1. Product Overview
The RunTru 2 Ton Straight Cool 15.2 SEER2 System with Heater is a comprehensive solution for residential heating and cooling needs. This system includes an A4AC5 Air Conditioner, an A4AH4 Air Handler, and a field-installed heater, designed to provide efficient and reliable climate control.

Image: Complete RunTru 2 Ton Straight Cool 15.2 SEER2 System, showing the outdoor condenser unit, indoor air handler, and heater components.
Key Components:
- A4AC5 Air Conditioner: An outdoor unit designed for efficient cooling, operating quietly at 71-74 dB.
- A4AH4 Air Handler: An indoor unit featuring an all-aluminum coil, factory-installed flow control, fully insulated galvanized steel cabinet, and multi-speed fan motors for consistent air distribution.
- Heater: Field-installed component for heating functionality.
Energy Efficiency (SEER2):
SEER2 (Seasonal Energy Efficiency Ratio 2) measures the total heat removed from the conditioned space during the annual cooling season. This system boasts a 15.2 SEER2 rating, indicating high energy efficiency. The new M1 testing procedure for SEER2 increases external static pressure by a factor of five to better reflect real-world installation conditions.
Compared to older 10 SEER units, this system can provide significant energy savings. Higher SEER ratings directly correlate with greater energy efficiency, leading to lower operating costs.
Operating Stages:
- Single-Stage Systems: Operate at a single speed, turning off completely once the desired temperature is reached.
- Two-Stage Systems: Alternate between a low and high speed, offering improved comfort and efficiency by running at a lower speed for longer periods.
- Variable Speed Systems: Continuously vary their speed to maintain the ideal temperature, providing the highest level of comfort and efficiency. These systems run more continuously, similar to a dimmer switch, automatically adjusting output as needed.
2. Package Contents
Upon receiving your RunTru HVAC system, please verify that all components are present and undamaged. The package typically includes:
- Air Handler (A4AH4E30A1B60A)
- Condenser (A4AC5024D1000A)
- Heater (Field Installed)
3. Safety Information
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Installation and service must be performed by a qualified installer or service agency.
- Always disconnect power to the unit before performing any maintenance or service.
- Wear appropriate personal protective equipment (PPE), including gloves and eye protection, during installation and service.
- Ensure proper grounding of all electrical components.
- Do not store flammable materials near the unit.
- Keep children and pets away from the unit during operation and maintenance.
- Refer to all local and national electrical and building codes during installation.
4. Setup and Installation
Installation of this HVAC system requires specialized knowledge and tools. It is strongly recommended that installation be performed by a certified HVAC professional.
General Installation Steps (for professional reference):
- Site Preparation: Ensure adequate space and proper foundation for the outdoor condenser unit and indoor air handler.
- Ductwork Connection: Connect the air handler to the existing or new ductwork system.
- Refrigerant Line Installation: Install and connect the refrigerant lines between the condenser and air handler. Ensure proper evacuation and charging of the system.
- Electrical Wiring: Connect the units to the appropriate power supply according to wiring diagrams and local electrical codes.
- Condensate Drain: Install and properly route the condensate drain line from the air handler.
- Heater Installation: Integrate the field-installed heater into the air handler as per manufacturer instructions.
- System Start-up and Testing: Perform initial start-up procedures, check refrigerant levels, airflow, and overall system operation.
5. Operating Instructions
Once installed, your RunTru HVAC system is controlled primarily through your home's thermostat. Familiarize yourself with your thermostat's specific functions for optimal use.
Basic Operation:
- Cooling Mode: Set your thermostat to 'Cool' mode and select your desired temperature. The system will activate the air conditioner to cool your home.
- Heating Mode: Set your thermostat to 'Heat' mode and select your desired temperature. The system will activate the heater to warm your home.
- Fan Mode: You can typically set the fan to 'Auto' (runs only when heating/cooling) or 'On' (runs continuously for air circulation).
For systems with multiple stages or variable speed, the unit will automatically adjust its operation based on the thermostat's demand and the system's internal logic to maintain comfort and efficiency.
6. Maintenance
Regular maintenance is crucial for the longevity, efficiency, and optimal performance of your RunTru HVAC system. It is recommended to schedule professional maintenance annually.
User Maintenance:
- Air Filter Replacement: Check your air filter monthly and replace it every 1-3 months, or more frequently if you have pets or allergies. A clean filter ensures proper airflow and system efficiency.
- Clear Outdoor Unit: Keep the area around the outdoor condenser unit free from debris, leaves, and vegetation to ensure proper airflow.
- Condensate Drain: Periodically check the condensate drain line for clogs.
Professional Maintenance (Recommended Annually):
- Coil cleaning (evaporator and condenser coils)
- Refrigerant level check and adjustment
- Electrical connection inspection and tightening
- Blower motor and fan inspection
- Drain line cleaning and inspection
- Overall system performance check
7. Troubleshooting
Before contacting a service technician, review the following common issues and potential solutions. For complex problems, always contact a qualified HVAC professional.
| Problem | Possible Cause | Solution |
|---|---|---|
| System not cooling/heating | Thermostat settings incorrect Dirty air filter Power supply issue Refrigerant leak (cooling) | Check thermostat mode and temperature setting Replace or clean air filter Check circuit breaker Contact professional for inspection |
| Weak airflow | Dirty air filter Blocked return air vents Ductwork leaks | Replace or clean air filter Ensure vents are unobstructed Contact professional for duct inspection |
| Unusual noises (grinding, squealing) | Loose parts Motor issues Fan blade obstruction | Turn off unit and inspect for loose panels Contact professional for diagnosis and repair |
| Unit constantly running or short cycling | Improper sizing Thermostat malfunction Refrigerant issues | Contact professional for system evaluation |
8. Specifications
Detailed specifications for the RunTru 2 Ton Straight Cool 15.2 SEER2 System with Heater:

Image: RunTru A4AC5024D1000A Condenser Unit, the outdoor component of the HVAC system.
Condenser (A4AC5024D1000A):
- Nominal Sound: 71-74 dB
- Capacity: 2 Tons (24000 British Thermal Units)
- Vapor Line: 3/4"
- Dimensions (W x H x D): 30 x 29 x 30 inches
- Model Info: A4AC5024D1000A
- Part Number: A4AC4

Image: RunTru A4AH4E30A1B60A Air Handler Unit, the indoor component of the HVAC system.
Air Handler (A4AH4E30A1B60A):
- Electric Heat: Field Installed
- Capacity (Tons): 1.5-3.0
- Motor Type: CTM
- Flow Control: FCCV
- Dimensions (W x H x D): 19 x 45 x 21 inches
General System Specifications:
- Brand Name: RunTru
- Item Weight: 300 pounds (total system)
- Country of Origin: USA
- Efficiency: High (15.2 SEER2)
- Annual Energy Consumption: 75 Watts
- Noise Level: 75 dB (overall system)
- Installation Type: Split System
- Special Features: Heating And Cooling Function
- Color: Gray
- Voltage: 220V
- Wattage: 220W
- Material Type: Steel
- Date First Available: November 27, 2023
9. Warranty and Support
For specific warranty terms and conditions, please refer to the warranty documentation provided with your purchase or contact your authorized RunTru dealer or installer. Warranty coverage typically includes parts and may vary based on registration and installation by a qualified professional.
Customer Support:
For technical assistance, service, or warranty claims, please contact the HVAC professional who installed your system. They are best equipped to provide support and service for your RunTru unit.
You may also visit the official RunTru website for additional resources, product information, and to locate authorized service providers in your area.





