SPABOY ZJLCD-BT01
User Manual
SPABOY ZJLCD-BT01 Turbine Flow Meter
Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the SPABOY ZJLCD-BT01 Turbine Flow Meter. Please read this manual thoroughly before using the device to ensure proper function and longevity.
The ZJLCD-BT01 is an electronic PVC LCD digital display flowmeter designed for accurate measurement of liquid flow, commonly used in farm and garden irrigation systems.
Product Overview

Figure 1: Front view of the ZJLCD-BT01 Turbine Flow Meter, showing the LCD display, SET button, and CLEAR button.

Figure 2: Angled view of the flow meter, highlighting the PVC pipe connections on both ends.

Figure 3: Close-up of the LCD display, showing the digital readout for flow measurement.

Figure 4: The LCD display indicating both instantaneous flow rate (top) and total accumulated flow (bottom).

Figure 5: The flow meter model without an external power cable, typically battery-powered.

Figure 6: The flow meter model with an external power cable for continuous power supply.
Specifications
| Feature | Detail |
|---|---|
| Model | ZJLCD-BT01 |
| Brand | SPABOY |
| Display Type | LCD Digital Display |
| Voltage | 5 Volts (DC) |
| Material | PVC |
| Pipe Sizes | 1", 1-1/2", 2", 2-1/2", 3" (depending on variant) |
| Application | Farm/Garden Irrigation, Industrial Flow Measurement |
Setup and Installation
Proper installation is crucial for accurate readings and long-term performance. Follow these steps carefully:
- Choose Location: Select a section of pipe where the flow is stable and free from turbulence. Ensure there is sufficient straight pipe length before and after the meter (typically 10x diameter upstream and 5x diameter downstream).
- Prepare Piping: Turn off the water supply and drain the pipe section where the flow meter will be installed. Cut the pipe to the appropriate length to accommodate the flow meter.
- Install Meter: Insert the flow meter into the pipe, ensuring the flow direction arrow on the meter body aligns with the direction of water flow. Use appropriate PVC cement or threading tape for a watertight seal, depending on your pipe type and meter connections.
- Power Connection:
- Battery Powered Models: Ensure batteries are correctly inserted into the battery compartment.
- Wired Models: Connect the 5V DC power supply wires according to the color coding (typically red for positive, black for negative). Ensure connections are secure and insulated.
- Leak Check: Slowly restore water pressure to the system and check for any leaks around the flow meter connections. Tighten or re-seal as necessary.
Operating Instructions
The ZJLCD-BT01 features a simple interface for monitoring flow and total volume.
- Display Readout: The LCD screen typically displays the instantaneous flow rate (e.g., L/min, GPM) on the upper line and the total accumulated volume (e.g., Liters, Gallons) on the lower line.
- SET Button: Press the SET button to cycle through different display modes or to enter calibration/setting mode (refer to advanced settings for calibration).
- CLEAR Button: Press the CLEAR button to reset the accumulated volume to zero. Hold the button for a few seconds to confirm the reset.
- Unit Conversion: Some models may allow unit conversion (e.g., Liters to Gallons). Consult the specific model's advanced settings if this feature is available.
Maintenance
Regular maintenance ensures the accuracy and longevity of your flow meter.
- Cleaning: Periodically inspect the flow meter for any debris or sediment buildup, especially if used with unfiltered water. If necessary, remove the meter and gently clean the turbine impeller and internal passages.
- Battery Replacement: For battery-powered models, replace batteries when the low battery indicator appears on the LCD, or if the display becomes dim. Use the recommended battery type (e.g., AAA, AA).
- Leak Inspection: Regularly check all connections for leaks. Address any leaks promptly to prevent water damage and ensure accurate readings.
- Winterization: In freezing climates, ensure the flow meter is drained and protected from freezing temperatures to prevent damage to the PVC body and internal components.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No display/Display is dim | Dead or low batteries (battery models); No power supply (wired models); Loose power connection. | Replace batteries; Check power supply and connections; Ensure proper voltage (5V DC). |
| Inaccurate readings | Air in the line; Debris in the meter; Incorrect installation direction; Turbulence in flow. | Purge air from the system; Clean the meter; Verify flow direction arrow; Ensure sufficient straight pipe length. |
| Flow reading stuck at zero | No flow; Impeller jammed by debris; Sensor malfunction. | Verify water flow; Inspect and clean impeller; Contact support if issue persists. |
| Leaks at connections | Improper sealing; Damaged threads/gaskets. | Re-seal connections with appropriate sealant/tape; Replace damaged components. |
Warranty and Support
SPABOY products are designed for reliability and performance. For warranty information or technical support, please refer to the contact details provided with your purchase or visit the official SPABOY website.
Please retain your proof of purchase for warranty claims.
Related Documents - ZJLCD-BT01
![]() |
ZY-BT01 Bluetooth Module Instructions and FCC Compliance Instructions for the ZY-BT01 Bluetooth module, including setup, operation, and FCC compliance information regarding interference and radiation exposure. |
![]() |
EdgeSense Installation Manual - SES imagotag This document provides a comprehensive guide for installing and setting up the EdgeSense Electronic Shelf Label system by SES imagotag. It details component identification, hardware installation steps, power unit insertion, display connection, battery safety precautions, and FCC certifications. |
![]() |
Mzeada AZ-BT01 Yonle TWS Wireless Earbuds User Manual and Specifications Detailed information on the Mzeada AZ-BT01 Yonle TWS Wireless Earbuds, including product information, controls, earphone operation instructions, and FCC compliance statement. |
![]() |
Novostella LED Strip Light User Guide Comprehensive user guide for Novostella LED Strip Lights (NTS51/NTS101-RGB), covering product introduction, safety precautions, features, specifications, connection, operation, maintenance, and troubleshooting. |
![]() |
Franklin BT01 PRO Mini Bluetooth Speaker User Manual Comprehensive user manual for the Franklin BT01 PRO Mini Bluetooth Speaker, covering charging, Bluetooth pairing, stereo mode, mode switching, specifications, and FCC compliance. |
![]() |
AW-BT01 Bluetooth Car Charger: User Manual, Features, and Specifications User manual for the AW-BT01 Bluetooth car charger, detailing its features, button and port distribution, setup instructions, hands-free calling, device charging capabilities, and technical specifications. Includes FCC compliance information. |





