VEVOR BT-BPT190AL
Contents
VEVOR 80 CFM Bathroom Exhaust Fan User Manual
Model: BT-BPT190AL | Brand: VEVOR
1. Introduction
Thank you for choosing the VEVOR 80 CFM Bathroom Exhaust Fan. This manual provides essential information for the safe installation, operation, and maintenance of your new ventilation fan. Please read it thoroughly before use and retain it for future reference.
This high-efficiency exhaust fan is designed to provide superior ventilation, reduce humidity, eliminate odors, and prevent fogging in bathrooms up to 85 sq.ft. It features an integrated LED light with adjustable color temperatures and operates quietly for a comfortable environment.
2. Safety Information
WARNING: To reduce the risk of fire, electric shock, or injury to persons, observe the following:
- Read all instructions before installing or servicing this fan.
- Always disconnect power at the service panel before wiring or servicing.
- This unit must be grounded.
- Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
- Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel-burning equipment to prevent back-drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
- When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
- Ducted fans must always be vented to the outdoors.
- Do not use this fan with any solid-state speed control device.
- This fan is intended for general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
- To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc., off power unit.
- This product is designed for ceiling mount installation only.
3. Package Contents
Verify that all components are present and undamaged before beginning installation.
- 1 x VEVOR Bathroom Exhaust Fan (Model: BT-BPT190AL)
- 1 x Double Switch (Includes 2 switch installation screws)
- 1 x User Manual (This document)
- 4 x Flat Head Screws M4*30mm
Image: VEVOR Bathroom Exhaust Fan, showing its dimensions and the included components like the double switch, user manual, and screws.
4. Specifications
| Brand | VEVOR |
| Model Number | BT-BPT190AL |
| Air Flow Capacity | 80 Cubic Feet Per Minute (CFM) |
| Noise Level | 33 Decibels (1.5 Sones) |
| Wattage | 48 watts |
| Voltage | 120 Volts (AC) |
| Product Dimensions (D x W x H) | 11.4" x 6.7" x 10" (290 x 170 x 255 mm) |
| Ceiling Cutout Dimensions | 7.68" x 7.6" (195 x 193 mm) |
| Recommended Room Size | Up to 85 sq.ft |
| Light Type | LED, 900 Lumens |
| Color Temperature | 3000K/4000K/5000K (Adjustable) |
| Housing Material | Galvanized Steel |
| Blade Material | Plastic (PPFR) |
| Control Method | Double Wall Switch (Fan/Light) |
| Weight | 6.8 lbs (3.08 kg) |
Image: Overview of the VEVOR 80 CFM Bathroom Exhaust Fan.
5. Setup and Installation
This exhaust fan is designed for easy ceiling-mounted installation, often without the need for attic access. Follow these steps carefully.
5.1 Prepare the Ceiling Opening
- Mark and cut a ceiling opening of 7.68 x 7.6 inches (195 x 193 mm). Ensure there are no electrical wires or other obstructions in the cutting area.
Image: Visual guide showing the six main steps for installing the VEVOR Bathroom Exhaust Fan, including preparing the opening, securing the fan, connecting wiring, installing ductwork, attaching the panel, and final installation.
5.2 Secure the Exhaust Fan
- Insert the exhaust fan into the prepared ceiling opening.
- Secure the fan housing to a ceiling joist or beam using the provided screws. Ensure the fan is firmly mounted to prevent vibration and noise.
5.3 Electrical Wiring
IMPORTANT: All wiring must comply with local electrical codes. If you are unsure, consult a qualified electrician.
- Connect the fan's wiring to your household wiring. Match the corresponding wire colors:
- Black (Live) to Black (Live)
- White (Neutral) to White (Neutral)
- Green (Ground) to Green (Ground)
- If using the included double switch, connect the fan and light wires to the switch terminals as per the switch wiring diagram.
Video: Detailed installation guide for the VEVOR 80 CFM Bathroom Exhaust Fan, demonstrating steps like securing the unit, connecting electrical wires, and attaching ductwork.
