FeelTech FY2300 12M

FeelTech FY2300 12M Digital DDS Dual-Channel Function/Arbitrary Waveform Generator User Manual

Model: FY2300 12M

1. Introduction

1.1 Product Overview

The FeelTech FY2300 12M is a digital DDS (Direct Digital Synthesizer) dual-channel function/arbitrary waveform generator. It is designed to produce accurate and stable signals with low distortion, suitable for various testing and measurement applications. This device features a compact design, a color LCD display, and offers comprehensive waveform generation capabilities.

1.2 Key Features

  • Adopts DDS technology for accurate, stable signals with low distortion.
  • Equipped with a 2.4-inch TFT Color LCD display with 320×240 resolution.
  • Portable design with a durable aluminum alloy shell.
  • Supports frequencies up to 12MHz (for the 12M model) with a 200MSa/s sampling rate and 12-bit vertical resolution.
  • Features complete independent dual channels that can operate simultaneously with adjustable phase difference.
FeelTech FY2300 12M Digital DDS Dual-Channel Function/Arbitrary Waveform Generator
Figure 1.1: FeelTech FY2300 12M Digital DDS Dual-Channel Function/Arbitrary Waveform Generator.

2. Safety Notes

Please read and understand the following safety precautions before operating the device to ensure safe and proper use.

  • Power Supply: Ensure the power supply voltage is within the specified range (DC 5V) and stable. Using an incorrect power adapter may damage the instrument.
  • Environment: Operate the instrument in a dry, well-ventilated area, away from direct sunlight, high temperatures, humidity, and corrosive gases.
  • Handling: Avoid strong vibrations or impacts to the instrument. Do not disassemble or modify the device without authorization.
  • Maintenance: Refer all servicing to qualified personnel. Do not attempt repairs yourself.
  • Personal Injury: Do not apply the product in safety-critical applications where product failure could result in personal injury or death. The manufacturer is not responsible for any personal injury or damage caused by improper use or unauthorized modifications.

3. Product Overview

3.1 Front Panel and Interfaces

FeelTech FY2300 12M Front and Rear Panel with Labeled Components
Figure 3.1: Front and Rear Panel Layout with Component Descriptions.

The following table describes the numbered components shown in Figure 3.1:

NO.DescriptionNO.Description
1Function button area8USB communication interface
2Color LCD display9Power Switch (ON/OFF)
3Menu10CH2 output port
4Arrow keys11CH1 output port
5Channel control switch12External measurement port (EXT.IN)
6Adjustment knob/OK key13TTL input/output port (TTL_IO)
7DC 5V power supply interface

4. Setup

4.1 Initial Connection

  1. Power Connection: Connect the provided DC 5V power adapter to the DC 5V power supply interface (7) on the rear panel.
  2. Power On: Flip the power switch (9) to the 'ON' position. The LCD display (2) should illuminate.
  3. Output Connection: Connect your test leads or oscilloscope probes to the desired output channels (CH1 (11) or CH2 (10)) using BNC connectors.
  4. USB Connection (Optional): For PC control, connect the USB communication interface (8) to your computer using the provided USB cable.

4.2 Basic Interface Navigation

Use the function buttons (1), arrow keys (4), and the adjustment knob/OK key (6) to navigate through the menus and adjust parameters on the color LCD display (2).

5. Operating Instructions

5.1 Basic Waveform Generation

To generate a standard waveform (e.g., Sine, Square, Triangle):

  1. Press the WAVE button (part of 1) to select the desired waveform type.
  2. Use the arrow keys (4) to navigate to parameters such as Frequency (FREQ), Amplitude (AMPL), Offset (OFFS), and Duty Cycle (DUTY).
  3. Turn the adjustment knob (6) to change the value of the selected parameter. Press the knob to confirm or switch between coarse/fine adjustment.
  4. Ensure the desired channel (CH1 or CH2) is enabled using the channel control switch (5).

5.2 Advanced Waveform Generation (Arbitrary Waveform)

The FY2300 supports arbitrary waveform generation. This typically involves creating a custom waveform using PC software and then uploading it to the device.

PC software interface for drawing arbitrary waveforms and corresponding oscilloscope display
Figure 5.1: PC software for arbitrary waveform creation and oscilloscope output.

