Voltas Slimm 35

Voltas Slimm 35 Tower Air Cooler User Manual

Model: Slimm 35 | Brand: Voltas

1. Introduction and Overview

This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your Voltas Slimm 35 Tower Air Cooler. Please read these instructions carefully before using the appliance and retain them for future reference.

Voltas Slimm 35 Tower Air Cooler, front view

Image 1.1: Front view of the Voltas Slimm 35 Tower Air Cooler.

Video 1.1: Product overview of the Voltas Slimm 35 Tower Air Cooler.

2. Safety Instructions

To reduce the risk of fire, electric shock, or injury, always follow these basic safety precautions:

  • Ensure the power supply voltage matches the rating label on the appliance.
  • Do not operate the cooler with a damaged cord or plug. Contact qualified service personnel for repair.
  • Always unplug the cooler before filling or draining water, cleaning, or performing any maintenance.
  • Do not immerse the appliance, cord, or plug in water or other liquids.
  • Keep the cooler away from heat sources, direct sunlight, and flammable materials.
  • Place the cooler on a stable, level surface to prevent tipping.
  • Do not block air inlets or outlets. Ensure adequate space around the unit for proper airflow.
  • This appliance is for household use only. Do not use outdoors or for commercial purposes.
  • Supervise children to ensure they do not play with the appliance.

3. Package Contents

Upon unpacking, please verify that the following items are included:

  • Voltas Slimm 35 Tower Air Cooler Unit
  • User Manual

4. Setup

Follow these steps to set up your air cooler:

  1. Placement: Place the air cooler on a firm, level surface. Ensure there is sufficient space around the unit for proper air circulation. The cooler is designed for freestanding placement.
  2. Water Filling: Open the water inlet and fill the tank with clean water. The maximum capacity is 35 liters. Monitor the water level indicator to avoid overfilling. For enhanced cooling, you may add ice to the dedicated ice chamber.
  3. Power Connection: Plug the power cord into a suitable electrical outlet. Ensure the outlet matches the voltage requirements of the cooler.
  4. Mobility: The cooler is equipped with castor wheels for easy movement. Ensure the cooler is unplugged before moving it.
Dimensions of Voltas Slimm 35 Tower Air Cooler: 32 cm D x 32 cm W x 110 cm H

Image 4.1: Dimensions of the Voltas Slimm 35 Tower Air Cooler (32D x 32W x 110H cm).

5. Operating Instructions

The Voltas Slimm 35 features mechanical controls for straightforward operation.

Voltas Slimm 35 features: Ice Chamber, Dust Filter, Water Level Indicator, Castor Wheels

Image 5.1: Key features including Ice Chamber, Dust Filter, Water Level Indicator, and Castor Wheels.

Voltas Slimm 35 features: Oscillating Swing Control, Works on Inverter, Motor with Thermal Overload Protection

Image 5.2: Additional features such as Oscillating Swing Control, Inverter compatibility, and Motor with Thermal Overload Protection.

  1. Power On/Off: Use the main power knob to turn the cooler on or off.
  2. Speed Control: Select your desired fan speed using the speed control knob. Options include High, Medium, and Low.
  3. Swing Function: Activate the auto swing louvers for wider air distribution across the room.
  4. Cooling Function: Ensure the water tank is filled for the cooling function to operate effectively. The honeycomb cooling pads facilitate efficient evaporation.
  5. Ice Chamber: For enhanced cooling, add ice cubes to the ice chamber. This helps to lower the water temperature and provide cooler air.
Voltas Slimm 35 showing three cooling modes: High, Medium, Low

Image 5.3: Illustration of the three cooling modes: High, Medium, and Low.

6. Maintenance

Regular maintenance ensures optimal performance and longevity of your air cooler.

  • Cleaning the Water Tank: Periodically drain and clean the water tank to prevent algae growth and maintain hygiene. Unplug the cooler before draining.
  • Cleaning Honeycomb Pads: The honeycomb cooling pads should be cleaned regularly. Refer to the specific instructions in the full user manual for removal and cleaning procedures. Ensure they are dry before reinstallation.
  • Cleaning the Dust Filter: The integrated dust filter captures airborne particles. Clean the filter regularly by rinsing it under running water. Allow it to dry completely before placing it back into the unit.
  • Exterior Cleaning: Wipe the exterior surfaces of the cooler with a soft, damp cloth. Do not use abrasive cleaners or solvents.

7. Troubleshooting

If you encounter issues with your air cooler, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Cooler does not turn onNo power supply; Power cord not plugged in; Fuse blownCheck power outlet; Ensure cord is securely plugged in; Check household fuse/circuit breaker
No cooling effectWater tank empty; Cooling pads dry; Pump malfunctionFill water tank; Ensure water pump is operating; Contact service if pump is faulty
Weak airflowAir inlets/outlets blocked; Dust filter clogged; Fan speed set too lowClear obstructions; Clean dust filter; Increase fan speed
Unpleasant odorStagnant water; Dirty cooling padsDrain and clean water tank; Clean or replace cooling pads

If the problem persists after attempting these solutions, please contact Voltas customer support.

8. Specifications

Key technical specifications for the Voltas Slimm 35 Tower Air Cooler:

FeatureSpecification
BrandVoltas
Model NameSlimm 35
Model Number4810358
TypeTower Air Cooler
Tank Capacity35 Liters
Air Throw7.5 meters
Air Flow950 CMH
Area Coverage19 sq. meters
Cooling MediaHoneycomb Pads
Operation ModeMechanical
Number of Speeds3 (High/Medium/Low)
Special FeatureAuto Restart, Auto Swing Louvers, Ice Chamber, Dust Filter, Works on Inverter, Motor with Thermal Overload Protection
Water Level IndicatorYes
Mounting TypeFreestanding
MaterialPlastic
ColorWhite
Item Weight12 Kilograms
Item Dimensions (D x W x H)32D x 32W x 110H Centimeters
Voltas Slimm 35 showing 19 sq.m coverage, 7.5m air throw, 950 CMH air delivery, and honeycomb cooling pad

Image 8.1: Cooling performance metrics and honeycomb pad detail.

9. Warranty and Support

Your Voltas Slimm 35 Tower Air Cooler comes with a 1-year product warranty from the date of purchase. Please retain your purchase receipt as proof of warranty.

For warranty claims, technical assistance, or any other inquiries, please contact Voltas customer support. Refer to the contact information provided in your warranty card or visit the official Voltas website.

© 2024 Voltas. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.