Jesverty HK33D

Jesverty HK33D Digital Multimeter User Manual

Model: HK33D

1. Introduction

The Jesverty HK33D is a versatile 2000-count digital multimeter designed for accurate measurement of various electrical parameters. This instrument is suitable for both industrial and household electrical troubleshooting, including testing household outlets, fuses, batteries, and automotive circuits. It measures AC/DC Voltage, DC Current, Resistance, and performs Diode and Continuity tests. Additionally, it features Live Wire detection, Non-Contact Voltage (NCV) detection, and Temperature measurement capabilities.

Jesverty HK33D Digital Multimeter in various application scenarios

Image: The Jesverty HK33D Digital Multimeter being used for various electrical measurements, including circuit board testing, fuse checking, and automotive diagnostics.

2. Safety Information

To ensure safe operation and avoid damage to the meter, please read and follow all safety instructions carefully. This device is rated for CAT III 600V.

  • Always ensure the test leads are properly connected and the function dial is set to the correct range before making any measurements.
  • Never exceed the maximum input values specified for each range.
  • Do not use the meter if it or the test leads appear damaged. Inspect them before each use.
  • Turn off power to the circuit under test before connecting or disconnecting test leads, especially when measuring current.
  • Be cautious when working with voltages above 30V AC RMS, 42V peak, or 60V DC, as these pose a shock hazard.
  • Replace batteries promptly when the low battery indicator appears to ensure accurate readings.
  • Do not operate the meter in explosive gas, vapor, or dust environments.

3. Product Overview and Features

The Jesverty HK33D Digital Multimeter is designed for ease of use and reliability. It features a clear LCD screen, a rotary function dial, and dedicated buttons for various operations.

Jesverty HK33D Digital Multimeter with test leads and accessories

Image: The Jesverty HK33D Digital Multimeter, showing its orange casing, LCD display, function dial, input jacks, test leads, and included batteries.

Key Features:

  • 2000 Counts Digital Display: Provides clear and precise readings.
  • True RMS Measurement: Ensures accurate readings for non-sinusoidal waveforms.
  • Versatile Measurement Functions: Measures AC/DC Voltage, DC Current, Resistance, Diode, Continuity, Frequency, Duty Cycle, and hFE.
  • Live Wire Detection: Identifies live electrical wires.
  • Non-Contact Voltage (NCV) Function: Detects AC voltage without direct contact, enhancing safety.
  • Temperature Measurement: Includes a K-Type thermocouple for temperature readings.
  • Audible Assurance: Built-in buzzer for continuity tests (sounds if resistance is less than 50Ω).
  • Backlight LCD Screen: Improves visibility in low-light conditions.
  • LED Flashlight: Assists in illuminating dark work areas.
  • Support Stand: Flexible and stable stand for convenient hands-free operation, adjustable up to 90 degrees.
  • Overload Protection: Equipped with 2 stable fuses to provide safety and overload protection on all ranges.
Jesverty HK33D Digital Multimeter display and functions

Image: Close-up of the Jesverty HK33D multimeter display, highlighting its 2000 counts and various measurement modes like DC Voltage, Live, NCV, Frequency, AC Voltage, Duty Cycle, Diode, Resistance, hFE, Continuity, Temperature, and Microampere.

Internal view of Jesverty HK33D Multimeter with chipset and fuses

Image: An internal view of the Jesverty HK33D Digital Multimeter, illustrating its high-performance chipset for accurate measurements and two stable fuses for overload protection across all ranges.

Jesverty HK33D Multimeter features: Audible, NCV, Temperature, Stand

Image: Four panels demonstrating key features: Audible Assurance (buzzer for continuity), NCV Function (non-contact live wire detection), Temperature Measurement (using K-Type thermocouple), and the flexible Support Stand.

Jesverty HK33D Multimeter with LED flashlight in use

Image: The Jesverty HK33D Digital Multimeter's LED flashlight illuminating a dark electrical panel, demonstrating how the backlight and flashlight work together for safer measurements in low-light conditions.

4. Setup

4.1 Unpacking

Carefully unpack the contents of the box. The package should include:

  • Jesverty HK33D Digital Multimeter
  • Set of Test Leads (Red and Black)
  • K-Type Thermocouple (for temperature measurement)
  • User Manual
Contents of the Jesverty HK33D Multimeter package

Image: The complete package contents of the Jesverty HK33D Digital Multimeter, including the multimeter, test leads, K-type thermocouple, and user manual.

