IXITAB KWS-AC301, KWS-AC300

IXITAB KWS-AC301 & KWS-AC300 Digital AC Power Energy Meter User Manual

Models: KWS-AC300, KWS-AC301, KWS-AC301L

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the IXITAB KWS-AC301 and KWS-AC300 series Digital AC Power Energy Meters. These devices are designed to measure and display various electrical parameters including voltage, current, power, energy consumption (Kwh), timing, temperature, frequency, and power factor (for KWS-AC301 models). Please read this manual thoroughly before use to ensure proper and safe operation.

2. Safety Information

  • Ensure all power is disconnected before installation or wiring to prevent electric shock.
  • Installation should only be performed by qualified personnel.
  • Do not operate the device in wet or damp conditions.
  • Do not exceed the specified voltage and current ratings of the meter.
  • Verify all connections are secure before applying power.

3. Product Features

The IXITAB KWS-AC300 and KWS-AC301 series meters offer comprehensive monitoring of AC electrical parameters:

  • Real-time display of AC Voltage (V), Current (A), and Active Power (W).
  • Measurement of cumulative Electrical Energy (Kwh) and Timing (H).
  • Temperature measurement.
  • Frequency measurement (Hz).
  • Power Factor measurement (PF) (KWS-AC301 models only).
  • Electrical energy and timing reset function.
  • Power-down memory function for electrical energy and timing.
  • Optional 485 communication interface for data transmission (KWS-AC301L models).

4. Specifications

KWS-AC300 Series

ParameterAC300-20AAC300-100A
VoltageAC 50-300VAC 50-300V
Current0-20A0-100A
Power0-3000W0-30KW
Capacity (Kwh)0.01-19999Kwh0.01-19999Kwh
Timing0-200H0-200H
Temperature-10°C to 99°C-10°C to 99°C
Frequency45-65Hz45-65Hz

KWS-AC301 Series

ParameterAC301-20A / AC301L-20AAC301-100A / AC301L-100A
VoltageAC 50-300VAC 50-300V
Current0-20A0-100A
Shunt WayBuilt-inBuilt-in
485 CommunicationAC301-20A: No, AC301L-20A: YesAC301-100A: No, AC301L-100A: Yes
Power0-4400W0-22KW
Capacity (Kwh)0.01-99999Kwh0.01-99999Kwh
Timing0-999H0-999H
Temperature-10°C to 150°C-20°C to 150°C
Frequency50-60Hz50-60Hz
Power Factor0.01-1PF0.01-1PF

Note: Dimensions for KWS-AC300 are approximately 79mm x 37.5mm x 20.7mm. Dimensions for KWS-AC301 are approximately 73mm x 44mm x 24mm. Both models use a CT coil with a diameter of 15mm.

Dimensions of KWS-AC300 and KWS-AC301 meters and their CT coils

Figure 4.1: Physical dimensions of KWS-AC300 and KWS-AC301 models, including CT coil measurements.

5. Package Contents

  • 1 x Digital AC Power Energy Meter (KWS-AC300 or KWS-AC301 model)
  • 1 x User Manual
  • For 100A models: 1 x 100A Shunt / CT Coil
  • For 20A models: No external shunt/CT Coil (built-in)

6. Setup and Installation

Follow these steps carefully for proper installation:

6.1 Wiring Diagram (KWS-AC301L-100A Example)

The following diagram illustrates the wiring for the KWS-AC301L-100A model with a closed sensor (CT coil). Ensure all connections are made correctly before applying power.

Wiring diagram for KWS-AC301L-100A with closed sensor and CT coil

Figure 6.1: Wiring connections for the KWS-AC301L-100A model, showing input voltage (IN-AC), load connection, and CT coil placement around the live wire.

  • Power Input: Connect the AC 50-300V power supply to terminals L and N (typically labeled 3 and 4 on the meter).
  • Load Connection: Connect the load in series with the live wire (L). The CT coil should be placed around the live wire that feeds the load.
  • CT Coil: Connect the CT coil wires to the designated CT terminals on the meter (typically labeled 1 and 2). Ensure the direction of the CT coil is correct as indicated by any arrows on the coil or meter.
  • 20A Models: For 20A models without an external CT coil, the current measurement is internal. Connect the AC 50-300V power supply to the meter's input terminals, and the load directly through the meter's designated load terminals.

6.2 485 Communication and Temperature Sensor (KWS-AC301L Models)

For KWS-AC301L models, additional interfaces are available for 485 communication and an external temperature sensor.

KWS-AC301L with 485 communication and temperature sensor interfaces

Figure 6.2: KWS-AC301L model showing the dedicated interfaces for the temperature sensor and 485 communication (RS485 A+ and B- terminals).

  • Temperature Sensor: Connect the external temperature sensor to the dedicated interface.
  • 485 Interface: Connect the RS485 A+ and B- terminals to your 485 communication network for data acquisition. PC software may be available for data logging and analysis (refer to product documentation or manufacturer's website for download links).

