1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Cooper & Hunter Olivia Series 6,000 BTU 115V 23 SEER2 Single Zone Mini Split AC/Heating Ductless Inverter System. Please read this manual thoroughly before installation and use, and retain it for future reference.
The Cooper & Hunter Olivia Series is designed to provide both cooling and heating functions, featuring inverter technology for energy efficiency and quiet operation. This system includes an indoor wall-mount unit and an outdoor condenser unit.

Image 1.1: Overview of the Cooper & Hunter Olivia Series Mini Split System, showing the indoor unit, outdoor unit, remote control, and various installation kit components.
2. Safety Information
Important: This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- Professional Installation Required: This is not DIY equipment. Professional installation is required to ensure proper function, safety, and warranty validity. Improper installation can lead to electric shock, fire, serious injury, or death.
- Electrical Safety: Ensure the power supply matches the unit's specifications (115V, 1Ph, 60Hz). All electrical work must comply with local and national electrical codes.
- Refrigerant Handling: The system uses R410A refrigerant. Handling of refrigerant should only be performed by certified technicians.
- Maintenance: Disconnect power before performing any maintenance or cleaning.
- Location: Install the outdoor unit in a location that allows for proper airflow and drainage, away from flammable materials.
3. Product Components
Your Cooper & Hunter Olivia Series Mini Split System includes the following main components:
- Indoor Wall Mount Air Handler (Model: CH-06OLVWM-115VI) with Remote Control
- Outdoor Condenser Unit (Model: CH-ES06-115VO)
- Installation Kit:
- 16ft Pre-Flared and Insulated Copper Line Sets
- Communication Wires
- Small Accessories
- 16ft Drainage Extension
- Smart Port Adapter (for Wi-Fi control)

Image 3.1: Detailed view of the components included with your order, illustrating the indoor unit, outdoor unit, remote, pre-flared copper line set, communication wires, and drainage extension.

Image 3.2: Illustration of the included no-kink drainage extension, featuring rubberized hose with plastic coil inserts for improved durability and function compared to standard plastic hoses.

Image 3.3: Comparison highlighting the UV & UV-C protected insulation used in the system's line sets, demonstrating its resistance to degradation compared to regular insulation.
4. Setup and Installation
Warning: Installation of this mini split system requires specialized tools and knowledge. Professional installation is mandatory to ensure safety, optimal performance, and to maintain the product warranty. Attempting self-installation without proper qualifications may result in electric shock, fire, property damage, serious injury, or death, and will void the warranty.
4.1 Pre-Installation Checks
- Verify that the power supply voltage and frequency match the unit's requirements (115V, 1Ph, 60Hz).
- Ensure the installation location for both indoor and outdoor units provides adequate space for airflow and maintenance.
- Confirm that the wall structure can support the weight of the indoor unit.
4.2 Installation Process (Overview for Professionals)
A qualified HVAC technician will typically follow these steps:
- Indoor Unit Installation: Mount the indoor unit on the wall using the provided template, ensuring proper drainage slope.
- Outdoor Unit Installation: Securely place the outdoor condenser unit on a level surface or wall bracket, ensuring sufficient clearance.
- Line Set Connection: Connect the pre-flared copper line sets between the indoor and outdoor units. This involves proper torqueing and leak checking.
- Electrical Wiring: Connect the communication wires and power supply wiring according to the wiring diagram. Ensure all connections are secure and properly insulated.
- Vacuuming and Refrigerant Release: Evacuate the line sets and indoor unit to remove air and moisture. Once a proper vacuum is achieved, release the pre-charged R410A refrigerant from the outdoor unit into the system.
- Drainage Connection: Connect the drainage hose from the indoor unit to an appropriate drain point, ensuring a continuous downward slope.
- Test Run: Perform a test run to verify proper operation in both cooling and heating modes, check for leaks, and confirm correct temperature output.
For detailed installation instructions, refer to the separate installation manual provided with the product, intended for certified technicians.
5. Operating Instructions
Your Cooper & Hunter Olivia Series Mini Split System can be operated using the included remote control or via the C&H Remote app with the smart port adapter.
5.1 Remote Control Operation
The remote control allows you to adjust settings such as mode, temperature, fan speed, and timer functions. Point the remote control directly at the indoor unit when making adjustments.
- Power Button: Turns the unit ON or OFF.
- Mode Button: Cycles through operating modes: Auto, Cool, Dry (Dehumidifier), Heat, Fan.
- Temperature Adjustment: Use the Up/Down arrows to set the desired temperature.
- Fan Speed: Adjusts the fan speed (Auto, Low, Medium, High).
- Swing Button: Controls the louver movement for air direction.
- Timer Function: Set the unit to turn ON or OFF automatically after a specified period.
5.2 Wi-Fi Smart Control (C&H Remote App)
The smart port adapter enables control of your mini-split system from your smartphone using the C&H Remote app. This allows for remote operation and scheduling.
- Install Smart Port Adapter: Follow the instructions provided with the smart port adapter to connect it to your indoor unit.
- Download App: Download the "C&H Remote" app from your smartphone's app store.
- Pair Device: Follow the in-app instructions to pair your mini-split system with your smartphone.
- Control: Once paired, you can control all functions of the unit, including mode, temperature, fan speed, and scheduling, from anywhere with an internet connection.

