INKBIRDPLUS WK

INKBIRDPLUS Digital Thermostat Outlet WK User Manual

Model: WK

1. Introduction

This manual provides detailed instructions for the operation and maintenance of your INKBIRDPLUS Digital Thermostat Outlet, Model WK. This device is designed to precisely control temperature for various applications, offering both heating and cooling modes, along with versatile timing functions. Please read this manual thoroughly before use to ensure proper functionality and safety.

INKBIRDPLUS Digital Thermostat Outlet WK

Image 1.1: INKBIRDPLUS Digital Thermostat Outlet WK with temperature probe.

2. Product Overview

2.1 Key Features

  • Heating & Cooling Modes: Automatically switches between heating and cooling based on set temperatures.
  • Plug and Play Operation: Simple setup, just plug into a standard outlet.
  • Timing Functions: Includes Cycle Timer (F01), Countdown ON (F02), Countdown OFF (F03), and Countdown ON/OFF (F04) modes.
  • Wide Temperature Control Range: -40°F to 248°F (-40°C to 120°C).
  • Backlit LCD Display: Clear visibility of current and set temperatures in various lighting conditions.
  • Additional Functions: Temperature calibration, memory function, reset option, and screen lock protection.

2.2 Components and Display

Familiarize yourself with the device's buttons and display indicators:

Diagram of INKBIRDPLUS Thermostat Outlet with labeled buttons and display sections

Image 2.1: Labeled diagram of the thermostat outlet's display and control buttons.

  • Measured Temperature: Displays the current temperature detected by the probe.
  • Start Temperature (ON): The temperature at which the connected appliance will turn ON.
  • Stop Temperature (OFF): The temperature at which the connected appliance will turn OFF.
  • Output Work Indicator: Illuminates when the outlet is providing power to the connected appliance.
  • MODE Button: Used to switch between temperature control and timing modes.
  • SET Button: Used to enter setting mode and confirm selections.
  • UP Button: Used to increase values or navigate menus.
  • DOWN Button: Used to decrease values or navigate menus.
  • Reset Button: A small button (often recessed) to restore factory settings.

3. Setup Instructions

3.1 Initial Connection

  1. Plug the INKBIRDPLUS Digital Thermostat Outlet into a standard 110V-120V AC power outlet.
  2. Connect your heating or cooling appliance (e.g., heater, fan, refrigerator) to the outlet on the thermostat. Ensure the appliance's power consumption does not exceed 15A/1800W.
  3. Place the temperature probe in the desired location where you want to monitor and control the temperature. Ensure the probe is not directly exposed to heat sources or drafts that could skew readings.

4. Operating Instructions

4.1 Temperature Control Mode (Heating/Cooling)

The device operates in either heating or cooling mode based on your set temperatures.

Thermostat outlet controlling a refrigerator for cooling and a heater for heating

Image 4.1: Example applications for heating and cooling control.

  • Setting Heating Mode: Set the 'Start Temperature (ON)' to be lower than the 'Stop Temperature (OFF)'. The device will activate the connected appliance when the measured temperature drops below the 'Start Temperature' and turn it off when it reaches the 'Stop Temperature'.
  • Setting Cooling Mode: Set the 'Start Temperature (ON)' to be higher than the 'Stop Temperature (OFF)'. The device will activate the connected appliance when the measured temperature rises above the 'Start Temperature' and turn it off when it drops to the 'Stop Temperature'.

To adjust temperature settings:

  1. Press the SET button once. The 'Start Temperature (ON)' will flash.
  2. Use the UP or DOWN buttons to adjust the desired 'Start Temperature'.
  3. Press SET again. The 'Stop Temperature (OFF)' will flash.
  4. Use the UP or DOWN buttons to adjust the desired 'Stop Temperature'.
  5. Press SET a third time to confirm and exit the setting mode. The display will return to showing the measured temperature.

4.2 Timing Functions

The thermostat offers four timing modes (F01-F04). Press the MODE button repeatedly to cycle through these options.

F01: Cycle Timer Mode

This mode allows the appliance to cycle ON and OFF for set durations. For example, ON for 12 hours, then OFF for 12 hours, repeating.

Diagram showing F01 Cycle Timer mode with ON and OFF durations

Image 4.2: F01 Cycle Timer Mode illustration.

F02: Countdown ON Mode

The appliance will remain OFF for a set countdown period, then turn ON and stay ON indefinitely.

Diagram showing F02 Countdown ON mode with OFF duration before turning ON

Image 4.3: F02 Countdown ON Mode illustration.

F03: Countdown OFF Mode

The appliance will remain ON for a set countdown period, then turn OFF and stay OFF indefinitely.

