Introduction
The MEDION P250 Cordless Handheld Vacuum Cleaner (Model E250S) is a versatile 2-in-1 device designed for efficient cleaning of various surfaces. This manual provides essential information for safe operation, assembly, maintenance, and troubleshooting to ensure optimal performance and longevity of your appliance. Please read this manual thoroughly before first use and keep it for future reference.
Safety Instructions
To prevent injury or damage, always observe the following safety precautions:
- Read all instructions carefully before using the appliance.
- Keep the vacuum cleaner away from water and do not immerse it in liquids.
- Do not vacuum liquids, hot ashes, burning cigarettes, or sharp objects.
- Ensure all filters are correctly installed before operating the vacuum cleaner.
- Use only the power adapter supplied with the device for charging.
- Keep the appliance out of reach of children and pets.
- Do not operate the vacuum cleaner if the power cord, plug, or the appliance itself is damaged.
- Avoid blocking the air inlets or outlets during operation.
Package Contents
Verify that all items listed below are included in your package:
- MEDION P250 Cordless Stick Vacuum Cleaner (Main Unit)
- Power Adapter
- Fluffy Brush
- 2-in-1 Dust Nozzle
- Crevice Nozzle
- Wall Mount
- User Manual

Image: MEDION P250 Cordless Vacuum Cleaner with all included accessories.
Product Overview
The MEDION P250 features a powerful 250-watt motor with bagless cyclonic technology, offering 3 suction levels and a dust sensor for automatic power adjustment. It includes a motorized brush with LED lighting and a removable brush roller, suitable for both carpets and hard floors. The integrated LED touch display provides status information and allows for easy suction power adjustment.

Image: User operating the MEDION P250, highlighting its 22 kPa suction power and bagless cyclonic technology.
Setup
1. Assembly
- Attach the main unit (with dust container) to the extension tube until it clicks into place.
- Connect the desired cleaning head (e.g., Fluffy Brush) to the other end of the extension tube. For handheld use, attach accessories directly to the main unit.
2. Charging
- Connect the power adapter to the charging port located on the main unit.
- Plug the adapter into a standard wall outlet. The LED display will show the charging status.
- A full charge typically takes approximately 300 minutes and provides up to 1 hour of operation, depending on the selected power level.
3. Wall Mount Installation
- Select a suitable location on a wall, preferably near a power outlet, to install the wall mount.
- Secure the wall mount to the wall using appropriate screws and anchors (not included). Ensure it is firmly attached.
- The wall mount is designed to hold the vacuum cleaner and can also function as a charging station when the power adapter is connected.

Image: Practical wall mount with charging function for the MEDION P250.
Operating
1. Power On/Off
Press the power button located on the handle to turn the vacuum cleaner on or off.
2. Suction Power Adjustment
Use the LED touch display to select one of the three available suction power levels (Low, Medium, High) according to your cleaning needs. The vacuum cleaner also features an automatic mode.

Image: LED Touch Display for status indication and suction power adjustment.
3. Dust Sensor
The integrated dust sensor automatically detects the amount of dust and debris on the surface and adjusts the suction power for optimal cleaning efficiency. This feature helps conserve battery life and ensures thorough cleaning.

Image: Dust sensor for automatic suction power adjustment.
4. LED Lighting
The motorized brush head is equipped with LED lights that illuminate dark areas, such as under furniture or in corners, making it easier to spot and clean hidden dust and debris.

Image: Motorized brush with LED lighting and replaceable brush roller.
Maintenance
1. Emptying the Dust Container
- Ensure the vacuum cleaner is turned off.
- Press the release button to detach the dust container from the main unit.
- Position the dust container over a waste bin. Open the bottom flap of the dust container and empty its contents.
- Close the flap securely and reattach the dust container to the main unit until it clicks into place.
2. Cleaning Filters
Regularly clean the HEPA filter and other internal filters to maintain optimal suction power.
- Remove the filters from the dust container.
- Gently tap the filters over a waste bin to remove accumulated dust.
- If the filters are washable, rinse them with cold water. Do not use detergents or hot water.
- Allow the filters to air dry completely for at least 24 hours before reinstallation. Do not use the vacuum cleaner with wet filters.
3. Brush Roller Maintenance
- Turn off the vacuum cleaner and detach the motorized brush head from the extension tube.
- Unlock the mechanism to remove the brush roller from the brush head.
- Carefully remove any tangled hair, threads, or debris from the brush roller and its housing.
- Reinstall the brush roller and secure it in place. Reattach the brush head to the extension tube.
Troubleshooting
If you encounter issues with your MEDION P250, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Vacuum cleaner does not turn on. | Battery is discharged. | Charge the battery fully. |
| Power button not pressed correctly. | Ensure the power button is pressed firmly. | |
| Reduced suction power. | Dust container is full. | Empty the dust container. |
| Filters are clogged. | Clean or replace the filters. | |
| Nozzle, tube, or brush head is blocked. | Remove any obstructions. | |
| Brush roller not spinning. | Obstruction in the brush roller. | Remove tangled hair or debris from the brush roller. |
| Brush head not correctly attached. | Ensure the brush head is securely attached. | |
| Unusual noise during operation. | Foreign object lodged in the vacuum. | Turn off the vacuum immediately and check for foreign objects in the brush head or air ducts. |
Specifications
| Brand | MEDION |
| Model Number | E250S |
| Power | 250 Watts |
| Voltage | 220 Volts |
| Battery Type | Lithium-Ion |
| Battery Life | Up to 1 hour |
| Charging Time | Approximately 300 minutes |
| Suction Power | 22 kPa |
| Number of Speeds | 3 |
| Noise Level | 80 Decibels |
| Filter Type | HEPA H13, Cartridge |
| Dust Container Capacity | Bagless |
| Dimensions (L x W x H) | 17.5 x 26 x 116 cm |
| Item Weight | 2.1 Kilograms |
| Special Features | Dust Sensor, LED Touch Display, Motorized Brush with LED Lighting, Wall Mount with Charging Function |

Image: Dimensions of the MEDION P250 Cordless Vacuum Cleaner.
Warranty and Support
For detailed warranty information, terms, and conditions, please refer to the official MEDION website or the documentation provided with your purchase. In case of technical issues, questions, or to request support, please contact MEDION customer service or your local retailer. Keep your proof of purchase (receipt or invoice) as it will be required for any warranty claims.