1. Introduction
The DEWIN AC220V Automatic Voltage Protection Plug is designed to safeguard your electrical appliances from damage caused by voltage fluctuations, including overvoltage, undervoltage, and overcurrent conditions. This device features adjustable voltage settings and an intuitive LCD display for monitoring and control. Its plug-and-play design ensures easy installation and use, making it suitable for a wide range of household appliances.

Figure 1: DEWIN Automatic Voltage Protection Plug with LED display.
2. Safety Information
Please read all safety instructions before using the device. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Ensure the device is used with a compatible AC220V power supply.
- Do not disassemble or modify the device.
- Keep out of reach of children. The safety socket is designed to prevent accidental contact by inserting fingers or small objects.
- Avoid exposing the device to water or excessive humidity.
- If the device appears damaged, do not use it.
- Always unplug the device from the wall socket before cleaning or if it will be unused for an extended period.

Figure 2: Safety socket design to prevent accidental insertion.
3. Product Overview
The DEWIN Voltage Protection Plug features a clear LCD display and user-friendly controls for easy operation.

Figure 3: Product components and display indicators.
Key Features:
- Adjustable Voltage Protection: Customize overvoltage (230-300V, default 270V) and undervoltage (140-210V, default 170V) thresholds.
- LCD Display: Provides clear, real-time indication of voltage and current status.
- Integrated 16A Magnetic Relay: Ensures immediate power cutoff during voltage anomalies to protect connected appliances.
- Plug-and-Play Design: Simple and quick installation.
- Wide Application: Suitable for refrigerators, air conditioners, water heaters, rice cookers, washing machines, televisions, and other electrical appliances.
- Voltage Correction: Allows for voltage calibration between -20V and 20V if the displayed voltage is inaccurate.
4. Setup
The DEWIN Voltage Protection Plug is designed for easy plug-and-play installation.
- Unpack: Carefully remove the voltage protection plug from its packaging.
- Inspect: Check the device for any visible damage. Do not use if damaged.
- Plug In: Insert the DEWIN Voltage Protection Plug directly into a standard AC220V wall socket.
- Connect Appliance: Plug your electrical appliance (e.g., refrigerator, TV) into the socket on the front of the voltage protection plug.
- Power On: Ensure the appliance is switched on. The LCD display on the protection plug will show the current voltage and current.

Figure 4: Examples of appliance connections.
5. Operating Instructions
The device operates automatically to protect your appliances. You can also adjust its settings.
5.1. Monitoring Display
- The LCD screen continuously displays the current voltage (V) and current (A) of the connected appliance.
- Indicators for overvoltage (>V), undervoltage (<V), and overcurrent (>A) will illuminate if these conditions are detected.
- The "POWER" indicator shows if the device is supplying power.
5.2. Adjusting Settings
To adjust the overvoltage, undervoltage, or current limits:
- Enter Setting Mode: Press the SET button. The display will start flashing, indicating you are in setting mode.
- Select Parameter: Use the Up (▲) or Down (▼) adjustment keys to cycle through the adjustable parameters: overvoltage limit, undervoltage limit, and overcurrent limit.
- Adjust Value: Once the desired parameter is flashing, use the Up (▲) or Down (▼) keys to increase or decrease the value.
- Confirm Setting: Press the SET button again to confirm the adjusted value and move to the next parameter, or wait a few seconds for the device to automatically save the setting and exit setting mode.
Default Settings:
- Overvoltage Protection: 270V (Adjustable: 230V - 300V)
- Undervoltage Protection: 170V (Adjustable: 140V - 210V)
- Overcurrent Range: 1A - 16A
5.3. Voltage Correction
If the displayed voltage is inaccurate, it can be corrected within a range of -20V to +20V. Refer to the detailed instructions in the full product manual for specific steps on voltage calibration.
5.4. Recovery Delay Time
After a voltage anomaly, the device has a recovery delay time (1-500 seconds) before restoring power to the appliance. This delay protects sensitive electronics from rapid power cycling.
6. Maintenance
The DEWIN Voltage Protection Plug requires minimal maintenance.
- Cleaning: Disconnect the device from the power outlet before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners or abrasive materials.
- Storage: If not in use for an extended period, store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- Inspection: Periodically inspect the device for any signs of wear or damage, especially the plug pins and socket.
7. Troubleshooting
If you encounter issues with your DEWIN Voltage Protection Plug, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Device not powering on / LCD display is off. | No power from wall socket, device malfunction. | Check if the wall socket is live by plugging in another device. Ensure the plug is fully inserted. If still off, the device may be faulty. |
| Appliance not receiving power. | Voltage/current outside set limits, recovery delay active, appliance fault. | Check the LCD display for overvoltage/undervoltage/overcurrent indicators. Wait for the recovery delay to complete. Test the appliance by plugging it directly into a wall socket. |
| Inaccurate voltage reading on LCD. | Calibration needed. | Perform voltage correction as described in section 5.3. |
| Settings cannot be changed. | Not in setting mode, buttons unresponsive. | Press and hold the SET button to enter setting mode. If buttons are unresponsive, try unplugging and re-plugging the device. |
If the problem persists after attempting these solutions, please contact DEWIN customer support.
8. Specifications
| Parameter | Value |
|---|---|
| Product Name | Over and Under Voltage Socket |
| Model Number | IXRAQCCRI-GS109785 |
| Material | Polycarbonate (PC) |
| Socket Specification | European Standard |
| Rated Voltage | 220V AC |
| Rated Current | 16 A |
| Overvoltage Range | 230-300 V (Standard: 270 V) |
| Undervoltage Range | 140-210 V (Standard: 170 V) |
| Current Range | 1-16 A |
| Recovery Delay Time | 1-500 s |
| Power Consumption | ≤ 2 W |
| Dimensions | 12.5 x 5.7 x 4.8 cm (approx.) |
| Weight | 205 Grams |
| Operating Mode | Automatic |
| Contact Material | Silver |
| Compliance | VDE |

Figure 5: Product dimensions and detailed specifications.
9. Warranty and Support
For warranty information and customer support, please refer to the documentation included with your purchase or visit the official DEWIN website.
- Manufacturer: DEWIN
- Contact: Refer to your purchase receipt or the DEWIN official website for customer service contact details.