DEWIN IXRAQCCXD-GS109786Z

Rate this product if you’ve used it
Download PDF
Contents

DEWIN 40A AC220V 2P DIN Rail Adjustable Over/Under Voltage Protection Device User Manual

Model: IXRAQCCXD-GS109786Z

1. Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of the DEWIN 40A AC220V 2P DIN Rail Adjustable Over/Under Voltage Protection Device. This device is designed to safeguard electrical equipment from damage caused by voltage fluctuations, including overvoltage, undervoltage, and overcurrent conditions. It automatically disconnects power when abnormal voltage is detected and restores it once normal conditions resume, without requiring manual intervention.

Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. Product Overview

2.1 Key Features

  • Automatic Protection: Instantly cuts power during overvoltage, undervoltage, or overcurrent events to protect electrical equipment.
  • Automatic Reset: Automatically restores power when line voltage returns to normal, eliminating the need for manual operation.
  • Dual Display: Features a clear LCD for real-time display of voltage and current status.
  • Durable Construction: Made from high-quality, flame-retardant PC material, offering insulation protection and a long mechanical life.
  • DIN Rail Mounting: Designed for easy installation on a standard 35mm DIN rail without screws.
  • Adjustable Parameters: Allows users to set overvoltage, undervoltage, and delay parameters.

2.2 Product Components and Interface

The device features a compact design with an intuitive interface for monitoring and adjustment.

Front view of the DEWIN voltage protection device with digital displays

Figure 2.1: Front view of the DEWIN voltage protection device, showing the dual digital displays for voltage and current, along with indicator lights and control buttons.

Detailed view of the DEWIN voltage protection device interface

Figure 2.2: Detailed interface description, highlighting incoming and outgoing line terminals (N and L), operating current/voltage display, settings button, and adjustment keys.

  • Incoming Line N / L: Terminals for neutral and live incoming power.
  • Outgoing Line N / L: Terminals for neutral and live outgoing power to the load.
  • Operating Current/Voltage Display: Digital readouts showing real-time voltage and current.
  • Work Indicator Light: Indicates operational status.
  • Settings Button (SET): Used to enter parameter adjustment mode.
  • Adjustment Keys (Up/Down Arrows): Used to increase or decrease parameter values.

3. Specifications

The following table details the technical specifications of the DEWIN Voltage Protection Device:

Diagram showing dimensions and key specifications of the DEWIN voltage protector

Figure 3.1: Product dimensions and a summary of technical specifications.

ParameterValue
MaterialPC (Flame Retardant)
Rated VoltageAC 220V
Input Voltage RangeAC 140-300V
Rated Insulation Voltage450V
Rated Current40A
Rated Frequency50/60 Hz
Overvoltage Adjustable RangeAC 230-300V (Default: 270V)
Undervoltage Adjustable RangeAC 140-210V (Default: 170V)
Power Consumption≤ 2W
Power-on Delay1-500s (Default: 10s)
Action Delay0.1-30s (Default: 1s)
Output Contact1NO
Protection LevelIP20
Operating Temperature-5°C to 40°C
Dimensions (L x W x H)Approx. 9.4 x 7.8 x 4.7 cm
Weight180 grams

4. Safety Instructions

To prevent personal injury or damage to the device and connected equipment, observe the following safety precautions:

  • Installation and maintenance should only be performed by qualified personnel.
  • Ensure the main power supply is disconnected before any installation or wiring work.
  • Verify that the device's specifications (voltage, current) match your electrical system requirements.
  • Do not operate the device in wet or damp conditions.
  • Do not attempt to open or modify the device. There are no user-serviceable parts inside.
  • Ensure proper grounding according to local electrical codes.
  • Keep children away from electrical installations.

5. Installation

5.1 Mounting

The DEWIN Voltage Protection Device is designed for installation on a standard 35mm DIN rail. No screws are required for mounting.

  1. Ensure the main power supply is turned off at the circuit breaker.
  2. Align the device with the DIN rail.
  3. Press the device firmly onto the DIN rail until it clicks into place.
Close-up of the snap-on DIN rail mounting mechanism and internal components

Figure 5.1: Illustration of the snap-on design for easy DIN rail installation.

5.2 Wiring

Connect the device to your electrical circuit as shown in the wiring diagram below. Ensure all connections are secure and correctly polarized.

Wiring diagram for the DEWIN voltage protection device, showing connections to main power switch and air switch

Figure 5.2: Wiring diagram for top-in and bottom-out configuration. Connect the incoming line (L in, N in) from the main power switch to the top terminals of the protector, and the outgoing line (L out, N out) to the load or air switch from the bottom terminals.

