1. Introduction
The I TECH MAG 2000 is a low-frequency magnetotherapy device designed for home use. It features two independent channels and 35 pre-set programs, offering adjustable intensity up to 150 Gauss per channel. This device is intended to provide magnetotherapy treatments as prescribed by a healthcare professional. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your MAG 2000 device.
2. Important Safety Information
Read all instructions carefully before using the device. Failure to follow safety guidelines may result in injury or device malfunction.
- Consult a healthcare professional before starting any magnetotherapy treatment.
- Do not use this device if you have a pacemaker, are pregnant, or have any metallic implants unless specifically advised by a doctor.
- Keep the device away from strong magnetic fields and electronic equipment that may be sensitive to magnetic interference.
- Ensure the power adapter is correctly connected and the device is placed on a stable surface during use.
- Do not immerse the device or its accessories in water.
- Keep out of reach of children.
- If you experience any discomfort or adverse reactions during treatment, discontinue use immediately and consult your doctor.
3. Package Contents
Verify that all items are present in the package:
- I TECH MAG 2000 Magnetotherapy Device
- Elastic band with 3 solenoids
- Carrying bag
- Power adapter
- User Manual (this document)

Image: The I TECH MAG 2000 device with its included accessories, including the elastic band and carrying bag.
4. Setup
4.1. Device Overview

Image: Front view of the MAG 2000 device, showing the display and control buttons.

Image: Back view of the MAG 2000 device, showing product labels and ventilation.
4.2. Connecting the Power Adapter
- Locate the power input port on the side of the MAG 2000 device.
- Connect the power adapter cable to the device's power input port.
- Plug the power adapter into a suitable electrical outlet.

Image: Close-up view of the MAG 2000 device's side panel, showing the power input and applicator ports (CH1, CH2).
4.3. Attaching the Applicator (Elastic Band)
- Identify the elastic band with 3 solenoids.
- Connect the applicator cable to either the CH1 or CH2 port on the device. The device supports two independent channels for simultaneous application with additional applicators (sold separately).
- Ensure the connection is secure.

Image: The elastic band applicator with three integrated solenoids, ready for connection to the device.

Image: Close-up of the label on the elastic band applicator, showing model compatibility information.
5. Operating Instructions
5.1. Powering On/Off
- To power on the device, press the ON/OFF button located on the side of the unit. The display will illuminate.
- To power off, press and hold the ON/OFF button until the display turns off.
5.2. Program Selection
The MAG 2000 offers 35 pre-set programs for various therapeutic needs. Consult your healthcare professional for the appropriate program for your condition.
- After powering on, use the Up and Down arrow buttons to navigate through the available programs.
- The program number and a brief description will be shown on the display.
- Press the OK button to select a program.
5.3. Intensity Adjustment
The intensity can be adjusted up to 150 Gauss per channel.
- Once a program is selected, the device may allow intensity adjustment.
- Use the Up and Down arrow buttons to increase or decrease the intensity.
- Confirm the desired intensity by pressing OK, or the program may start automatically after a few seconds.
5.4. Applying the Elastic Band
Position the elastic band with the solenoids directly over the treatment area. Ensure good contact with the skin or through a thin layer of clothing. The elastic nature of the band allows for secure placement on various body parts.
5.5. Starting and Ending Treatment
- After selecting the program and adjusting intensity, the treatment will begin. The display will show the remaining treatment time.
- The device will automatically stop at the end of the program.
- You can manually stop a treatment at any time by pressing the ON/OFF button.
6. Maintenance
6.1. Cleaning the Device
- Always disconnect the device from the power outlet before cleaning.
- Wipe the main unit with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Ensure no liquid enters the device openings.
6.2. Cleaning the Applicator
The fabric cover of the elastic band can be cleaned. Refer to the specific instructions in the full user manual for detaching and reattaching the solenoids for washing.
6.3. Storage
Store the device and its accessories in the provided carrying bag in a cool, dry place, away from direct sunlight and extreme temperatures. Ensure cables are not tightly wound or kinked.

Image: The black carrying bag provided for storing and transporting the MAG 2000 device and its accessories.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | Power adapter not connected or faulty; power outlet issue. | Check power adapter connection. Try a different power outlet. Ensure the ON/OFF switch is in the 'ON' position. |
| No magnetic field detected from applicator. | Applicator not connected correctly; program not started; faulty applicator. | Ensure applicator cable is securely plugged into CH1/CH2. Start a program. If issues persist, contact support. |
| Display shows an error message. | Internal device error. | Turn off the device, wait 30 seconds, then turn it back on. If the error persists, note the error code and contact customer support. |
| Solenoids feel warm during use. | Normal operation for prolonged use. | This can be normal. If the heat becomes uncomfortable, place a thin cloth between the applicator and skin, or reduce treatment duration. If excessive, discontinue use and consult support. |
8. Specifications
| Model Name | MAG 2000 |
| Brand | I TECH |
| Channels | 2 independent channels |
| Programs | 35 pre-set programs |
| Intensity | Up to 150 Gauss per channel |
| Power Source | Wired (with electrical cable) |
| Dimensions (L x W x H) | 17L x 10l x 5H cm |
| Color | Black |
| Product Class | Professional |
| GTIN / UPC | 797142704766 |
| Manufacturer | I.A.C.E.R. SRL |
9. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the official I TECH website or contact your local distributor. You can also visit the I TECH Brand Store on Amazon for additional resources.
Official documents such as the Certificate of Conformity (PDF) and additional user manuals (e.g., User Manual (PDF), User Manual (PDF)) are available for download.