LANCHEZ Q800167-1

LANCHEZ 1HP 6600 GPH Submersible Sewage Pump User Manual

Model: Q800167-1

1. Introduction

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your LANCHEZ 1HP 6600 GPH Submersible Sewage Pump. This heavy-duty cast iron effluent pump is designed for various applications including sump basins, basements, residential sewage systems, and dewatering tasks. It features a powerful 1HP motor, a maximum flow rate of 6600 gallons per hour (GPH), and an automatic tethered float switch for reliable performance.

Please read this manual thoroughly before installation and operation to ensure proper use and to prevent potential hazards.

LANCHEZ 1HP 6600 GPH Submersible Sewage Pump

Figure 1: LANCHEZ 1HP 6600 GPH Submersible Sewage Pump

2. Safety Information

Always observe basic safety precautions to reduce the risk of fire, electric shock, and personal injury.

  • Electrical Safety: Ensure the pump is connected to a properly grounded 115V AC outlet. Do not modify the plug. Do not operate the pump with a damaged cord or plug.
  • Submersible Use Only: This pump is designed for submersible applications. Do not operate it dry, as this can cause motor damage and activate the built-in thermal overload protection.
  • Handling: Never lift or carry the pump by its power cord or float switch cable. Use the integrated handle or a rope attached to the designated pull ring.
  • Water Temperature: Do not use the pump with water temperatures exceeding 95°F (35°C).
  • Hazardous Materials: Do not use the pump to handle flammable, corrosive, or explosive liquids.
  • Maintenance: Always disconnect power before performing any maintenance or cleaning on the pump.

3. Product Features

  • Powerful 1HP Motor: Equipped with an efficient PSC copper motor for strong flow and quiet operation.
  • Heavy-Duty Cast Iron Construction: Provides corrosion resistance, enhanced durability, and improved heat dissipation for extended life.
  • Automatic Tethered Float Switch: Automatically turns the pump ON and OFF based on water levels, preventing dry running and ensuring efficient operation.
  • Non-Clog Vortex Impeller: Designed to handle solids up to 2 inches in diameter without clogging, suitable for sewage and effluent applications.
  • 2-inch NPT Discharge: Large discharge port for high-capacity pumping.
  • Thermal Overload Protection: Built-in safety feature to prevent motor burnout in case of overheating or dry running.
  • 10ft Grounded Power Cord: Extended length for flexible installation and safety.
Technical parameters of LANCHEZ sewage pump including max head, flow rate, outlet size, power cord length, noise level, and waterproof rating.

Figure 2: Technical Parameters Overview

Diagram showing internal components of the LANCHEZ sewage pump including heavy-duty cast iron housing, copper wire motor, non-clog vortex impeller, piggyback tether float switch, and oil-filled construction.

Figure 3: Product Internal Components Diagram

4. Technical Specifications

SpecificationValue
BrandLANCHEZ
Model NumberQ800167-1
Horsepower1 HP
Maximum Flow Rate6600 GPH (94.07 GPM)
Maximum Lifting Height27 Feet
Voltage115 Volts (AC)
Wattage800 Watt-hours
MaterialCast Iron
Product Dimensions (L x W x H)6.06" x 9.05" x 15.7"
Item Weight24.9 pounds
Cord Length10 Feet
Discharge Size2" NPT
Waterproof RatingIPX8
Included ComponentsPiggy Back Tether Float Switch, Sewage Pump
Detailed technical specifications of the LANCHEZ sewage pump including horsepower, max flow rate, discharge, waterproof rating, max head, power cord length, low noise, water temperature, and voltage/frequency.

Figure 4: Detailed Technical Specifications

Graph showing the output flow rate at various total head heights for the LANCHEZ sewage pump, from 6600 GPH at 0 ft to 300 GPH at 25 ft.

