1. Introduction

This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of the Appion G5TWIN Twin Cylinder Refrigerant Recovery Unit. Please read this manual thoroughly before operating the unit.

1.1 Safety Warnings

WARNING: Always wear proper personal protective equipment (PPE) when operating the Appion G5TWIN unit. This includes, but is not limited to, safety glasses, gloves, and appropriate clothing to prevent contact with refrigerants.

This machine is intended for use by certified professionals only. Read the side panel and this manual before using.

Ensure adequate ventilation when operating the unit to prevent accumulation of refrigerant vapors.

2. Product Features

The Appion G5TWIN is designed for rapid and reliable refrigerant recovery. Key features include:

  • Compact and Lightweight Design: Weighs approximately 24 lbs, making it portable and easy to transport to various job sites, including rooftops and plant rooms.
  • Twin Cylinders and Twin Condensers: Engineered for ultra-fast liquid and vapor recovery, significantly reducing recovery time.
  • Refrigerant-Isolated Crankcase: This patented design ensures that the internal components of the crankcase do not come into contact with refrigerant, protecting against corrosive and damaging contaminants and enhancing durability.
  • No Purge Necessary: Due to the isolated crankcase, there is no volume of refrigerant within the crankcase, eliminating the need for a purge function.
  • High-Speed Cooling Fan: A 7-inch, 10-blade turbine fan operates at 3000 RPM, blasting over 600 CFM of cooling air over the twin heads and condensers. This improved cooling efficiency aids in heat rejection, keeping the unit up to 50°F cooler even in high ambient conditions.
  • Direct Liquid Recovery: Capable of direct liquid recovery without machine throttling, ensuring efficient operation.
  • Wide Refrigerant Compatibility: Suitable for use with all common refrigerants, including R410A, and A2L refrigerants such as R32 and R1234yf.
  • Simple Two-Valve Unit Control: User-friendly interface for straightforward operation.
  • Field Serviceable Modular Construction: Designed for easy replacement of gauges and an easy-to-clean inlet filter screen, allowing for on-site repairs and maintenance.
  • Ergonomic Handle: Compact casing with a rubber over-molded ergonomic handle for comfortable carrying.
  • Angled Fittings: 45-degree angled fittings facilitate easy connection of larger diameter hoses.

3. Components and Controls

Familiarize yourself with the main components and controls of the G5TWIN unit.

Appion G5TWIN Twin Cylinder Refrigerant Recovery Unit with dimensions
Figure 3.1: Front view of the Appion G5TWIN unit, showing the input/output ports, pressure gauges, and power switch. Dimensions are indicated as 11"H x 15"W x 12"D.
  • Power Switch: Controls the main power to the unit.
  • IN Port (Blue): Refrigerant input connection.
  • OUT Port (Red): Refrigerant output connection.
  • Pressure Gauges: Display system pressures.
  • Input Valve: Controls refrigerant flow into the unit.
  • Output Valve: Controls refrigerant flow out of the unit.
  • Inlet Filter Screen: Located at the input, designed to be easy to clean or replace for best results.

4. Setup

Proper setup is crucial for safe and effective refrigerant recovery.

4.1 Initial Inspection

  • Inspect the unit for any visible damage.
  • Ensure all connections are secure and free from debris.
  • Verify the power cord is in good condition.

4.2 Connecting Hoses

Connect appropriate refrigerant hoses to the IN and OUT ports. The 45-degree angled fittings are designed to accommodate larger diameter hoses for optimal flow.

Close-up of Appion G5TWIN ports with hoses connected
Figure 4.1: Close-up view of the G5TWIN's input and output ports, showing how hoses connect to the 45-degree angled fittings. The 'FOR BEST RESULTS CLEAN OR REPLACE FILTER SCREEN OFTEN' label is visible.

For enhanced performance, consider using Appion Speed Kit R hoses and valve core removal tools, which are designed to maximize flow and efficiency during recovery.

Video 4.1: Appion G5Twin Product Highlight Video by HVAC365. This video demonstrates the features and benefits of the G5TWIN unit, including its compact design, robust construction, and efficient recovery capabilities. It also shows the use of Speed Kit R accessories for optimal performance.

5. Operation

Follow these steps for safe and effective refrigerant recovery.

5.1 General Recovery Procedure

  1. Ensure all connections are tight and secure.
  2. Connect the IN port to the system being recovered and the OUT port to the recovery cylinder.
  3. Open the valves on the system and the recovery cylinder.
  4. Turn on the G5TWIN unit using the power switch.
  5. Monitor the pressure gauges to ensure proper operation and recovery progress.
  6. The unit is designed for direct liquid and vapor recovery without the need for throttling.
  7. Once recovery is complete, close the valves on the system and the recovery cylinder, then turn off the G5TWIN unit.
  8. Disconnect hoses carefully, being mindful of any residual pressure.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your G5TWIN unit.

6.1 Inlet Filter Screen

For best results, clean or replace the inlet filter screen often. A clogged filter can reduce recovery efficiency.

6.2 Field Serviceability

The G5TWIN features a modular design, allowing for easy field service. Components like gauges can be replaced, and internal parts are accessible for maintenance. Refer to the detailed service manual for specific repair procedures.

6.3 Crankcase Lubrication

The unit's crankcase is permanently lubricated and isolated from the refrigerant path, meaning it does not require regular oil changes or lubrication related to refrigerant exposure.

7. Troubleshooting

This section provides guidance for common issues. For complex problems, contact Appion technical support or a certified service technician.

ProblemPossible CauseSolution
Unit not powering onNo power supply, faulty power cord, tripped circuit breaker.Check power connection, inspect power cord, reset circuit breaker.
Slow recovery rateClogged inlet filter screen, restricted hoses, low refrigerant volume in system.Clean or replace inlet filter screen, check hoses for kinks or blockages, ensure adequate refrigerant in system for recovery.
Unit overheatingInsufficient airflow, prolonged operation in high ambient temperatures.Ensure unit is in a well-ventilated area, allow unit to cool down if operating continuously in extreme heat.
Unusual noise during operationLoose components, internal mechanical issue.Turn off unit immediately and inspect for loose parts. If noise persists, contact service.

8. Specifications

SpecificationValue
Model NameG5TWIN Twin Cylinder Recovery Unit
Model NumberG5TWIN
BrandAPPION
Product Dimensions (D x W x H)11"D x 15"W x 12"H
Item Weight27 Pounds
ConfigurationCompact Twin Cylinder
Voltage115 Volts (AC)
Refrigerant CompatibilityAll common refrigerants, including R410A, R32, R1234yf (A2L refrigerants)
Compressor TypeReciprocating
Power SourceCorded Electric
Included ComponentsMachine
CertificationUL, DOE

9. Warranty and Support

The Appion G5TWIN Twin Cylinder Refrigerant Recovery Unit comes with a one-year warranty. For warranty claims, technical support, or service inquiries, please contact your local Appion distributor or visit the official Appion website.

© 2023 APPION. All rights reserved.