5.4 Install Ductwork
- Connect a 4-inch exhaust duct (not included) to the fan's duct connector. Secure it with tape or clamps to ensure an airtight seal.
- Route the ductwork to an exterior vent cap. Ensure the duct run is as short and straight as possible to maximize airflow efficiency.
5.5 Attach the Decorative Panel
- Connect the lighting wire from the fan housing to the decorative panel's light connector.
- Carefully snap the decorative panel onto the fan housing. Ensure it is flush with the ceiling.
Image: The VEVOR Bathroom Exhaust Fan installed in a modern bathroom, showcasing its minimalist white design that blends with various ceilings.
6. Operating Instructions
Once installed, the VEVOR Bathroom Exhaust Fan is ready for operation.
6.1 Fan and Light Control
- Use the included double wall switch to independently control the fan and the LED light. One switch operates the fan, and the other operates the light.
- The fan operates at a single speed (80 CFM).
Image: The VEVOR Bathroom Exhaust Fan's LED light displaying three adjustable color temperatures: Warm Color (3000K), Neutral Color (4000K), and Cool Color (5000K), providing 900 lumens of illumination.
6.2 Adjusting LED Color Temperature
The LED light offers three color temperature options (3000K, 4000K, 5000K). To cycle through these options, quickly toggle the light switch OFF and ON. The light will change to the next color temperature in sequence.
6.3 Optimal Usage
- For effective moisture and odor removal, operate the fan during and after showering or bathing for at least 15-20 minutes.
- The fan's quiet operation (1.5 Sones / 33 dB) ensures minimal disturbance.
Image: Graphic illustrating the low noise operation of the VEVOR Bathroom Exhaust Fan, showing its sound level at 33dB (1.5 Sones) compared to other common sounds.
7. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your exhaust fan. Always disconnect power before performing any maintenance.
7.1 Cleaning the Grille and Light Cover
- Remove the decorative panel by gently pulling it down.
- Wipe the grille and light cover with a soft cloth dampened with mild soap and water. Do not use abrasive cleaners.
- Ensure the parts are completely dry before reattaching.
7.2 Cleaning the Fan Blades and Motor
- With the power disconnected, carefully reach into the fan housing.
- Wipe the fan blades and motor housing with a damp cloth. Avoid getting water directly into the motor.
- The all-copper motor is designed for durability and stable performance.
Image: Diagram showing the internal components of the VEVOR Bathroom Exhaust Fan, highlighting the high-quality all-copper motor and lightweight plastic PPFR blades, emphasizing powerful yet quiet operation.
7.3 Housing Durability
The galvanized steel housing provides excellent moisture and corrosion resistance, ensuring durability in humid bathroom environments.
Image: The VEVOR Bathroom Exhaust Fan shown in a humid shower environment, illustrating its galvanized steel housing and resistance to moisture and corrosion.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Fan does not operate. | No power, loose wiring, faulty switch. | Check circuit breaker. Ensure all wiring connections are secure. Test or replace the wall switch. |
| Light does not turn on. | No power to light, loose wiring, faulty LED driver. | Check circuit breaker. Ensure light wiring connections are secure. Contact customer support if LED driver is suspected faulty. |
| Fan is noisy. | Loose mounting, debris in fan blades, improper ducting. | Ensure fan is securely mounted. Clean fan blades. Check ductwork for obstructions or kinks. |
| Poor ventilation. | Duct obstruction, undersized fan for room, excessive duct length/bends. | Check ductwork for blockages. Ensure room size is within recommended limits (up to 85 sq.ft). Optimize duct path. |
9. Warranty and Support
VEVOR products are designed for durability and performance. For warranty information and technical support, please refer to the official VEVOR website or contact their customer service directly.
- Official Website: www.vevor.com
- Support Page: www.vevor.com/support
Please have your model number (BT-BPT190AL) and purchase date available when contacting support.
Documents and downloads
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.