As shown in Figure 5.1, you can draw an arbitrary waveform in the PC software's waveform window and then click "Send Waveform Data" to transfer it to the generator. The generator's display will show the waveform parameters, and an oscilloscope can visualize the output.

5.3 Sweep Function

The sweep function allows the frequency, amplitude, offset, or duty cycle to change over a specified range and time.

  1. Press the SWEEP button (part of 1).
  2. Configure the sweep type (Linear or Logarithm), sweep objects (Frequency, Amplitude, Offset, Duty Cycle), starting and finishing positions, and sweep time.
  3. Activate the sweep function.

5.4 Measurement Function

The MEAS button (part of 1) allows access to measurement functions, typically for external signals connected to the EXT.IN port (12).

6. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the exterior of the instrument. Do not use abrasive cleaners or solvents.
  • Storage: When not in use for extended periods, store the device in a cool, dry place, away from dust and extreme temperatures.
  • Calibration: Regular calibration by qualified personnel is recommended to maintain accuracy, especially in professional applications.
  • Firmware Updates: Check the manufacturer's website periodically for firmware updates that may improve performance or add features.

7. Troubleshooting

If you encounter issues with your FeelTech FY2300 12M, refer to the following common problems and solutions:

  • No Power:
    • Ensure the power adapter is correctly connected to the DC 5V port.
    • Verify the power switch is in the 'ON' position.
    • Check if the power adapter is functioning correctly.
  • No Output Signal:
    • Confirm that the desired channel (CH1 or CH2) is enabled.
    • Check the output cable connections to the oscilloscope or load.
    • Verify that the amplitude and frequency settings are not set to zero or an invalid range.
  • Incorrect Waveform Display:
    • Ensure the oscilloscope settings (time base, voltage scale) are appropriate for the generated waveform.
    • Check for proper impedance matching between the generator and the load.
  • PC Software Connection Issues:
    • Verify the USB cable is securely connected to both the device and the computer.
    • Ensure the correct USB driver is installed on your computer.
    • Check the COM port settings in the PC software.

If the problem persists, contact customer support for further assistance.

8. Specifications

8.1 Frequency Parameters

Table of Frequency Parameters for FY2300 series
Figure 8.1: Frequency Parameters.

The table above details the frequency ranges and resolutions for various waveform types across different FY2300 models. For the FY2300 12M model, the maximum sine wave frequency is 12MHz.

8.2 Waveform Characteristics

Table of Waveform Characteristics for FY2300 series
Figure 8.2: Waveform Characteristics.

Figure 8.2 provides an overview of the waveform types supported, waveform length, sampling rate, vertical resolution, and specific characteristics for sine, square, and sawtooth waves.

8.3 General Specifications

ParameterValue
Display2.4 inch TFT Color Display
Save & Load Amount20 (01 to 20, 01 for default)
Interface TypeUSB to Serial interface
Communicating Speed9600bps
ProtocolCommand line mode, protocol complete open
Power Supply Voltage RangeDC5V±0.5V
BuzzerCan be turned on/off by setting
Environment Temp.0~40°C
Environment Humidity< 80%
Size (L*W*H)140 × 95 × 54.2mm / 5.51 × 3.74 × 2.13in
Weight419g / 14.8oz
Package Size (L*W*H)22.5 × 15 × 7.5cm / 8.86 × 5.9 × 2.95in
Package Weight700g / 24.7oz

9. Accessories and Options

FeelTech FY2300 12M with included accessories and manual
Figure 9.1: Product with included accessories and manual.

The following table lists the standard accessories included with the FY2300 12M and available options:

DescriptionQuantity
Standard Accessories
5V 1A Power Adapter1
USB-B Data/Power Cable1
BNC-Clip Cable2
Resource CD (including User's Manual)1
Warranty Card1
Options
BNC-BNC CableOptional
FYA2000/FPA1000 Series AmplifierOptional

Note: Options can be ordered from local FeelTech distributors.

10. Warranty and Support

10.1 Warranty Information

This product comes with a standard manufacturer's warranty. Please refer to the included warranty card for specific terms, conditions, and duration of coverage. Retain your proof of purchase for warranty claims.

10.2 Customer Support

For technical assistance, troubleshooting not covered in this manual, or warranty inquiries, please contact FeelTech customer support through their official website or the contact information provided on the warranty card.

© 2024 FeelTech. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.