Diagram showing F03 Countdown OFF mode with ON duration before turning OFF

Image 4.4: F03 Countdown OFF Mode illustration.

F04: Countdown ON and Countdown OFF Mode

The appliance will turn ON for a set duration, then turn OFF for another set duration, and then stay OFF indefinitely.

Diagram showing F04 Countdown ON and OFF mode with sequential ON and OFF durations

Image 4.5: F04 Countdown ON and OFF Mode illustration.

To set timing functions (for any F01-F04 mode):

  1. Press the MODE button until the desired timing mode (F01-F04) is displayed.
  2. Press the SET button. The first time parameter (e.g., ON hours for F01) will flash.
  3. Use the UP or DOWN buttons to adjust the value.
  4. Press SET to move to the next time parameter (e.g., ON minutes, then OFF hours, etc.).
  5. Repeat step 3 and 4 until all parameters are set.
  6. Press SET one last time to confirm and exit the setting mode.

5. Calibration

If you suspect the temperature reading is inaccurate, you can calibrate the device:

  1. Unplug the thermostat from the power outlet.
  2. Plug the thermostat back into the power outlet.
  3. Immediately after plugging in, press and hold the MODE button for a few seconds until the screen indicates it is in calibration mode.
  4. Use the UP or DOWN buttons to adjust the temperature reading to match a known accurate thermometer.
  5. Press the SET button to confirm the calibration and exit the mode.

6. Maintenance

  • Keep the device clean by wiping it with a dry, soft cloth. Do not use abrasive cleaners or immerse the device in water.
  • Ensure the temperature probe is clean and free from debris for accurate readings.
  • Avoid placing the device in areas with extreme humidity, dust, or direct sunlight.
  • Regularly check the power cord and probe cable for any signs of damage.

7. Troubleshooting

7.1 Common Issues

  • Inaccurate Temperature Reading:
    • Ensure the probe is correctly placed and not affected by external factors (e.g., direct sunlight, drafts, or being too close to the appliance being controlled).
    • Perform a temperature calibration as described in Section 5.
    • Check the probe cable for damage. A damaged probe may require replacement.
  • Appliance Not Turning ON/OFF:
    • Verify that the 'Start Temperature' and 'Stop Temperature' are set correctly for either heating or cooling mode (refer to Section 4.1).
    • Ensure the connected appliance is properly plugged into the thermostat outlet and is functioning independently.
    • Check if the thermostat is in a timing mode (F01-F04) that might override temperature control. Switch back to temperature control mode if necessary.
    • Confirm the appliance's power draw does not exceed the thermostat's maximum capacity (15A/1800W).
  • Display Not Working:
    • Ensure the thermostat is securely plugged into a live power outlet.
    • If the screen is locked, unlock it according to the device's specific instructions (usually a combination of button presses).
    • Try resetting the device by pressing the recessed Reset button.

8. Specifications

Dimensions of the INKBIRDPLUS Thermostat Outlet

Image 8.1: Product dimensions.

FeatureSpecification
Power SupplyAC 120V±15% 60Hz
Temperature Control Range-40°F to 248°F (-40°C to 120°C)
Control Accuracy±1%
OutputMax 15A/120V (Resistive load less than 15A, Inductive load less than 2A)
Timing Range0-99 hours 59 minutes
Display TypeBacklit LCD
Product Dimensions3.7"D x 2.5"W x 5.5"H
Item Weight6.2 ounces
MaterialPlastic

9. Warranty and Support

For warranty information and technical support, please refer to the documentation included with your product or visit the official INKBIRDPLUS website. Keep your purchase receipt as proof of purchase for warranty claims.

Related Documents - WK

Preview INKBIRDPLUS T01 Prise Thermostat Minuterie Manuel de l'Utilisateur
Manuel d'utilisation pour la prise thermostat minuterie INKBIRDPLUS T01. Guide complet sur les fonctions de contrôle de température et de minuterie, les modes de fonctionnement, le calibrage et les spécifications techniques.
Preview INKBIRDPLUS PTH-9A Multi-Function Air Quality Detector User Manual
Comprehensive user manual for the INKBIRDPLUS PTH-9A Multi-Function Air Quality Detector, covering product introduction, specifications, operation instructions, time/date setting, and warranty information. Monitor PM2.5, PM10, CO2, temperature, and humidity.
Preview INKBIRDPLUS HS-16 Metal Detector Owner's Manual and User Guide
Detailed user manual for the INKBIRDPLUS HS-16 metal detector, a waterproof handheld device with an LCD screen. Covers features, specifications, operation, and battery replacement for effective metal detection.