4.2 Battery Installation

The Jesverty HK33D Multimeter requires batteries for operation (batteries are not included in the package). To install or replace batteries:

  1. Ensure the multimeter is turned OFF.
  2. Locate the battery compartment cover on the back of the unit.
  3. Use a screwdriver to open the battery compartment.
  4. Insert the required batteries, observing the correct polarity (+ and -).
  5. Replace the battery compartment cover and secure it with the screw.

4.3 Test Lead Connection

Connect the test leads to the appropriate input jacks on the multimeter:

  • Connect the black test lead to the COM (Common) jack.
  • For most measurements (Voltage, Resistance, Diode, Continuity, Frequency, Temperature, small Current), connect the red test lead to the VΩmA jack.
  • For large current measurements (up to 10A), connect the red test lead to the 10A MAX jack.

5. Operating Instructions

Before operating, ensure the multimeter is set up correctly as described in Section 4.

5.1 Function Selection

Rotate the central dial to select the desired measurement function. The display will show the corresponding symbol for the selected mode.

5.2 Measuring AC/DC Voltage

  1. Connect the black test lead to COM and the red test lead to VΩmA.
  2. Turn the rotary dial to the V~ (AC Voltage) or V- (DC Voltage) position.
  3. Connect the test probes in parallel to the circuit or component you wish to measure.
  4. Read the voltage value on the display.
Jesverty HK33D Multimeter AC/DC Voltage Testing

Image: The Jesverty HK33D Multimeter performing DC Voltage measurement on a battery and AC Voltage measurement on a power supply, illustrating proper test lead connection and display readings.

5.3 Measuring DC Current

  1. Important: Turn off power to the circuit before connecting the multimeter.
  2. Connect the black test lead to COM. Connect the red test lead to VΩmA for mA range or 10A MAX for A range.
  3. Turn the rotary dial to the A- (DC Current) or mA- (DC Milliamperes) position.
  4. Break the circuit and connect the multimeter in series with the load.
  5. Turn on the circuit power and read the current value on the display.
  6. Turn off power before disconnecting the multimeter and restoring the circuit.

5.4 Measuring Resistance

  1. Ensure the circuit is de-energized and any capacitors are discharged.
  2. Connect the black test lead to COM and the red test lead to VΩmA.
  3. Turn the rotary dial to the Ω (Resistance) position.
  4. Connect the test probes across the component to measure its resistance.
  5. Read the resistance value on the display.

5.5 Continuity Test

  1. Ensure the circuit is de-energized.
  2. Connect the black test lead to COM and the red test lead to VΩmA.
  3. Turn the rotary dial to the Continuity (speaker icon) position.
  4. Touch the test probes to the two points you want to check for continuity.
  5. If there is continuity (resistance less than approximately 50Ω), the buzzer will sound.

5.6 Diode Test

  1. Ensure the circuit is de-energized.
  2. Connect the black test lead to COM and the red test lead to VΩmA.
  3. Turn the rotary dial to the Diode (diode symbol) position.
  4. Connect the red probe to the anode and the black probe to the cathode of the diode.
  5. The display will show the forward voltage drop. Reverse the probes; the display should show 'OL' (Open Line) for a good diode.

5.7 Non-Contact Voltage (NCV) Detection

  1. Turn the rotary dial to the NCV position.
  2. Move the top end of the multimeter near the conductor or outlet you want to test.
  3. The meter will beep and the LED will flash with increasing frequency as it detects AC voltage.

5.8 Live Wire Test

  1. Turn the rotary dial to the Live position.
  2. Insert the red test probe into the live terminal of an outlet or touch it to a live wire.
  3. The display will indicate 'LIVE' and the meter will beep if a live wire is detected.

5.9 Temperature Measurement

  1. Connect the K-Type thermocouple to the VΩmA and COM jacks, observing polarity.
  2. Turn the rotary dial to the °C/°F position.
  3. Place the thermocouple tip on or in the object whose temperature you wish to measure.
  4. Read the temperature value on the display. Use the 'SEL' button to switch between Celsius and Fahrenheit.

5.10 Frequency (Hz) and Duty Cycle (%)

  1. Connect the black test lead to COM and the red test lead to VΩmA.
  2. Turn the rotary dial to the Hz/% position.
  3. Connect the test probes to the signal source.
  4. Read the frequency or duty cycle on the display. Use the 'SEL' button to toggle between Hz and %.

