1. Product Overview
The FeelTech FY6200 20M is a versatile Dual Channel DDS (Direct Digital Synthesis) Signal Generator and Frequency Counter. It features a maximum output frequency of 20MHz for sine waves, a 250MSa/s sampling rate, and 14-bit vertical resolution. This instrument is designed for generating various waveforms including sine, square, triangular, pulse, and arbitrary waveforms, with a full-range frequency resolution of 1µHz. It also includes a frequency counter and supports arbitrary waveform editing.

Figure 1: The FeelTech FY6200 20M Dual Channel DDS Signal Generator, shown with its standard accessories including BNC cables, USB cable, and power adapter.
2. Setup and Initial Connection
- Unpacking: Carefully remove the signal generator and all accessories from the packaging. Verify that all components listed in the packing list are present.
- Power Connection: Connect the provided power adapter to the DC input port on the rear panel of the device. Plug the adapter into a suitable power outlet.
- Power On: Press the power button located on the front panel to turn on the device. The 3.2-inch color screen will illuminate.
- Output Connections: Connect BNC cables to the CH1 Output1 and CH2 Output2 ports for waveform generation. The OK Counter port is for frequency counting input.
- USB Connection (Optional): For PC control or firmware updates, connect the device to a computer using the provided USB cable.

Figure 2: Rear panel of the FY6200 20M, illustrating the DC power input and USB communication port.
3. Operating Instructions
3.1 Front Panel Controls
The front panel features a 3.2-inch color screen, navigation buttons, a rotary encoder, and dedicated function buttons for easy operation.
- Screen: Displays waveform parameters, system settings, and measurement results.
- Rotary Encoder: Used for adjusting parameter values. Turn clockwise to increase, counter-clockwise to decrease.
- Navigation Buttons: Arrow keys for menu navigation and parameter selection.
- Function Buttons (SAVE, LOAD, SYNC, CONF, MORE): Access various system and waveform management functions.
- Waveform Selection Buttons (WAVE, MOD, SWEEP, VCO, COUNTER, SYSTEM): Select the desired operating mode or waveform type.

Figure 3: Front view of the FY6200 20M, highlighting the display, control buttons, and output ports.
3.2 Generating Basic Waveforms
- Select Channel: Use the CH1 or CH2 buttons to select the desired output channel.
- Select Waveform: Press the WAVE button to cycle through available waveform types (Sine, Square, Triangle, etc.).
- Adjust Frequency: Use the navigation buttons to highlight the frequency parameter. Turn the rotary encoder to set the desired frequency. The resolution is 1µHz.
- Adjust Amplitude: Highlight the amplitude parameter and use the rotary encoder to set the peak-to-peak voltage. The pulse amplitude can be continuously adjusted between 0~10V with 0.001V accuracy.
- Adjust Duty Cycle/Phase: For waveforms like square or pulse, adjust the duty cycle. For sine waves, phase can be adjusted.
- Enable Output: Ensure the output for the selected channel (CH1 Output1 or CH2 Output2) is enabled.
3.3 Arbitrary Waveform Editing
The FY6200 supports user-defined arbitrary waveforms. It can store 64 user-defined arbitrary waveforms, each with a length of 8192 points (8K points) and 14-bit vertical resolution.
- Access Arbitrary Waveform Mode: Press the WAVE button until 'Arbitrary Wave' is selected.
- Edit Waveform: Use the system menu or PC software (if available) to define or load arbitrary waveform data. Refer to the detailed software manual for specific instructions on creating and uploading arbitrary waveforms.
- Save/Load: Use the SAVE and LOAD buttons to manage stored arbitrary waveforms.
3.4 Frequency Counter Function
The device includes a frequency counter function.
- Connect Input: Connect the signal to be measured to the OK Counter input port.
- Select Counter Mode: Press the COUNTER button to activate the frequency counter. The screen will display the measured frequency.

Figure 4: The system settings screen of the FY6200 20M, showing options for model, version, language, buzzer, uplink, and sync settings. This screen also provides the manufacturer's website for more information.
4. Maintenance
- Cleaning: Use a soft, dry cloth to clean the exterior of the device. Do not use abrasive cleaners or solvents.
- Storage: Store the device in a cool, dry environment away from direct sunlight and extreme temperatures.
- Battery: The device includes a Lithium Metal battery. Follow local regulations for battery disposal if replacement is ever needed.
- Calibration: For optimal accuracy, periodic calibration by qualified personnel is recommended.
5. Troubleshooting
- No Power:
- Ensure the power adapter is securely connected to both the device and a working power outlet.
- Verify the power button is pressed.
- No Output Signal:
- Check that the output channel (CH1 or CH2) is enabled on the device.
- Verify BNC cables are correctly connected to the output ports and the receiving instrument.
- Confirm that frequency and amplitude parameters are set to valid values.
- Incorrect Frequency Counter Reading:
- Ensure the input signal is within the specified voltage and frequency range for the counter.
- Check the connection to the OK Counter port.
- Display Issues:
- If the display is frozen or unresponsive, try restarting the device.
6. Specifications

Figure 5: Detailed frequency and waveform characteristics for the FY6200 series, including the 20M model.
| Feature | Specification |
|---|---|
| Model Number | GT-FY6200 20M |
| Maximum Sine Wave Frequency | 20 MHz |
| Sampling Rate | 250 MSa/s |
| Vertical Resolution | 14 bits |
| Frequency Resolution | 1 µHz (0.000001 Hz) |
| Frequency Accuracy | ±20 ppm |
| Frequency Stability | ±1 ppm / 3 hours |
| Pulse Amplitude Adjustment | 0~10V (0.001V accuracy) |
| Waveform Catalog | Sine, Square, Triangle, Pulse, Arbitrary, TTL/CMOS Digital, Rising/Falling Sawtooth, DC Level, Half Wave, Full Wave, Positive/Negative Ladder, Anti-Ladder, Exponential Rise/Fall, Lorentz Pulse, Multi-Sound, Irregular Noise, ECG, Trapezoid Pulse, Cinke Pulse, Narrow Pulse, Gaussian White Noise, AM, FM, and 64 user-defined waveforms. |
| Nonvolatile Storage | 64 user-defined arbitrary waveforms |
| Waveform Length | 8192 points (8K points) |
| Display | 3.2-inch (320*240) color screen |
| Product Dimensions | 9.84 x 7.87 x 5.91 inches |
| Weight | 2.2 Pounds |
| Batteries | 1 Lithium Metal battery (included) |
7. Warranty and Support
This FeelTech product is covered by the manufacturer's standard warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official FeelTech website. For technical support, troubleshooting assistance, or service inquiries, please contact FeelTech customer service or visit their official website: