Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Leviton 2nd Generation Smart GFPE (Ground Fault Protection of Equipment) Branch Circuit Breaker, Model LB260-EST. This smart circuit breaker features remote control capabilities and plug-on installation, supporting both 120/208 VAC and 120/240 VAC applications. It is designed to integrate with the My Leviton app for enhanced energy management and safety features.

Safety Information

WARNING: Risk of electric shock. Installation and servicing of this product must be performed by a qualified electrician. Ensure power is disconnected at the main service panel before installation or maintenance. Failure to follow these instructions may result in serious injury or death.

  • Always turn off power at the main circuit breaker before working on electrical circuits.
  • Use appropriate personal protective equipment (PPE).
  • Verify all connections are secure and correctly wired according to local and national electrical codes.
  • Do not operate the circuit breaker if it appears damaged.
  • This device is intended for use with the Leviton Load Center only.

What's in the Box

Your package should contain the following items:

  • 1 x Leviton 2nd Gen Smart Circuit Breaker (Model LB260-EST)
  • 1 x Installation Instructions (this manual)

Setup and Installation

The Leviton LB260-EST Smart Circuit Breaker is designed for plug-on installation within a Leviton Load Center. A Whole Home Energy Monitor (LWHEM) is required for smart functionality.

  1. Prepare the Load Center: Ensure all power to the Leviton Load Center is OFF at the main disconnect.
  2. Wire the Load Center: The Leviton Load Center's design allows for branch phase and neutral connections to be made directly on the panel. Wires can be neatly landed at rough-in without any circuit breakers present, simplifying the wiring process.
  3. Install the Circuit Breaker: Once wiring is complete, align the LB260-EST circuit breaker with the appropriate slot in the Leviton Load Center. Firmly push the breaker into place until it clicks, ensuring a secure plug-on connection. No additional wiring is required for the breaker itself once the panel is wired.
  4. Restore Power: After all circuit breakers are installed and the panel cover is secured, restore power to the main service panel.
  5. My Leviton App Integration: Download the My Leviton app from your device's app store. Follow the in-app instructions to connect your Leviton Load Center and LB260-EST Smart Circuit Breaker to your home network. This step requires a Leviton Whole Home Energy Monitor (LWHEM).
Leviton LB260-EST 2nd Gen Smart GFPE Circuit Breaker
Figure 1: Front view of the Leviton LB260-EST 2nd Gen Smart GFPE Circuit Breaker. This image shows the ON/OFF/TEST switch and the GFPE indicator.
Side view of Leviton LB260-EST Smart Circuit Breaker
Figure 2: Side view of the Leviton LB260-EST Smart Circuit Breaker, illustrating its compact design for seamless integration into the load center.

Operating Instructions

Manual Operation

  • Turning ON: Push the switch lever to the "ON" position.
  • Turning OFF: Push the switch lever to the "OFF" position.
  • Testing GFPE Function: Press the "TEST" button on the breaker. The breaker should trip to the "OFF" position, indicating the GFPE function is working correctly. Reset by pushing the lever fully to "OFF" then to "ON".

Smart Features (via My Leviton App)

With the My Leviton app and a Whole Home Energy Monitor (LWHEM), you can access advanced features:

  • Remote Control: Remotely turn the LB260-EST circuit breaker ON or OFF from anywhere using the My Leviton app.
  • Circuit Scheduling: Set up custom schedules for your circuits based on time and day to optimize energy usage and save power.
  • Energy Monitoring: Gain insightful data on home energy consumption, allowing you to track usage patterns and identify areas for efficiency improvements.
  • Electrical Anomaly Notifications: Receive alerts for unusual electrical activity, enhancing safety and allowing for prompt action.

Video: Leviton Load Center Overview. This video demonstrates the features and benefits of the Leviton Load Center, including the easy installation of smart circuit breakers and smart home integration for energy management.

Maintenance

The Leviton LB260-EST circuit breaker is designed for minimal maintenance. Regular checks can help ensure continued safe operation:

  • Monthly GFPE Test: Press the "TEST" button on the circuit breaker monthly to ensure the Ground Fault Protection of Equipment (GFPE) function is operational. If the breaker does not trip, it should be replaced by a qualified electrician.
  • Visual Inspection: Periodically inspect the circuit breaker for any signs of physical damage, discoloration, or loose connections. If any issues are observed, contact a qualified electrician.
  • Cleaning: Keep the circuit breaker and surrounding area clean and free of dust and debris. Use a dry cloth for cleaning; do not use liquids or abrasive cleaners.