5.11 hFE (Transistor Test)

This function allows for testing the DC current gain (hFE) of NPN and PNP transistors. Refer to the specific markings on the multimeter for transistor lead insertion points (E, B, C for Emitter, Base, Collector).

  1. Turn the rotary dial to the hFE position.
  2. Insert the transistor leads into the corresponding sockets on the multimeter.
  3. Read the hFE value on the display.

5.12 Additional Functions (Buttons)

  • SEL Button: Used to switch between different functions within a single dial position (e.g., AC/DC, Hz/%, °C/°F).
  • H / ★ Button: Short press for Data Hold (H), which freezes the current reading on the display. Long press for Backlight (★), which illuminates the LCD.
  • MIN MAX REL Button: Used to record minimum/maximum values or for relative measurement.

6. Maintenance

6.1 Cleaning

Wipe the meter with a damp cloth and mild detergent. Do not use abrasives or solvents. Ensure the meter is dry before use.

6.2 Battery Replacement

When the low battery indicator appears on the display, replace the batteries as described in Section 4.2 to maintain measurement accuracy.

6.3 Fuse Replacement

If the current measurement function stops working, the fuse may need replacement. Refer to the specifications for the correct fuse type and rating. Fuse replacement should only be performed by qualified personnel.

6.4 Storage

If the meter is not used for an extended period, remove the batteries to prevent leakage and store it in a cool, dry place away from direct sunlight.

7. Troubleshooting

If you encounter issues with your Jesverty HK33D Multimeter, refer to the following common troubleshooting steps:

  • No Display or Faint Display: Check battery installation and replace batteries if necessary.
  • Incorrect Readings: Ensure the function dial is set to the correct measurement type and range. Check test lead connections. Verify the circuit is de-energized for resistance/continuity tests.
  • Current Measurement Not Working: Check if the fuse is blown. Replace if needed (refer to Section 6.3).
  • Continuity Buzzer Not Sounding: Ensure the resistance between the probes is below 50Ω. Check test leads for damage.
  • NCV/Live Wire Detection Not Working: Ensure the function is selected correctly. The presence of strong electromagnetic fields can interfere with these functions.

If the problem persists after attempting these steps, contact customer support.

8. Specifications

ParameterValue
BrandJesverty
Model NumberHK33D (also referred to as HS33D)
Display2000 Counts Digital LCD
Power SourceBattery Powered (Batteries not included)
Safety RatingCAT III 600V
Item Weight340 g
Package Dimensions17.09 x 11.2 x 5.41 cm
Included ComponentsMultimeter, Test Leads, User Manual, K-Type Thermocouple
UPC680306174911

9. Warranty and Support

For warranty information or technical support, please refer to the contact details provided with your purchase or visit the official Jesverty website. Keep your purchase receipt as proof of purchase for any warranty claims.

Related Documents - HK33D

Preview HK33D Compact Digital Multimeter User Manual - Operation and Specifications
Comprehensive user manual for the HK33D Compact Digital Multimeter, detailing its features, specifications, safety information, and instructions for various measurements including voltage, current, resistance, and more.
Preview Jesverty SPS-3020H DC Strømforsyning Brugervejledning
Brugervejledning og tekniske specifikationer for Jesverty SPS-3020H DC strømforsyning. Lær om opsætning, sikkerhedsinstruktioner og drift af denne 0-30V, 0-20A laboratoriestrømforsyning.
Preview JESVERTY SPS-3010X DC Power Supply User Manual
User manual for the JESVERTY SPS-3010X 300W DC Power Supply, detailing its specifications, panel instructions, safety precautions, and operational functions including constant voltage/current characteristics and fuse replacement.
Preview Jesverty SPS-1362 Adjustable DC Power Supply - User Manual and Specifications
Comprehensive user manual and technical specifications for the Jesverty SPS-1362 60A adjustable DC power supply. Includes safety warnings, operational controls, detailed technical data, and troubleshooting guidance.
Preview JESVERTY SPS Series Switching Power Supply User Manual
Comprehensive user manual for JESVERTY SPS series switching power supplies, detailing operation, technical specifications, safety notices, and control panel functions. Covers models SPS1540H/HP through SPS10010H/HP.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.