User manual for the DIGITUS mobile charging cabinet, designed for storing and charging notebooks and tablets up to 14/15.6 inches. Features include secure storage, USB charging ports, AC outlets, and efficient cooling.
Preview DIGITUS Plug&View IP Cameras Quick Installation Guide
This Quick Installation Guide provides step-by-step instructions for setting up and configuring DIGITUS Plug&View IP Cameras. Learn about safety precautions, camera connections, user account creation, Wi-Fi setup, and motion detection features for models like DN-16029, DN-16039, DN-16043, DN-16048, DN-16049, DN-16047, and DN-16046.
Preview DIGITUS Layer 2 Industrial Switch Web Configuration Manual
This manual provides detailed instructions for configuring the DIGITUS Layer 2 Industrial Switch, covering aspects from initial login to advanced network management features like VLANs, QoS, and security protocols.