Figure 5: Output Flow Rate vs. Total Head Performance Curve

5. Setup and Installation

Follow these steps for proper installation of your submersible sewage pump:

  1. Placement: Position the pump on a stable, level surface within the sump basin, sewage well, or other application area. Ensure the pump is placed at the bottom and is not obstructed.
  2. Discharge Pipe Connection: Connect a properly sized water hose or rigid pipe (2-inch NPT) to the pump's discharge port. Ensure all connections are secure and watertight.
  3. Float Switch Adjustment: The pump comes with a piggyback tethered float switch. The float switch determines the automatic ON/OFF levels. Adjust the tether length to set the desired operating range. The pump will turn ON when the water level reaches approximately 15.7 inches and turn OFF when it drops to about 9.8 inches.
  4. Power Connection: Plug the pump's power cord into a grounded 115V AC electrical outlet. For automatic operation, ensure the float switch plug is connected to the main power plug (piggyback configuration). For manual operation, the float switch plug can be bypassed by plugging the main power cord directly into the outlet.
  5. Secure Lifting: When lowering or raising the pump, always use the integrated pull ring or a sturdy rope. Never lift the pump by its power cord or float switch cable.
Operating instructions showing three steps: 1. Connect a properly sized water hose (2 inch NPT). 2. Put the pump into the water, paying attention to the bottom to be placed firmly. 3. Auto Mode: Connect the power cord with the float switch wire. Manual Mode: Directly plug the power cord into the socket.

Figure 6: Installation Steps Overview

Diagram illustrating the pump's automatic operation with water levels. The pump turns ON at 15.7 inches and OFF at 9.8 inches. It also shows various types of solids the pump can handle, such as sand, fine fiber, hair, gravel, and food residue.

Figure 7: Automatic Water Level Operation and Handled Solids

6. Operating Instructions

The LANCHEZ sewage pump offers two operating modes:

  • Automatic Mode: This is the recommended mode for most applications. With the piggyback float switch properly connected and adjusted, the pump will automatically activate when the water level rises to approximately 15.7 inches and deactivate when the water level drops to about 9.8 inches. This prevents dry running and ensures efficient water removal.
  • Manual Mode: For continuous operation, the float switch can be bypassed by plugging the pump's main power cord directly into the electrical outlet. In manual mode, the pump will run continuously until unplugged. Caution: Do not operate the pump in manual mode without constant supervision to prevent dry running, which can damage the motor.
Two images showing the automatic float switch operation. One image shows the pump stopping when the water level is OFF at 9.84 inches, and the other shows it starting when the water level is ON at 15.75 inches.

Figure 8: Automatic Float Switch Operation

Image showing the piggy-back float switch plug for auto and manual modes, and a close-up of the large 2 inch NPT discharge.

Figure 9: Piggy-Back Float Switch and Discharge

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your pump. Always disconnect the pump from the power source before performing any maintenance.

  • Regular Inspection: Periodically inspect the pump for any visible damage, especially to the power cord and float switch cable.
  • Impeller Cleaning: If the pump's performance decreases, the non-clog vortex impeller may have accumulated debris. Carefully remove the pump from the basin and inspect the impeller area for obstructions. Clear any debris gently.
  • Float Switch Check: Ensure the float switch moves freely and is not obstructed by debris or the basin walls.
  • Discharge Pipe: Check the discharge pipe for any blockages or leaks.
  • Winterization (if applicable): If the pump is used in an area subject to freezing temperatures and will not be in use, remove it from the water, clean it thoroughly, and store it in a dry, frost-free location.

8. Troubleshooting

Refer to the following table for common issues and their solutions:

ProblemPossible CauseSolution
Pump does not startNo power; Float switch stuck; Impeller jammed; Thermal overload activatedCheck power supply and circuit breaker; Ensure float switch moves freely; Clear impeller of debris; Allow pump to cool down if thermal overload tripped.
Pump runs continuouslyFloat switch stuck in ON position; Pump in manual modeCheck float switch for obstructions; Ensure pump is in automatic mode (piggyback plug connected).
Reduced flow or no water pumpedDischarge pipe blocked; Impeller partially clogged; Air lock; Low water levelCheck and clear discharge pipe; Clean impeller; Ensure pump is fully submerged and free of air pockets; Verify water level is above the ON threshold.
Pump makes unusual noiseDebris in impeller; Worn bearingsDisconnect power and clear impeller; If noise persists, contact customer support.

9. Warranty and Customer Support

LANCHEZ stands behind the quality of its products. This pump comes with a 3-year worry-free manufacturer after-service and 3 years of technical support.

If you encounter any issues or have questions regarding your LANCHEZ 1HP 6600 GPH Submersible Sewage Pump, please do not hesitate to contact our customer support team. We offer 24-hour customer support to assist you.

For assistance, please refer to the contact information provided with your purchase or visit the official LANCHEZ website.

© 2025 LANCHEZ. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.