Troubleshooting

If you experience issues with your Leviton LB260-EST Smart Circuit Breaker, consider the following:

  • Breaker Trips: If the breaker trips, it indicates a ground fault or an overload condition. Disconnect appliances or devices on the affected circuit and attempt to reset the breaker by pushing the lever fully to "OFF" then to "ON". If it trips again immediately, there may be a persistent fault or overload. Consult a qualified electrician.
  • No Power to Circuit: Ensure the breaker is in the "ON" position. If it is, check the main service panel for any tripped main breakers. If power is still not restored, contact a qualified electrician.
  • App Connectivity Issues:
    • Ensure your home Wi-Fi network is active and the signal is strong near the Leviton Load Center.
    • Verify that the Whole Home Energy Monitor (LWHEM) is properly installed and connected.
    • Check the My Leviton app for any error messages or updates.
    • Restart your Wi-Fi router and the Whole Home Energy Monitor.
  • Remote Control Not Working: Confirm that the circuit breaker is connected to the My Leviton app and your home network. Check for app updates.

For persistent issues, contact Leviton Customer Support or a qualified electrician.

Specifications

FeatureSpecification
Model NumberLB260-EST
Current Rating60 Amps
Voltage120/240-Volt and 120/208-Volt AC
Number of Poles2
Interrupt Rating10kA
Circuit Breaker TypeGFPE (Ground Fault Protection of Equipment, 30 mA)
Mounting TypeSnap-In Mount (Plug-On)
Product Dimensions (D x W x H)3.1" x 2" x 3.9"
Item Weight1.23 pounds
Smart Home CompatibilitySmart Home Compatible (requires My Leviton app & LWHEM)

Warranty and Support

For detailed warranty information, please refer to the official Leviton website or contact Leviton Customer Support. Keep your purchase receipt as proof of purchase.

Leviton Customer Support:

  • Website: Visit the official Leviton website for product registration, FAQs, and support resources.
  • Phone: Refer to the contact information provided on the Leviton website or product packaging for technical assistance.

Always ensure you are consulting official Leviton resources for the most accurate and up-to-date information.

Related Documents - LB260-EST

PreviewLeviton Load Center Enclosure Installation Instructions
Detailed installation instructions for Leviton Load Center Enclosures, models LP2xx, LP3xx, LP4xx, and LP6xx. Covers safety, knockout removal, mounting, wiring, branch circuit breaker installation, and cover fitting.
PreviewMy Leviton App Guide: Smart Home Control with Decora Smart Wi-Fi and Load Centers
A comprehensive guide to using the My Leviton app for smart home automation, covering Decora Smart Wi-Fi devices and Leviton Load Centers. Learn to set up residences, add devices, create schedules and activities, customize settings, monitor energy usage, and utilize advanced features like smart anomaly detection and visual remote assistance.
PreviewLeviton GFCI Receptacle Installation and Testing Guide
A comprehensive guide on how to install and test a Leviton SmartLock Pro GFCI Receptacle, including wiring instructions, safety precautions, and troubleshooting tips.
PreviewLeviton Load Center Phase Maps Installation Guide
This guide provides phase map illustrations to simplify the installation of the Leviton Whole Home Energy Monitor (LWHEM). It details where to terminate power wires and mount the Smart Mains Metering Accessory CTs for monitoring whole-home energy consumption.
PreviewLeviton VIZIØ6-1L Incandescent Dimmer Installation Instructions
Comprehensive installation guide for the Leviton VIZIØ6-1L Incandescent Dimmer, covering single-pole and 3-way multi-location setups, wiring diagrams, operation, advanced programming, troubleshooting, and warranty information.
PreviewLeviton IP710-LF Fluorescent and LED Fixture Slide Dimmer Installation Guide
Comprehensive installation instructions for the Leviton IP710-LF Single Pole or 3-Way Fluorescent and LED Fixture Slide Dimmer. Learn how to safely install, wire, and operate your dimmer for 0-10V dimmable fixtures.