  • Connect the incoming Live (L in) and Neutral (N in) wires from your main power source (e.g., main power switch) to the corresponding top terminals of the protection device.
  • Connect the outgoing Live (L out) and Neutral (N out) wires from the bottom terminals of the protection device to your electrical load or downstream circuit breaker (e.g., air switch).
  • Ensure all wire connections are tight to prevent loose contacts and overheating.

6. Operation

6.1 Power On and Initial Display

After successful installation and wiring, turn on the main power supply. The device will perform a self-check and then display the real-time voltage and current on its LCD screen. The "POWER" indicator light will illuminate.

6.2 Parameter Adjustment

You can adjust the overvoltage, undervoltage, and delay parameters to suit your specific requirements.

  1. Enter Settings Mode: Press and hold the SET button for approximately 3 seconds until the display starts flashing, indicating you are in settings mode.
  2. Navigate Parameters: Briefly press the SET button to cycle through the adjustable parameters:
    • Overvoltage Protection Value (V>)
    • Undervoltage Protection Value (V<)
    • Overcurrent Protection Value (A>) - Note: This model is primarily for voltage protection, current protection may be a fixed or non-adjustable feature depending on the specific variant. Refer to the display for current settings.
    • Power-on Delay Time (t-ON)
    • Action Delay Time (t-OFF)
  3. Adjust Values: While a parameter is flashing, use the Up (▲) and Down (▼) arrow buttons to increase or decrease the value.
  4. Save Settings: After adjusting a parameter, wait for approximately 5 seconds without pressing any buttons. The device will automatically save the new setting and exit the settings mode. Alternatively, you can briefly press the SET button to move to the next parameter and continue adjusting.

Default Settings:

  • Overvoltage: 270V
  • Undervoltage: 170V
  • Power-on Delay: 10s
  • Action Delay: 1s

6.3 Protection Function

When the detected voltage or current exceeds the set limits, the device will automatically disconnect the power supply to protect connected equipment. The corresponding indicator light (V>, V<, A>) will illuminate. Once the voltage returns to within the safe operating range and the set delay time has passed, the device will automatically reconnect the power.

Diagram illustrating automatic power off when overloaded with adjustable ranges

Figure 6.1: Visual representation of the automatic power-off function during overload conditions, highlighting adjustable overvoltage, undervoltage, and reset delay ranges.

7. Maintenance

The DEWIN Voltage Protection Device requires minimal maintenance. Follow these guidelines to ensure optimal performance and longevity:

  • Cleaning: Periodically clean the exterior of the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure power is disconnected before cleaning.
  • Inspection: Regularly inspect the wiring connections for any signs of loosening or damage. Ensure the device is securely mounted on the DIN rail.
  • Environmental Conditions: Ensure the device is operated within its specified temperature range (-5°C to 40°C) and protected from excessive dust and moisture.
  • No User Serviceable Parts: Do not attempt to open the device for internal maintenance or repairs. Refer to qualified service personnel if the device malfunctions.

8. Troubleshooting

If you encounter issues with your DEWIN Voltage Protection Device, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Device does not power on.No incoming power; incorrect wiring; device fault.Check main power supply. Verify wiring connections. If power is present and wiring is correct, the device may be faulty; contact support.
Power is cut, and V> or V< indicator is on.Overvoltage or undervoltage condition detected.This is normal operation. The device will automatically reset when voltage returns to normal. Check your power supply for stability.
Device frequently trips.Unstable power supply; protection parameters set too sensitively.Monitor your power supply for fluctuations. Adjust overvoltage/undervoltage parameters to a less sensitive range if frequent, minor fluctuations are acceptable for your equipment.
Cannot adjust parameters.Not in settings mode; buttons not responding.Press and hold the SET button for 3 seconds to enter settings mode. If buttons are unresponsive, power cycle the device.
Display is blank or erratic.Power issue; internal fault.Check power supply. Power cycle the device. If the problem persists, contact support.

If the problem persists after attempting these solutions, please contact DEWIN customer support for further assistance.

9. Warranty and Support

Specific warranty information for this product may vary by region and retailer. Please refer to the warranty card included with your purchase or contact your point of sale for details.

For technical support, product inquiries, or service requests, please contact DEWIN customer service through the official website or your retailer. When contacting support, please have your product model number (IXRAQCCXD-GS109786Z) and purchase date available.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?