Image 5.1: The Olivia Series indoor unit, showcasing control options via the physical remote and the C&H Remote smartphone application.
5.3 Key Operating Features
- Inverter Compressor: Provides variable speed operation for precise temperature control, reduced energy consumption, and quieter performance.
- Whisper Technology: Designed for quiet operation, making it suitable for bedrooms and living areas (Noise level: 24 dB).
- Dehumidifier Function: Reduces humidity levels in the room.
- Heating Function: Operates effectively in ambient temperatures down to -13°F.
- Auto-Swing Louvers: Distributes air evenly throughout the room.
- Turbo Mode: Quickly reaches the desired temperature.
- Eco Mode: Optimizes operation for maximum energy savings.
- Self-Cleaning Function: Helps prevent mold and mildew buildup on the indoor coil.
6. Maintenance
Regular maintenance ensures the longevity and efficient operation of your mini split system. Always disconnect power to the unit before performing any maintenance.
6.1 Air Filter Cleaning
- Frequency: Clean air filters every two weeks or more frequently depending on usage and air quality.
- Procedure:
- Open the front panel of the indoor unit.
- Remove the air filters.
- Clean filters with a vacuum cleaner or wash them with lukewarm water.
- Allow filters to dry completely before reinstalling.
- Close the front panel.
6.2 Outdoor Unit Cleaning
- Frequency: Inspect and clean the outdoor unit coils and fan blades annually, or as needed.
- Procedure:
- Ensure power is disconnected.
- Remove any debris (leaves, dirt, etc.) from around the outdoor unit.
- Carefully clean the condenser coils with a soft brush or water hose. Avoid bending the fins.
- Ensure the drainage outlet is clear.
6.3 Professional Servicing
It is recommended to have a qualified HVAC technician perform a comprehensive service check annually. This includes checking refrigerant levels, electrical connections, and overall system performance.
7. Troubleshooting
Before contacting customer support, review the following common issues and solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on | No power, circuit breaker tripped, remote batteries low. | Check power supply, reset breaker, replace remote batteries. |
| Insufficient cooling/heating | Dirty air filters, blocked outdoor unit, incorrect mode/temperature setting, low refrigerant. | Clean air filters, clear obstructions from outdoor unit, verify settings, contact technician for refrigerant check. |
| Water leakage from indoor unit | Blocked drainage hose, improper installation. | Check and clear drainage hose, contact technician for inspection. |
| Unusual noise | Loose parts, fan obstruction, compressor issue. | Inspect for loose parts, clear obstructions, contact technician. |
| Wi-Fi connection issues | Router issues, incorrect app settings, smart port adapter not properly installed. | Restart router, reconfigure app settings, check smart port adapter connection. |
If the problem persists after attempting these solutions, please contact Cooper & Hunter customer support or a qualified service technician.
8. Specifications
| Feature | Detail |
|---|---|
| Brand | Cooper & Hunter |
| Model (System) | CH-06OLVWM-115VO/I |
| Cooling Capacity | 6,000 BTU |
| Voltage | 115 Volts |
| Phase | 1 Ph |
| Frequency | 60 Hz |
| SEER2 Rating | 23.00 |
| Noise Level (Indoor) | 24 dB |
| Refrigerant Type | R410A |
| Special Features | Dehumidifier, Heating And Cooling Function, Inverter Compressor, Remote Controlled, WiFi Enabled |
| Dimensions (Shipping) | 48 x 40 x 40 inches |
| Weight (Shipping) | 107.8 pounds |

Image 8.1: EnergyGuide label for the Cooper & Hunter Olivia Series, detailing the Cooling Efficiency Rating (SEER2) and Heating Efficiency Rating (HSPF2).
9. Warranty and Support
Cooper & Hunter is committed to providing high-quality HVAC solutions. For warranty details, please refer to the warranty card included with your product or visit the official Cooper & Hunter website.
Customer Support: U.S.-based experienced technicians are available to provide assistance as needed. Cooper & Hunter offers dedicated support in English, Spanish, Mandarin, Russian, and Ukrainian, available Monday-Friday, 9 AM to 5 PM.
For technical support or service inquiries, please contact Cooper & Hunter directly through their official channels.