1. Introduction
This manual provides comprehensive instructions for the BN-LINK CP-U208D 24-Hour Mechanical Dual Outlet Timer. This device is designed to automate the on/off cycles of electrical appliances, offering convenience and potential energy savings. Please read this manual thoroughly before use to ensure proper operation and safety.
2. Important Safety Information
- For indoor use only. Do not expose to water or moisture.
- Do not exceed the electrical ratings of 125VAC, 60 Hz, 1875W, 15A (Resistive/Tungsten), and 1/2HP.
- Ensure the timer is securely plugged into a grounded outlet.
- Do not use with appliances that could cause a hazardous condition if left unattended, such as heating appliances without automatic shut-off.
- Keep out of reach of children.
- Do not disassemble or attempt to repair the unit. Refer to qualified service personnel.
3. Product Overview
The BN-LINK CP-U208D timer features a mechanical dial for setting schedules and dual grounded outlets for connecting two devices simultaneously. It includes a bypass switch for manual control.

Figure 1: BN-LINK CP-U208D Mechanical Dual Outlet Timer
Components:
- 24-Hour Dial: Displays time in 30-minute increments.
- Program Pins: Small segments around the dial. Each segment represents 30 minutes.
- Current Time Indicator: An arrow pointing to the current time on the dial.
- Dual Grounded Outlets: Two 3-prong outlets for connecting appliances.
- Bypass Switch (ON/TIMER/OFF): Allows manual control or timer activation.
4. Setup Instructions
Step 1: Set ON/OFF Times
The timer dial has 48 pins, each representing a 30-minute interval. To set your desired ON/OFF schedule:
- Push the pins DOWN for the periods you want the connected appliance to be ON.
- Leave the pins UP for the periods you want the connected appliance to be OFF.
The timer comes with all pins initially in the DOWN position. Pull up the pins for the times you want the device to be off.

Figure 2: Setting ON/OFF Times
Step 2: Set Current Time
Rotate the entire dial clockwise until the current time aligns with the arrow labeled 'Current Time' or 'Time Now'. Ensure you distinguish between AM and PM hours.
Step 3: Set Bypass Switch
Locate the switch on the side of the timer. Set it to the 'TIMER' position (represented by a clock icon) for the programmed schedule to activate. You can also set it to 'ON' for continuous power or 'OFF' to cut power completely, overriding the timer function.

Figure 3: Complete Setup Steps
Step 4: Plug in Appliances
Plug the BN-LINK timer into a standard 3-prong grounded wall outlet. Then, plug your appliances into the dual grounded outlets on the timer.
5. Operating the Timer
Once the timer is set and the bypass switch is in the 'TIMER' position, the dial will continuously rotate, activating and deactivating connected appliances according to your programmed schedule. The schedule will repeat daily without needing to be reset.
Manual Override
To temporarily override the programmed schedule, use the bypass switch:
- Set to 'ON' for continuous power to the connected devices.
- Set to 'OFF' to cut power to the connected devices.
- Return to 'TIMER' to resume the programmed schedule.
6. Recommended Applications
The BN-LINK CP-U208D timer is versatile and suitable for various indoor appliances, helping to automate your home and save energy.

Figure 4: Applicable Appliances
- Indoor Lighting (lamps, holiday lights)
- Fans
- Coffee Machines
- Grow Lights
- Aquarium Pumps
- Humidifiers

Figure 5: Timer in Various Home Settings

Figure 6: Space-Saving Design
7. Product Specifications
| Specification | Value |
|---|---|
| Model Number | CP-U208D |
| Voltage | 125VAC |
| Frequency | 60 Hz |
| Max Load (Resistive & Tungsten) | 1875W, 15A |
| Motor Rating | 1/2HP |
| Number of Settings | 48 (30-minute intervals) |
| Dimensions (D x W x H) | 2.6"D x 1.61"W x 3.15"H |
| Material | Polycarbonate |
| Color | White |
| Item Weight | 5.6 ounces |
8. Troubleshooting
Timer Not Turning On/Off at Programmed Times:
- Check Pins: Ensure pins are correctly pushed DOWN for ON times and UP for OFF times.
- Verify Current Time: Make sure the dial is rotated so the current time aligns with the 'Current Time' arrow.
- Bypass Switch Position: Confirm the side switch is set to the 'TIMER' position (clock icon).
- Power Supply: Ensure the timer is securely plugged into a live, functioning wall outlet.
Timer Runs Continuously (Does Not Turn Off):
- Bypass Switch: Check if the bypass switch is accidentally set to 'ON'.
- Pins: All pins might be pushed down. Pull up pins for desired OFF periods.
Timer Makes a Low Humming Noise:
A slight humming sound is normal for mechanical timers as the internal motor operates. If the noise is excessively loud or unusual, discontinue use and contact customer support.
9. Warranty and Customer Support
The BN-LINK CP-U208D 24-Hour Mechanical Dual Outlet Timer is backed by a 12-month warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use.
For technical assistance, warranty claims, or any questions regarding your product, please contact BN-LINK professional customer service. Refer to the product packaging or the BN-LINK official website for current contact information.