7. Operation

The meter features a clear digital display and intuitive buttons for navigation and settings.

7.1 Display Overview

KWS-AC300 and KWS-AC301 meter displays showing various parameters

Figure 7.1: Top display shows KWS-AC300 with Voltage, Current, Power, Timing, and Kwh. Bottom display shows KWS-AC301 with Voltage, Current, Power, Timing, Kwh, Power Factor, and Frequency.

The display shows various parameters simultaneously. The KWS-AC300 typically displays Voltage, Current, Power, Timing, and Kwh. The KWS-AC301 models additionally display Frequency and Power Factor.

7.2 Button Functions

The meters typically feature one or more buttons for interaction:

  • KWS-AC300: Features a "MENU" button. Pressing this button allows cycling through display modes or accessing settings.
  • KWS-AC301: Features three buttons: Up (Δ), Middle (M), and Down (∇).
KWS-AC301 button interaction for settings and alarm values

Figure 7.2: KWS-AC301 button interaction. Pressing the 'M' button for 3 seconds allows entry into setting or alarm value adjustment modes.

  • "M" Button (KWS-AC301):
    • Short Press: Cycles through different display parameters (e.g., Voltage, Current, Power, Kwh, Timing, Temperature).
    • Long Press (3 seconds): Enters the setting mode or alarm value adjustment mode. Use the Up (Δ) and Down (∇) buttons to navigate and adjust values.
  • Up (Δ) and Down (∇) Buttons (KWS-AC301): Used to navigate menus, increase or decrease values in setting modes.

7.3 Resetting Electrical Energy and Timing

To reset the cumulative electrical energy (Kwh) and timing (H) values, typically a long press on a specific button (often the "M" or "MENU" button) while in the Kwh or Timing display mode will initiate the reset process. Confirm the reset if prompted by the display.

8. Maintenance

  • Keep the meter clean and free from dust. Use a soft, dry cloth for cleaning.
  • Avoid exposing the device to extreme temperatures, direct sunlight, or corrosive environments.
  • Do not attempt to open or repair the meter yourself, as this may void the warranty and pose a safety risk.
  • Ensure all wiring connections remain secure over time.

9. Troubleshooting

  • No Display:
    • Check if the power supply (AC 50-300V) is connected correctly and active.
    • Ensure the input voltage is within the specified range.
  • Incorrect Current/Power Reading:
    • For 100A models, verify the CT coil is correctly installed around the live wire and connected to the meter.
    • Ensure the CT coil direction is correct.
    • Check if the load is properly connected.
  • Parameters Not Resetting:
    • Refer to Section 7.3 for the correct procedure to reset Kwh and Timing. Ensure the button is pressed for the required duration.
  • 485 Communication Issues (KWS-AC301L):
    • Verify the A+ and B- connections are correct.
    • Check communication settings (baud rate, parity, stop bits) on both the meter and the connected device.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the manufacturer or your authorized dealer. Keep your purchase receipt as proof of purchase.

Manufacturer: IXITAB

© 2023 IXITAB. All rights reserved.

Related Documents - KWS-AC301, KWS-AC300

Preview KWS-DC200 DC Power Meter Instruction Manual
User manual for the KWS-DC200 series DC power meter, detailing its functions, parameters, and wiring instructions for models KWS-DC200-10A, KWS-DC200-50A, and KWS-DC200-100A.
Preview JUANJUAN KWS AC301 Digital Meter User Manual: Setup, Operation, and Troubleshooting
Comprehensive user manual for the JUANJUAN KWS AC301 digital meter. Learn how to set alarm prompts, reset power and time, view parameters, cancel alarms, and restore factory settings. Includes detailed instructions and operational guidance.
Preview KWS-302WF/L/302 Multifunctional AC Energy Meter Installation Guide and Technical Specifications
Comprehensive installation instructions and technical specifications for the KWS-302WF, KWS-302L, and KWS-302 HD colour screen multifunctional AC energy meters, covering setup, usage, and safety precautions.
Preview JUANJUAN KWS-AC301 Power Meter User Manual
User guide for setting alarm notifications, resetting power and time, viewing parameters, canceling alerts, and restoring factory settings for the JUANJUAN KWS-AC301 power meter.
Preview Návod k použití elektroměru KWS-AC301
Kompletní návod k použití a specifikace pro elektroměr KWS-AC301 a jeho varianty (KWS-AC301-20A, KWS-AC301-100A, KWS-AC301L-20A, KWS-AC301L-100A). Dokument obsahuje popis displeje, tabulku parametrů, provozní pokyny, informace o resetování a schémata zapojení.
Preview USB Type-C Tester Series: KWS-2301C, KWS-2302C, and KWS-2303C User Guide
Comprehensive user guide and technical specifications for the KWS-2301C, KWS-2302C, and KWS-2303C USB Type-C power meters. Learn about features, display types, and measurement capabilities.