1. Introduction
Thank you for choosing the Livpure Aerofrost Desert Air Cooler 85L. This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your new air cooler. Please read it thoroughly before use and retain it for future reference.

Image: Livpure Aerofrost Desert Air Cooler 85L, front view.
2. Important Safety Instructions
To reduce the risk of fire, electric shock, or injury, always follow these basic safety precautions:
- Read all instructions before using the appliance.
- Ensure the power supply voltage matches the rating label on the cooler.
- Do not operate the cooler with a damaged cord or plug.
- Keep the cooler away from heat sources and direct sunlight.
- Do not immerse the cooler, cord, or plug in water or other liquids.
- Always unplug the cooler before cleaning, servicing, or moving it.
- Ensure the water tank is filled with clean water only.
- Keep doors and windows open for effective cooling and proper ventilation.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
3. Package Contents
Verify that all items are present in the package:
- 1 x Livpure Aerofrost Desert Air Cooler (85L)
- 5 x Caster Wheels
- 1 x User Manual
4. Setup Instructions
4.1 Attaching the Caster Wheels
- Carefully tilt the cooler to access its underside.
- Insert each of the 5 caster wheels into the designated slots on the base of the cooler. Ensure they are securely fitted.
- Return the cooler to an upright position. The multi-directional wheels allow for easy movement.

Image: Underside of the cooler showing the attachment points for caster wheels.
4.2 Filling the Water Tank
- Locate the water inlet on the cooler.
- Fill the 85-liter water tank with clean water. Do not overfill; observe the water level indicator.
- For enhanced cooling, utilize the integrated ice chamber by adding ice cubes.

Image: Top panel of the cooler with controls and open ice chamber.
4.3 Placement
Position the cooler in a well-ventilated area. For optimal cooling performance, ensure doors and windows are open to allow for air circulation.
5. Operating Instructions
The Livpure Aerofrost 85L features user-friendly knob controls for speed and mode selection.

Image: Front view of the cooler, showing the control panel with Speed and Mode knobs.
5.1 Powering On/Off
Plug the cooler into a suitable power outlet. Turn the 'Mode' knob to the 'ON' position to start the cooler.
5.2 Adjusting Fan Speed
Use the 'Speed' knob to select your desired fan speed. The cooler offers 3 speed settings for customized airflow.
5.3 Selecting Operation Mode
The 'Mode' knob allows you to switch between different operational modes, typically including Fan Only and Cooling modes. Refer to the labels on the control panel for specific options.
5.4 Air Delivery and Coverage
This cooler provides 5500 CMH air delivery and a 43-foot air throw distance, suitable for rooms up to 647 sq. ft. Its powerful blower ensures comfortable cooling.

Image: Livpure Aerofrost Cooler in a room, illustrating its air throw capability.
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your air cooler.
6.1 Cleaning the Honeycomb Pads
The cooler is equipped with anti-bacterial honeycomb pads. Periodically clean these pads to prevent dust buildup and maintain air quality. Refer to the cooler's design for access to the pads. Gently rinse them with water and allow them to dry completely before reinstallation.

Image: Close-up of honeycomb cooling pads, illustrating their structure.
6.2 Water Tank Cleaning
Drain and clean the water tank regularly to prevent algae or mold growth. Use a mild detergent and rinse thoroughly. Ensure the tank is dry before refilling if storing the cooler.
6.3 Exterior Cleaning
Wipe the exterior of the cooler with a soft, damp cloth. Do not use abrasive cleaners or solvents.
7. Troubleshooting
If you encounter issues with your cooler, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Cooler does not turn on | No power supply; Power cord not plugged in; Power switch off | Check power outlet; Ensure cord is securely plugged in; Turn power switch to ON |
| No cooling effect | Water tank empty; Honeycomb pads dry; Room not ventilated | Fill water tank; Ensure water pump is operating; Open doors/windows for cross-ventilation |
| Reduced airflow | Dust buildup on pads; Fan obstruction | Clean honeycomb pads; Check for any obstructions to the fan blades |
| Unpleasant odor | Stagnant water in tank; Dirty pads | Drain and clean water tank; Clean or replace honeycomb pads |
If the problem persists after attempting these solutions, please contact customer support.
8. Product Specifications
| Feature | Detail |
|---|---|
| Brand | Livpure |
| Model Name | AEROFROST-85L |
| Material | Plastic |
| Mounting Type | Freestanding |
| Special Features | Adjustable Speed, Portable (with multi-directional wheels) |
| Colour | White |
| Air Flow Capacity | 3200 Cubic Feet Per Minute (CFM) / 5500 CMH |
| Controls Type | Knob |
| Reservoir Capacity | 85 Liters (with Ice Chamber) |
| Floor Area Coverage | Up to 647 Square Feet |
| Item Weight | 19 Kilograms |
| Wattage | 220 Watts |
| Noise Level | 52 Decibels |
| Number Of Speeds | 3 |
| Voltage | 230 Volts |
| Operation Mode | Manual |
| Item Dimensions (D x W x H) | 46D x 65.5W x 123H Centimeters |
| Included Components | 1 Aircooler, 5 Caster Wheels, User Manual |
9. Warranty & Support
9.1 Warranty Information
Your Livpure Aerofrost Desert Air Cooler 85L comes with a warranty of 1 Year on the Product and 2 Years on the Fan Motor from the date of purchase. Please retain your purchase receipt for warranty claims. The warranty covers manufacturing defects under normal use conditions.
9.2 Customer Support
For any queries, service requests, or technical assistance, please contact Livpure customer support:
- Toll-Free Number: 1800-419-9399
- Email: customercare@livpure.com
- Manufacturer: Livpure Private Limited